Reference Information . 41 8. 1 Checksum Calculation Procedure . 41 8. 2. Checksum Calculation Examples . 41 8. 3 Communication Response Time Guides . 41 8. 4 ASCII Code List. 42 3 LATCA Series Controller 1. Safety Instructions These safety instructions are intended to prevent hazardous situations and/or equipment damage.
M L K J H E t W1 W2 M 14 20 25 29 37 49 58 69 89 100 117 136 14.5 20.5 24.5 30.5 36.5 48.5 6 7 7 9 9 10 11 16 21 24 32 41 10 17 22.5 24.5 27 30 16 21 26 32 41 50 17 24 28 36 43 55 8 8 8 8 13 13 1/8" 1/4" 3/8" 1/2" 3/4" 1" LQ3P1A LQ3P2A LQ3P3A LQ3P4A LQ3P5A LQ3P6A 1/4 (E) (E) L Panel Aperture (K) Straight Union : LQ3U (mm) Inch Size H Model Tubing O.D.
range [mm] R OA OB PA PB Q S T U PC W X Y Without lock With lock Without lock With lock Motorless 25 15 to 100 8 37 38 15.4 8.2 28 46 92 1 15.4 123 173 145 195 51 101 to 400 LAT 32 20 to 100 10 37 38 15.4 8.2 28 60 118 1 15.9 123 173 150 200 61 101 to 500 LZ [mm] Body Bottom Tapped Size Stroke range [mm] MA MB MC MD MH ML MO MR XA XB LC3F2 15 to 39 24 32 50 M5 x 0.8 6.5 4 5 40 to 100 42 41
Weight (g) D-M9P(V) D-M9B(V) D-M9N(V) Auto switch model 0.5 m (Nil) 8 7 1 m (M) 14 13 Lead wire length 3 m (L) 41 38 5 m (Z) 68 63 Dimensions (mm) D-M9 D-M9V Mounting screw M2.5 x 4 L Slotted set screw (flat point) 500 (1000) (3000) (5000) Indicator light 2.6 3.95 Mounting screw M2.5 x 4 L Indicator light 2.8 Slotted set screw 2 7.5 0.3 22.8 2.6 15.9 4.6 2.8 2.6 19.5 2.6 6 Most sensitive
230 VAC (60 Hz) Three-phase 460 VAC (60 Hz) AMH AME Air flow capacity SCFM (m3/h [ANR]) Series Rated inlet condition Port size Outlet air pressure dew point Note) AMF 37F(2.8C) 45F(7.2C) 50F(10C) IDFB3E IDFB4E IDFB6E IDFB8E IDFB11E IDFB15E IDFB22E IDFB37E IDFB55E IDFB75E NPT3/8 10(17) 11(19) 12(20) ZFC NPT1/2 15(25) 16(27) 17(28) 25(43) 26(45) 28(47) SF 100F (37.8C) 100psi (0.7MPa) NPT3/4 41
Volume Double vane Single vane Vane type CRB2BW40-S CRB2BW10-D CRB2BW15-D CRB2BW20-D CRB2BW30-D CRB2BW40-D CRB2BW10-S CRB2BW15-S CRB2BW20-S CRB2BW30-S Model Rotation 90 180 270 90 180 270 180 270 180 270 180 270 90 100 90 100 90 100 90 100 90 100 90 90 90 1 (0.6) 1.5 (1.0) 4.8 (3.6) 11.3 (8.5) 25 (18.7) 1.2 1.5 2.9 3.7 6.1 7.9 15 20.2 31.5 41 1.0 1.1 2.6 2.7 5.6 5.7 14.4 14.5 33 34 Volume
A 152.5 154 B 52.5 54 E 52 64 I 69 86 J 5 7 M 40 50 N 5.5 6.6 O counterbore 9 depth 7 11 depth 8 T 44 56 Z 14 19 W 66 80 U 35 41 Bore size (mm) 40 50 Data Note 1) Dimensions without auto switch are the same as drawing above. Note 2) These figures show the dimensions when equipped with D-A73 or D-A80 auto switches.
5 Brass Spring seat i 6-3-40 41 41 Series CJ2K Air Cylinder: Non-rotating Rod Type Single Acting, Single Rod, Spring Return/Extend Single Acting, Spring Return: Basic Style (B) CJ2KB S Port location on head cover Bore size Stroke Piping port M5 x 0.8 Piping port M5 x 0.8 Mounting nut Rod end nut CJ1 CJP S + Stroke Rod section CJ2 Port location on head cover: Axial location (R) Z + Stroke
about the rod end nut and accessory brackets, refer to page 7-6-20. 7-4-10 11 Series CQS Compact Cylinder: Standard Type Double Acting, Single Rod Foot Style Foot style: CQSL/CDQSL B + Stroke Special cap bolt Standard stroke range (mm) Long stroke range (mm) Without auto switch With auto switch Without/With auto switch Long stroke Standard stroke Bore size (mm) LS B 20 20 29 29 A 32 32 41
Width across flats of attachment 3/8 24 mm 1/2 28 mm 3/4 35 mm 1 41 mm Ensure that the piping is tightened to the required torque. The tightening torque for connection threads is shown in the table below.
