SMC Corporation of America
Elite Part Number Search
Search Results "VEX3502-10N3DZ-B"

Max. Suction Flow Rate: Max. Suction Flow Rate: 300 L/min (ANR, Supply Pressure: 0.50 MPa, Vacuum (2/V) Port Size/Supply (1/P) Port Tubing O.D: 06 [Vacuum: Rc3/4; Supply: 8 (Metric)], Exhaust Method: Silencer Exhaust, Supply Valve/Release Valve Combination: w/o Valve, Rated Voltage: None, Electrical Entry: None, Light/Surge Voltage Supprressor: None, Manual Override: Non-locking Push Type

Max. Suction Flow Rate: Max. Suction Flow Rate: 300 L/min (ANR, Supply Pressure: 0.50 MPa, Vacuum (2/V) Port Size/Supply (1/P) Port Tubing O.D: F04 [Vacuum: 2 x G1/2 (Branch Spec.); Supply: 8 (Metric)], Exhaust Method: Silencer Exhaust, Supply Valve/Release Valve Combination: w/o Valve, Rated Voltage: None, Electrical Entry: None, Light/Surge Voltage Supprressor: None, Manual Override: Non-locking

Stations: 8 Stations, SUP Port Thread: Rc(PT), Port Location: B [Port Location: Both Sides,Vacuum Supply(Ejector,External Vacuum):PV]

Stations: 7 Stations, SUP Port Thread: Rc(PT), Port Location: B [Port Location: Both Sides,Vacuum Supply(Ejector,External Vacuum):PV]

Stations: 2 Stations, SUP Port Thread: Rc(PT), Port Location: B [Port Location: Both Sides,Vacuum Supply(Ejector,External Vacuum):PV]

Stations: 3 Stations, SUP Port Thread: Rc(PT), Port Location: B [Port Location: Both Sides,Vacuum Supply(Ejector,External Vacuum):PV]

Stations: 4 Stations, SUP Port Thread: Rc(PT), Port Location: B [Port Location: Both Sides,Vacuum Supply(Ejector,External Vacuum):PV]

Stations: 6 Stations, SUP Port Thread: Rc(PT), Port Location: B [Port Location: Both Sides,Vacuum Supply(Ejector,External Vacuum):PV]

Stations: 5 Stations, SUP Port Thread: Rc(PT), Port Location: B [Port Location: Both Sides,Vacuum Supply(Ejector,External Vacuum):PV]

Type: for Air, Output Specification: NPN 4 Outputs, Unit Specification: With Unit Switch Function, Option 1: Front Protective Cover + Panel Mount, Option 2: -

Type: for Air, Output Specification: PNP 4 Outputs, Unit Specification: With Unit Switch Function, Option 1: Front Protective Cover + Panel Mount, Option 2: -

Type: for Deionized Water and Chemicals, Output Specification: PNP 4 Outputs, Unit Specification: With Unit Switch Function, Option 1: Front Protective Cover + Panel Mount, Option 2: -

Type: for Water, Output Specification: NPN 4 Outputs, Unit Specification: With Unit Switch Function, Option 1: Front Protective Cover + Panel Mount, Option 2: -

Type: for Water, Output Specification: PNP 4 Outputs, Unit Specification: With Unit Switch Function, Option 1: Front Protective Cover + Panel Mount, Option 2: -

Type: for Deionized Water and Chemicals, Output Specification: NPN 4 Outputs, Unit Specification: With Unit Switch Function, Option 1: Front Protective Cover + Panel Mount, Option 2: -

Output Specification: PNP output, Unit: Unit Change Function, Option 1: Panel Mount + Front Protective Cover, Option 2: -

Output Specification: NPN output, Unit: Unit Change Function, Option 1: Panel Mount + Front Protective Cover, Option 2: -

Pressure Specifications: 2 [-10 to 100kPa (for low pressure)], One-touch Fitting Type: None, Option, Case Holder: With PPA-B, Unit Specification: -

Calculate the moment of inertia for A and B separately as shown in the figures on the right. A part B part Procedure Calculation Calculation example 1. Check the operating conditions, dimensions of attachment, etc. Operating model: MHY2-16D Opening time: 0.15 s a = 40 (mm) b = 7 (mm) c = 8 (mm) d = 5 (mm) e = 10 (mm) f = 12 (mm) A part a b c B part e f d 2.