proportional valve (VEP type) Current 5 (R1) 4 (A) 1(P) 2 (B) 3 (R2) IRV Simplifying circuit design Space-saving and piping work eliminated 2 (A) 1 (P) Selection of inlet pressure or atmosphere 3 (R) 5 (R1) 4 (A) VEX1 1(P) 2 (B) 3 (R2) SRH SRP SRF System Diagram ARX20 Power amplifier VEA25 VCHR Control circuit Voltage Current ITV 0 to 5 VDC 4 (A) IC 2 (B) PVQ Electro-pneumatic proportional
/4" 5/8" to 3/4" Weight, lbs (kg) 46.3 (21) 49.6 (22.5) 81.6 (37) Dimensions, LxWxH, in (mm) 18.2x6.1x9.1 (463x157x230) 18.2x6.1x9.1 (463x157x230) 22.4x8.1x11.4 (569x206x289) Pump with Explosion Proof Motor, 115V/208-230V, 60 Hz, 1 Phase, cUL Listed. 3046E-01 3086E-01 3166E-01
How to Order VHS 4 5 1 0 01 Paint color Nil X1 Standard color Handle, body: Red With locking holes Pressure relief 3 port valve Optional specifications Body size Flow direction: Right Left R 4 5 1/2 1 JIS Symbol (A) 2 Port size Double action 02 03 04 06 10 1/4 3/8 1/2 3/4 1 Thread type 3 (R) 1 (P) Nil F N Rc G NPT OSHA standard (Occupational Safety and Health Administration Department of
] 10 1/4,3/8 20 2000 6 10 1/4, 3/8 2500 7.5 =0.7 10 1/4, 3/8 0.5 3000 9 10 0.1 0.3 6 1/4,3/8 500 2.5 8 1/4, 3/8 1000 5 0 10 1/4, 3/8 1,000 2,000 3,000 25 1500 7.5 Maximum speed Vmax [mm/s] 10 1/4 2000 10 32 2500 3000 12.5 15 1/4 1/4 30 6 10 1/4, 3/8 =0.7 500 4 20 0.5 0.1 0.3 10 10 1/4, 3/8 32 1000 8 1500 2000 2500 3000 12 16 20 24 1/4,3/8 3/8 3/8 3/8 0 1,000 2,000 3,000 Maximum speed Vmax
OFF Note 1: ON/OFF 50 ms flashing Note 2: ON 200 ms single flash, OFF 1 s Note 3: ON/OFF 200 ms double flash, OFF 1 s Note 4: ON/OFF 200 ms triple flash, OFF 1 s Note 5: ON/OFF 200 ms flashing -15No.EX-OMV0023-A Switch setting The switches should only be set with the power supply turned off.
A3 A5 DC motor (cylinder size 3) DC motor (cylinder size 5) Option Cable for power supply terminal LC3F2 1 C1 02 1 CN1 Power Supply Terminal Table 2 3 1 Optional cable color Terminal Function Pin number Cable type Cable length 01 02 1 m 2 m Yellow/Green FG Frame ground 1 Cable for CN1 power supply terminal C1 Cable length 60 5 60 5 2 Brown DC (+) Driver power supply (+24 V) Cable for
CH4_OUT1 (Pink) DC(+) Sensor input: DC+ 1 to 5V DC() DC() (Blue) N.C. PSE201-(M) PNP open collector 5 outputs + Auto shift 1 input specification Supply pressure exceeds the maximum regulating pressure. Reduce/Increase supply pressure to within the regulating pressure range. DC(+) (Brown) DC(+) Sensor input: DC+ 1 to 5V 1.2k 7.3k DC() N.C.
function working, Response time is 500 ms, 1 s, 2 s or less Short circuit protection Short protection equipped Voltage output Output voltage: 1 to 5 V (within rated measurement range) Output impedance: Approx. 1 k Accuracy (to display value 25 oC) 1%F.S.
