IN OUT Model Port size D C B A 30 30 23.5 14 M5 x 0.8 SRP111-M5 40 40 22.5 15 Rc 1/8 SRP111-01 C D 3 Series SRP Safety Instructions These safety instructions are intended to prevent a hazardous situation and/or equipment damage.
High Suction Vacuum Work 1 Work 2 Work n Max.A ON point OFF point Min.B Not adsorption Work 1 Work 2 Work n Atmosphere A B 4 A B 4 = A ON point Max.A: Maximum pressure value when workpiece is vacuumed. Min.B: Maximum pressure value when workpiece is not vacuumed.
-04 AS121F-M5-03 5/32" M5 x 0.8 M5 x 0.8 8 17.3 22.2 7 9.3 22.1 9.6 4 25 25.8 22.1 28.6 9.3 17.3 AS121F-U10/32-04 AS121F-U10/32-03 5/32" 10-32UNF 10-32UNF AS121F-M5-06 AS121F-M5-05 3/16" M5 x 0.8 M5 x 0.8 11.4 21.3 26.1 7 16.5 13.5 11.7 22.9 11.6 18.1 6 AS121F-U10/32-06 AS121F-U10/32-05 3/16" 10-32UNF 10-32UNF 8 11.7 28.6 25.8 22.2 25 9.6 AS221F-01-23 AS2 1F-M5-07 20.4 16 9.3 27.5 3.2 1/4
One-touch fitting ARJ310-01 ARJ310-N01 ARJ310F-01-04 ARJ310F-01-06 ARJ310F-N01-03 ARJ310F-N01-07 R 1/8, M5 x 0.8 NPT 1/8, M5 x 0.8 R 1/8, M5 x 0.8 NPT 1/8, M5 x 0.8 Note) M5 x 0.8 female thread is cut inside the pipe.
Required screws are as follows: 2 x M5 (End plate: torque = 1.5 Nm) 2 x M5 (SI Unit : torque = 1.5 Nm) 4 x M (Valve manifold: refer to valve manifold catalogue) Fig. 7-1 Required screws All manifolds are mounted using 8 screws (except VQC4000 which uses 7 screws). 25 No.EX##-OMY0004 7.1.1. Valve manifold connection Connect the valve manifold with the 2 screws on the SI Unit.
torque Nm (mm) MHF28D M3 x 0.5 0.63 4 MHF2-12D M4 x 0.7 1.5 5 MHF2-16D M5 x 0.8 3 5.5 MHF2-20D M6 x 1 5.2 6 Screw-in depth Model Bolt Max. tightening torque Nm (mm) MHF28D M2.5 x 0.45 0.36 4 MHF2-12D M3 x 0.5 0.63 5.2 MHF2-16D M4 x 0.7 1.5 MHF2-20D M5 x 0.8 3 When MHF2-8D* and MHF2-12D* are mounted body through-hole, use the attached special bolts.
For IITV00-n Total weight (g) Stations (n) x 100 + 130 (Weight of end block A, B assembly) + Weight (g) of DIN rail Note 2) Specifications other than the following are optional.
The scale indication range is also printed on the to JIS B 4609-2008 Table 1. product.
Replacement method Standard replacement period Refrigerating compressor 1 B 20,000 hours (6 years) Plate type heat exchanger 1 B 20,000 hours (6 years) Water regulating valve 1 B 20,000 hours (6 years) High pressure switch 1 B 20,000 hours (6 years) Low pressure switch 1 A 20,000 hours (6 years) Magnetic contactor 1 A 20,000 hours (6 years) Programmable controllers 1 A 20,000 hours (6 years
Model MQR1-M5 MQR2-M5 MQR4-M5 MQR8-M5 MQR12-M5 Number of circuits 1 2 4 8 12 Operating fluid Air / Inert gas Seal structure Metal seal Guide structure Bearing supported Bearing supported at both ends Port size Male R1/8 Female M5 x 0.8 M5 x 0.8 Flow rate C[dm3/(s.bar)] b Cv characteristics 0.50 0.40 0.17 Lubrication Not required Min. operating pressure -100kPa Max. operating pressure 1.0MPa
5) Y V IDF100F V IDF125F V IDF150F B 1.3 IDF100150F-W 1 4 IDX-OM-Z004 1 3.6 5.2 (IDF100F, 125F) R OFF 5.2 L1 L2 L3 M5 9.5mm 3.5mm 2 1,2 3,4 5,6 L1,L2,L3 PE: L1 L2 L3 PE 1 2 3 4 5 6 M4 9.5mm 5.5mm M3 6.5mm 1.25mm 2 2 1.3 IDF100150F-W 1 5 IDX-OM-Z004 1 3.6 5.2 5.2 (IDF150F) R OFF L1 L2 L3 M5 9.5mm 3.5mm 2 1,2 3,4 5,6 L1,L2,L3 PE: L1 L2 L3 PE 1 2 3 4 5 6
AS-FE 1/8 0.07 1/4 0.16 KE 3/8 0.2 1/2 0.4 AS-FG When performing the piping work, turn the tightening tool in the horizontal direction to the hexagon across flats of the body B so that any moment is not applied to the body A. If the tool is in contact with the body A, this may cause the body B to come off. AS-FP AS-FM 4.
