Bolts Size Belt Belt tension Part number (N) LEF16 LE-D-6-1 9.8 pull LEF25 LE-D-6-2 19.6 LEF32 LE-D-6-3 49.0 LEF40 LE-D-6-4 98.1 Bolts Size Tightening torque 6.Motor cover is installed. (Only "With motor cover") (Nm) M2.5 0.3610% M3 0.6310% M4 1.510% M5 310% The fingernail of "Grommet" is inserted in the hole of "Pulley box". Grommet 43 - 7.
D-F9, D-F9W 5 4 D-Z7, Z80 9 9 11 A B D-Y59, Y7P D-Y7W 6 6 6 Switches cannot be mounted in some cases.
Arrangement (Right valve station which is looked from valve side is first station.) 06 B Both sides 6 Viewed from the front side of valve unit, confirm the port location on the right and/or left side. 1 1 1 station only 1 station only 6 6 6 stations only 6 stations only All stations A All stations A If more than one spacer is required, specify all spacers.
9 6 9 6 9 6 9 6 9 IN IN IN MPa MPa MPa MPa MPa Right Left Right Bracket DIN rail mounting bracket DIN rail mounting bracket Stations 1 Stations 1 Stations 1 2 3 IISA2NSR-1B1 set (1 station manifold part number) ISA2-GE41P1 set (Air catch sensor part number) IISA2NSR-3D1 set (3 stations manifold part number) ISA2-HE41P 3 sets (Air catch sensor part number) Prefix the part number of the air
D-F9, D-F9W 5 4 D-Z7, Z80 9 9 11 A B D-Y59, Y7P D-Y7W 6 6 6 Switches cannot be mounted in some cases.
Rated voltage 5 6 24 VDC 12 VDC Note 1) Light/surge voltage suppressor is built-in.
7 units 6 units 7 units 8 units 8 units 4 units 5 units 5 units 4 units 6 units 6 units 7 units 7 units 3 units Wiring/Piping Connectable number of ionizers (IZS42) with transition wiring (without external sensor) Warning 1.
I ':"1 6 65 274 1 7 7 1 7 7 6 52 55 -r5 loo . 6 . 202 202 6 8 65 320 227 227 6 47 75 litzs . 70 345 252 252 6 47 150 6 8 370 277 2 7 7 r 1 65 T-slot A dimensions T-slot B dimensions $unies tX$ tilo To 0[dEl' tlect|'ic Acl||at0 AC Servo Motor 100vAc TS45O1N -rslsotl I Nole 1) l Applicable Applicable TarnaFwa Sek I 2OOVAC TS45O1N AppLicable L Applicable 3 -.'
: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com D-H7 D-G59F 5 5 5.5 6 7 7.5 8 7.5 D-B5/B6 BA -04 BA -05 BA -06 BA -08 BA -10 BA -32 BA -02 BA -01 CX D-G5NBL 35 40 45 45 45 40 50 45 D-G5/K5 D-B7/B8 BM1 -01 BM1 -02 BM1 -32 BM1 -04 BM1 -05 BM1 -06 Since this is a guideline including hysteresis, not meant to be guaranteed.
Code psig/bar unit MPa unit No code 0 V3 1 2 10 40 No gauge port e e 4PL 5PC No pressure gauge (Connections: 1/4 inch NPT) Sample Order Number Port -30 in.Hg to 30 psig -30 in.Hg to 100 psig 0 to 200 psig 0 to 1000 psig 0 to 4000 psig -0.1 to 0.2 MPa -0.1 to 0.7 MPa 0 to 1.5 MPa 0 to 7 MPa 0 to 28 MPa AK1410TS e q 6 6 6 6 w 6 6 6 6 r t qIN wOUT eExtra bottom port (Outlet) rGauge port (Inlet
7 8 9 10 11 12 13 40 and larger are the same as number 6.
for 6 Elbow top ported M5 threads Elbow bottom ported With One-touch fitting for 3.2 Elbow bottom ported With One-touch fitting for 4 Elbow bottom ported With One-touch fitting for 6 Elbow bottom ported M5 threads Elbow mixed port sizes Port size With One-touch fitting for 4 With One-touch fitting for 6 With One-touch fitting for 8 Mixed and with port plug Elbow top ported With One-touch
SOL.A 1 station 2 stations 3 stations 4 stations 1 () SOL.A 14 () SOL.A 2 () 1 SOL.A 14 15 () 2 SOL.A 15 3 () 3 4 5 6 7 8 9 10 11 12 13 5 stations 16 17 18 19 20 21 22 23 24 25 SOL.B 16 () SOL.A 4 () 6 stations SOL.B 17 () SOL.A 5 () 7 stations SOL.B 18 () SOL.A 6 () 8 stations SOL.B 19 () COM. 13 (+) Connector terminal no.
Refer to pages 17-6-3 to 17-6-10 for Safety Instructions and Solenoid Valve Precautions. Operating Environment Maintenance Warning Warning 1.
VQ4 VQ5 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Connector wiring diagram (mixed wiring) VQZ 6 A 4 A 3 A 1 A 5 B 2 B Output 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 VQD 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10 1 2
(mm) 6 tube M14 x 1 20 to 50 8 tube Ball joint rotation 15 Buffer Type Pad dia.
3 3 2 4 4 5 5 6 6 7 7 0 8 1 9 2 Reserved 3 Reserved 3 4 Reserved 5 Reserved 6 Reserved 7 Reserved 01 -63No.EX-OMS0026CN EDS PLC EX600 EDS PLC EX600 EDS ex600_sen3_4_v10.eds ex600_1.ico Logix Designer TM TMEX600 Rockwell Automation Logix Designer EDS Generic Ethernet Module 1EDS [Tools][EDS Hardware Installation Tool] [Option][Register an EDS file(s)][] -64No.EX-OMS0026CN
Q: 8 Model A B C D F H I J K P Q: 6 Q: 8 Y K P K P ZPT20F10-0-A14 ZPT40F10-0-A14 13 140 18.5 39 51.5 118 136.5 5 12.5 20 22 40 43 13 13 137 15.5 36 50 115 13 133.5 12.5 52.5 50 48.5 ZPT25F10-0-A14 ZPT50F10-0-A14 141 19.5 40 119 137.5 6 13.5 25 28 50 53 ZPT32F10-0-A14 135.5 16 36.5 115.5 134 13 32 35 49 Additional dimensions by stroke(mm) Additional dimensions by stroke(mm) K P Q: 6 Q: 8 K
47.0 2.35 01 59.7 Hastelloy is a registered trademark of Haynes International.