(1) Operation check by test drive . 41 (2) Operation check with the monitor . 41 5.4.1 Operation check by test drive. 41 (1) Operation check by test drive in easy mode . 41 (2) Operation check by test drive in normal mode . 43 5.4.2 Operation check with monitor . 45 (1) Operation check with monitor in easy mode . 45 (2) Operation check with monitor in normal mode . 46 6.
Supply port PD (mm) D FC GC 6 8 11 15 A B C EA EB FA FB FD FE FF FG GA GB GD 83 111 155 200 256 Model MIW8-8 MIW12-12 MIW20-20 MIW25-25 MIW32-32 M3 x 0.5 M3 x 0.5 M5 x 0.8 M6 x 1 22 34 43.5 58 73 2.6 3.3 5.1 6.8 8.6 9 12.5 16.5 20 24.5 28 37 54 71 80 4 4.5 6.5 10 12.5 7 9.5 12.5 17 22 16 21 29.5 40 47 15 19 25.5 37 51 34 44 64 84 95 18 23 28.5 41 55 57 26 35 48.5 66 87 6 (Effective depth
N) With front end lock: CBM2B Bore size -RN Stroke Manual release locking style (Additional symbol: L) With double end lock: CBM2B Bore size -WN Stroke With rod boot (mm) HN (MAX) Stroke range Symbol DL B2 D H2 HR B1 A Eh8 F I K MO NA P S H1 H NN AL G MM N ZZ Bore (mm) 20 25 32 40 0 0.033 0 0.033 0 0.033 0 0.039 1/8 1/8 1/8 1/4 Up to 300 7.5 8 15.5 13 26 5 8 22.3 34 M8 X 1.25 M20 X 1.5 41
If screws other than those specified are used, it may cause the switch to be damaged. 3 41 41 38 5 68 68 63 Auto Switch Dimensions Unit: mm Auto switch internal circuits D-M9 Mounting screw M2.5 x 4 Slotted set screw D-M9N D-M9B, N, P Common DC (+) Brown [Red] Indicator light 2.6 Switch main circuit Switch main circuit Switch main circuit OUT Black [White] 2.7 2.8 4 22 DC (-) Blue [Black]
Dimensions GC GC S + (2 x Stroke) Stroke B Stroke A ZZ + (2 x Stroke) ZZ + Stroke (A + B) S + Stroke (A + B) ZZ 262 320 320 S 200 244 244 GC 43 52 52 ZZ 231 235 262 S 180 180 200 Bore size (mm) 32 40 50 GC 36 38 41 Bore size (mm) 63 80 100 Bore size (mm) 32 40 50 63 80 100 GC 36 38 41 43 52 52 S 178 178 198 198 242 242 ZZ 272 280 314 314 386 386 NPT ports XC18 15 Dual stroke cylinder/single
C J G5-S Material: Carbon steel Material: Polyurethane (mm) (mm) (mm) CV MM A B M16 x 1.5 M20 x 1.5 M25 x 1.5 M30 x 1.5 M32 x 1.5 B 3.5 4.5 5 6 6.6 C 22 27 32 41 41 h1 25.4 31.2 37 47.3 47.3 C 4 8 8.3 11.3 13.1 h M16 x 1.5 M20 x 1.5 M25 x 1.5 M30 x 1.5 M32 x 1.5 MM B 6 6 6 6 6 C 22 27 32 41 41 Part no. Part no. Part no.
590 AMV 3/4 200 72 74 41 710 1 200 72 74 41 605 AMP 1 200 72 74 41 725 1 230 72 74 41 665 1 230 72 74 41 810 11/4 240 72 74 54 765 11/4 240 72 74 54 910 11/2 240 72 74 54 790 11/2 240 72 74 54 935 609 5.0 MPa 5.0 MPa Applications included air-blowing, charging fluid into a vessel, or discharging (Blow-molding equipment, etc.)
Return to origin . 41 8.1 Return to origin . 41 8.2 Positioning operation . 41 8.3 Pushing operation. 42 (1) Pushing operation is successfully performed. . 42 (2) Pushing operation is failed (pushing the air) . 42 (3) Movement of the work piece after the completion of the pushing process .. 42 8.4 Controller input signal response time . 43 8.5 Methods of interrupting operation . 43 9.
Piping . 41 5-7. Operating environment . 41 5-8. Lubrication . 41 6. Maintenance or inspection . 41 6-1. Maintenance or inspection . 41 6-2. Replacement part . 42 6-3. Maintenance . 42 1 - Safety Instructions These safety instructions are intended to prevent hazardous situations and/or equipment damage.
(mm) Rod end male threads a b c e f g h Bore size (mm) 20 11 15 M10 x 1.25 6 10 23 66 25 14 18 M12 x 1.25 6 12 26 71 32 21 25 M16 x 1.5 7 14 35 86 40 26 30 M20 x 1.5 7 19 40 95 50 31 35 M24 x 1.5 8 24 46 106 63 41 45 M30 x 1.5 9 30 58 125 80 56 60 M39 x 1.5 14 41 77 155 100 71 75 M48 x 1.5 21 50 101 197 7 Series CHKDB Auto Switch Specifications Auto Switches: Proper Mounting Positions and