(Value in the initial stage) Model Flow characteristics (2) Type of actuation Port size Pilot port size b Cv b Cv Valve model Pilot C C Body ported Body ported Base mounted VZA212-P-M5 0.13 0.35 0.52 0.15 0.43 0.60 N.C. M5 x 0.8 M5 x 0.8 Body side VZA222-P-M5 0.13 0.35 0.52 0.15 0.43 0.60 N.O. M5 x 0.8 M5 x 0.8 Body side VZA214-1P-01 0.22 0.35 0.85 0.25 0.30 1.0 N.C.
(mm) Connection thread R Effective area (mm2) Min. port size <M5, M6> <M5, M6> Weight (g) M D1 D2 L1 L2 A Model Nylon Urethane M5 x 0.8 M6 x 1 KSL04-M5 KSL04-M6 KSL04-01S KSL06-M5 KSL06-M6 KSL06-01S KSL06-02S KSL08-01S KSL08-02S KSL08-03S KSL10-02S KSL10-03S KSL10-04S KSL12-03S KSL12-04S 20.5 21 22 8 9 4 12 10.4 21 16 2.5 3.5 3.5 23.5 23.5 1 8 M5 x 0.8 M6 x 1 12 14 22 21 21.5 23 2.5 3 3.5
AS121FG-M5-23 AS121FG-U10/32-01 9.6 25.8 28.6 12.3 8 7 12.7 17.3 22.1 8.4 8.4 3.2 M5 0.8 25 1/8" 22.2 12.3 17.3 22.1 12.7 AS221FG-01-23 AS121FG-U10/32-03 14.2 31.1 36.1 14.3 12 16 12.7 20.4 27.5 9.3 9.3 3.2 32.1 5/32" 27.1 R 1/8 8 10-32 UNF 28.6 25.8 25 22.2 7 9.6 AS121FG-M5-04 AS121FG-U10/32-05 21.3 26.1 12.3 12.7 17.3 22.1 9.3 11.4 4 3/16" 16.5 M5 0.8 11.7 9.6 25.8 28.6 8 7 25 22.2 AS121FG-M5
Model Av x 106 m2 C [dm3/(sbar)] N.C. 0.96 Cv 0.40 b 0.14 Cv converted 0.04 1 0.04 VDW10 M5 1.6 0.07 0.07 1.7 0.25 0.30 1.6 0.09 0.08 1.9 0.45 0.31 M5 1/8 (6A) VDW20 2.3 0.18 0.18 4.3 0.45 0.58 3.2 0.33 0.30 7.2 0.38 1.2 2 0.16 0.16 3.8 0.52 0.52 1/8 (6A) 1/4 (8A) VDW30 3 0.30 0.28 6.7 0.52 1.0 4 0.46 0.44 11 0.49 1.5 244
Front view Mounting holes on the top Mounting holes Theread size Name Type Mounting hole Main body M5 Side Support A Mounting hole M5 Side Support B Mounting Tap M6 x1 Side support A Side support B MY-S25A MY-S25B Mounting holes Mounting taps Installation of work Use 4 threaded holes on the top of slider for installation of work.
Auto Switches/Proper Mounting Position at Stroke End Detection B A (mm) D-A9, D-A9V (mm) D-M9, D-M9V (mm) D-F9W, D-F9WV A A A B B B Operating range Operating range Operating range Nominal size 16 25 Nominal size 16 25 Nominal size 16 25 3 44 116 48 112 48 112 8 8.5 3.5 54 156 58 152 58 152 Auto Switch Mounting When mounting the auto switches, they should be inserted into the actuators switch
LVP6 Pilot port thread (fitting) type Material Symbol Nil 1 2 N Thread (fitting) type 6 mm one-touch fitting Rc1/8 M5 x 0.8 NPT1/8 Symbol FKM EPDM O-ring material Nil N Flow sensor Option Drain valve Applicable valve type Symbol Symbol Option N.C. N.O. Double acting Process pump PA PB PA Nil None With flow rate adjustment 1 B A B A B A Air Operated Valve LVP PB N.C. N.O.
Port size Body size 2 to 16 1 to 4 M5 to 1/2 1/8" to 1/2" Metric size Inch size 3.2 to 12 1 to 4 M5 to 1/2 1/8" to 1/2" Refer to the Web Catalog for details.