SMC Corporation of America
Elite Part Number Search
Search Results "PSH-RT-M-01-W"

Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: SI Unit Only, Fixed Unit: kPa, MPa, Piping Specification: R1/8, Lead Wire: Lead Wire w/Connector, 5-core, 2m Lead Wire w/Waterproof Cover, Bracket: -, Operation Manual: -

Rated Vacuum Range: -100.0 to 100.0 kPa, Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: SI Unit Only, Piping Specification: R1/8, Lead Wire: Lead Wire w/Connector, 5-core, 2m Lead Wire w/Waterproof Cover, Bracket: -, Operation Manual: -

Response t me 1.Zns ' Shock resistance 300 m/s'(reed swrtch) 1000 m/s'(solid state s',vitch) Flange & Auto Switch Mounting Brqcket Weights NCDRBIOWI0.15.20.30 Rotation Time Setting Fitting Loeation And. Rotation Of Auto Switch luto Swilch 9(r, 160' Ewn a small torque generated by the rotary actuator. due to inertia, can cause qamage.

single flat (Size: 40) M Grommet / Lead wire: 1 m W L Grommet / Lead wire: 3 m CN Connector / Without lead wire C Connector / Lead wire: 0.5 m Rotation angele Number of auto switches CL Connector / Lead wire: 3 m 90 90 Nil 2 Z* Grommet / Lead wire: 5 m 180 180 S 1 * The 5m lead wire is produced upon receipt of order. * Connectors are only available for the R73, R80, and 270 270 T79. **

IDX-OM-W022-A PRODUCT NAME Refrigerated Air Dryer MODEL / Series IDU8E-10(-C,K,L,M,R,S,T) IDU8E-20(-C,K,L,M,R,T) IDU11E-10(-C,K,L,M,R,S,T) IDU11E-20(-C,K,L,M,R,T) IDU15E1-10(-C,K,L,M,R,S,T) IDU15E1-20(-C,K,L,M,R,T) IDU8E-23(-C,K,L,R,T,V) IDU11E-23(-C,K,L,R,T,V) IDU15E1-23(-C,K,L,R,T,V) Please read this manual prior of using the air dryer. Keep the manual readily available for reference.

If it must be used under such conditions due to unavoidable circumstances, contact SMC beforehand. w Do not use it with anything other than dry air (such as air containing moisture).

ORIENTATION w Make sure to install this product on horizontal piping.

Colour on the feed holes Cable colour Signal Cable O.D. 4.0 to 8.0 mm Electric wire cross section (Twist line) AWG26 to 22 YE=Yellow or OGWH=Orange/ White 1 Orange/ White TD+ WH=White or GNWH=Green/ White 2 Green/ White RD+ 3 Orange OG=Orange TD4 Green BU=Blue or GN=Green RD-29No.EX-OMV0023-A (3) Cable with communication connector Part number: EX9-AC 01 0EN-PSRJ Cable length (L) 01 1000 [

N.O. 101.2 kPa to 0.2 VPA344 544 744 Pilot pressure (MPa) Ambient and fluid temperature (C) Lubrication Mounting orientation Impact/Vibration resistance (m/s2) Note) Same as operating pressure (Min. 0.2 MPa) 10 to 50C (No freezing. Refer to page 5-11-4.) Not required (Use turbine oil Class 1 lSO VG32, if lubricated.)

Body Size: 20, Backflow: K (w/Backflow Function), Thread: Rc, IN Port Size: 01 (1/8), OUT Port Size: 01 (1/8), Options: M (Round type pressure gauge, with color zone), Set Pressure: 0.05 TO 0.85 MPa Setting, Exhaust Mechanism: Relieving Type, Knob: Downward, Pressure Unit: Unit on Product Label: MPa, Pressure Gauge in SI Units: MPa

Body Size: 20, Backflow: K (w/Backflow Function), Thread: F (G), IN Port Size: 01 (1/8), OUT Port Size: 01 (1/8), Options: M (Round type pressure gauge, with color zone), Set Pressure: 0.05 TO 0.85 MPa Setting, Exhaust Mechanism: Relieving Type, Knob: Downward, Pressure Unit: Unit on Product Label: MPa, Pressure Gauge in SI Units: MPa

Body Size: 20, Backflow: K (w/Backflow Function), Thread: N (NPT), IN Port Size: 01 (1/8), OUT Port Size: 01 (1/8), Options: M (Round type pressure gauge, with color zone), Set Pressure: 0.05 TO 0.85 MPa Setting, Exhaust Mechanism: Relieving Type, Knob: Downward, Pressure Unit: Z (Unit on Product Label: psi, Pressure Gauge: MPa/psi Dual Scale)

Symbol Nil N F Option Option Symbol Applicable actuation Built-in solenoid valve Air Operated PB1013A Air operated Port size Port size 1/8 Nil B N None With foot With silencer Symbol 01 When option is more than one, suffix in alphabetical order.

T 04 06 08 10 12 4 6 8 10 12 VMG Construction Description Material Component Parts No. q w e r t y u i o !0 !

Furthermore, if the cable length exceeds 5 m, then it will decrease by up to 10% for every additional 5 m.(If cable length is 15m: Maximum 20% reduction.)

PA02] 0 0 Select a regenerative option. 00: Regenerative option is not used. 00: 100 W 0.2 kW 7 kW 11 kW 22 kW 01: FR-BU2FR-RC FR-CV 02: MR-RB032 03: MR-RB12 04: MR-RB32 05: MR-RB30 06: MR-RB50 () 08: MR-RB31 09: MR-RB51 () 0B: MR-RB3N 0C: MR-RB5N ( ) FA: 11 kW 22 kW UP For drivers of LECSN-T5, do not use a regenerative resistor.

Response t me 1.Zns ' Shock resistance 300 m/s'(reed swrtch) 1000 m/s'(solid state s',vitch) Flange & Auto Switch Mounting Brqcket Weights NCDRBIOWI0.15.20.30 Rotation Time Setting Fitting Loeation And. Rotation Of Auto Switch luto Swilch 9(r, 160' Ewn a small torque generated by the rotary actuator. due to inertia, can cause qamage.

Example) AW30K-03BE-1N-B B AW 30 03 BE K q w e r t y q Body size 20 30 40 60 Symbol Description w With backflow function Nil Without backflow function K Note 1) With backflow function + e Pipe thread type Nil Rc N Note 2) NPT F Note 3) G + 01 1/8 02 1/4 03 3/8 04 1/2 06 3/4 r Port size 10 1 + a Mounting Nil Without mounting option B Note 5) With bracket H With set nut (for panel mount