B AR20-B AR40-B AR25-B Differential pressure gauge GD40-2-01-X29 Y30(T)-A Y30(T)-A Y20(T)-A Y40(T)-A Spacer Y40(T)-A Y20(T)-A Fluid Compressed Air Range of operating conditions Inlet air pressure MPa 0.3 to 1.0 0.3 to 0.85 0.3 to 1.0 0.3 to 0.85 Inlet air temperature oC -5 to 55 -5 to 50 -5 to 55 -5 to 50 *Note1 Ambient temperature oC -5 to 55 -5 to 50 -5 to 55 -5 to 50 *Note1 Standard Performance
Applicable cylinder bore size (mm) Model Metric size Inch size 1 8" 3.2 4 6 8 10 12 5 32 " 3 16 " 1 4" 5 16 " 3 8" 1 2" AS1001F 6,10, 16, 20 AS2001F 20, 25, 32 Application to inch size tubing Metric size (Release bushing: White color) 3.2, 4, 6, 8, 10, 12 Inch size (Release bushing: Orange color) 1/8", 5/32", 3/16", 1/4", 5/16", 3/8", 1/2" AS2051F 20, 25, 32, 40 AS3001F 40, 50, 63 AS4001F
HOW TO ORDER AL 30 03 BD 1N A 1 3 4 5 2 1 Symbol Description Body size 10 20 30 40 50 60 Meter thread (M5) Rc N NPT F G Thread type Nil 2 M5 M5 01 1/8 02 1/4 03 3/8 04 1/2 06 3/4 10 1 Port size 3 Nil Without mounting option B With bracket 4 Option(Mounting) Nil Polycarbonate bowl 2 Metal bowl 6 Nyron bowl 8 Metal bowl with sight glass C With bowl guard (steel plate) 6C With bowl guard
Abnormal (19 V or less) Output area mapping For EX260-SEN1/-SEN2 Output data Offset MSB LSB MSB LSB (Word) 15 8 7 0 0 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 1 31 30 29 28 27 26 25 24 23 22 21 20 19 18 17 16 For EX260-SEN3/-SEN4 Output data Offset MSB LSB MSB LSB (Word) 15 8 7 0 0 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 -38No.EX-OMP0013-E Dimensions If a fieldwireable connector is used for the
SMC's Manifold Base Manifold Specification VVEX Series.Features · Using the VVEXB/2/4 Series, a manifold with up to 10 stations is possible.
Output impedance: Approx. 1 k -23 Switch output NPN open collector output 1 output Max. 30 V, 80 mA Failure predictive output NPN open collector output 1 output -24 Switch output NPN open collector output 1 output Max. 30 V, 80 mA Failure predictive output NPN open collector output 1 output Analog output: 1 to 5V (5%F.S.)
Note) Metric size 23 04 06 08 10 12 Inch size 3.2 01 03 05 07 09 11 13 1/8" 5/32" 3/16" 1/4" 5/16" 3/8" 1/2" 4 6 8 10 12 Made to Order (For details, refer to page 622.)
Also, if pipe tape is used, leave 1 thread ridge exposed at the end of the threads. 5 VEX-OMA0002-E VEX1 Series Regulator Valve / Precautions 3 Be sure to read this before handling. Air Supply Maintenance Caution Warning 1. Ensure that the fluid and ambient temperature are within the specified range.
2030 10 1% * -7No.PS-OMG0005CN-E 0 01 28 C2 PSE56 0 (01MPa) (1) C2 1 (0-101kPa) 3 (-100100kPa) *PSE200 4 (0500KPa) (15V) 01 R1/8(M5) 28 (420mA) 02 R1/4(M5) C01 Rc1/8 N01 NPT1/8(M5) N02 NPT1/4(M5) A2 URJ1/4 B2 TSJ1/4 ZS-28-C 1 Rc1/4 ZS-31-X175 1 NPT1/4 ZS-31-X186 1 Rc1/8 ZS-31-X188 1 NPT1/8 ZS-31-X189 1 15[V]F.S.=514[V] (1F.S.40.010.04[V]) F.S. ( 25[]ON-OFF (1K 1M A/D 5V A/D