(Normally Open) at non-pressurized with drain emissions, Pressure Gauge: No (No Pressure Port Plug), Size of Body: 30, Check Valve: None, Pressure Switch: None, Residual Pressure Relief 3-Port Connection Valve: None, Set Pressure: 0.05 to 0.7 MPa, Drain Outlet: N/A, Lubricator Oil Discharge Outlet: Without drain cock, Pressure Unit: Name plate and pressure gauge unit: MPa, T shape spacer:
Body Size: 30, Thread: G, Port Size: 1/4, Option: Standard, Attachment: Standard, Semi-Standard 1: Standard, Semi-Standard 2: Standard
Body Size: 30, Thread: G, Port Size: 3/8, Option: Standard, Attachment: Standard, Semi-Standard 1: Standard, Semi-Standard 2: Standard
Body Size: 30, Thread: F (G), Port Size: 03 (3/8), Option: Standard, Attachment: Standard, Semi-Standard 1: Standard, Semi-Standard 2: Standard
Body Size: 30, Thread: Rc (Rc: for Sizes 20, 25, 30, 40; M5: for Size 10), Port Size: 02 (1/4), Option: G (Size 20 25, 30, 40: Round Type Pressure Gauge w/Limit Indicator; Size 10: Round Type Pressure Gauge w/o Limit Indicator), Attachment: Standard, Semi-Standard 1: Standard, Semi-Standard 2: Standard
Body Size: 30, Thread: Rc (Rc: for Sizes 20, 25, 30, 40; M5: for Size 10), Port Size: 03 (3/8), Option: G (Size 20 25, 30, 40: Round Type Pressure Gauge w/Limit Indicator; Size 10: Round Type Pressure Gauge w/o Limit Indicator), Attachment: Standard, Semi-Standard 1: Standard, Semi-Standard 2: Standard
Body Size: 30, Thread: F (G), Port Size: 02 (1/4), Option: Standard, Attachment: Standard, Semi-Standard 1: Standard, Semi-Standard 2: Standard
Body Size: 30, Thread: Rc (Rc: for Sizes 20, 25, 30, 40; M5: for Size 10), Port Size: 03 (3/8), Option: CM (C + M), Attachment: Standard, Semi-Standard 1: Standard, Semi-Standard 2: Standard
Body Size: 30, Thread: Rc (Rc: for Sizes 20, 25, 30, 40; M5: for Size 10), Port Size: 03 (3/8), Option: DG (D + G), Attachment: Standard, Semi-Standard 1: Standard, Semi-Standard 2: Standard
Body Size: 30, Thread: F (G), Port Size: 03 (3/8), Option: C (N.C. Float Type Auto Drain), Attachment: Standard, Semi-Standard 1: Standard, Semi-Standard 2: Standard
Body Size: 30, Thread: F (G), Port Size: 03 (3/8), Option: D (N.O. Float Type Auto Drain), Attachment: Standard, Semi-Standard 1: Standard, Semi-Standard 2: Standard
Body Size: 30, Thread: F (G), Port Size: 03 (3/8), Option: CG (C + G), Attachment: Standard, Semi-Standard 1: Standard, Semi-Standard 2: Standard
Body Size: 30, Thread: Rc (Rc: for Sizes 20, 25, 30, 40; M5: for Size 10), Port Size: 03 (3/8), Option: C (N.C. Float Type Auto Drain), Attachment: Standard, Semi-Standard 1: Standard, Semi-Standard 2: Standard
Body Size: 30, Thread: Rc (Rc: for Sizes 20, 25, 30, 40; M5: for Size 10), Port Size: 02 (1/4), Option: DG (D + G), Attachment: Standard, Semi-Standard 1: Standard, Semi-Standard 2: Standard
Body Size: 30, Thread: Rc (Rc: for Sizes 20, 25, 30, 40; M5: for Size 10), Port Size: 03 (3/8), Option: Standard, Attachment: Standard, Semi-Standard 1: Standard, Semi-Standard 2: Standard
Vertical Operation 1 2 P2 W A P1 a (b) (a) P0 P0 a A W (1) The speed is controlled with meter-out control. When the meterin controller is used in conjunction with the meter-out controller, lurching is reduced. () (2) Depending on the size pf the load, installing a regulator with check valve at position (a) can decrease lurching during descent, and operation delay during ascent.
Vertical Operation 1 2 P2 W A P1 a (b) (a) P0 P0 a A W (1) The speed is controlled with meter-out control. When the meterin controller is used in conjunction with the meter-out controller, lurching is reduced. () (2) Depending on the size pf the load, installing a regulator with check valve at position (a) can decrease lurching during descent, and operation delay during ascent.
: (800) 258-9200-www.stevenengineering.com 1 (P) 5 (R1) 3 (R2) (A) 4 (B) 2 Sub-plate port size Thread type Rc Nil Without sub-plate Side ported Rc 1/4 Nil A02 A03 B02 B03 YZ NPTF T G F Side ported Rc 3/8 Bottom ported Rc 1/4 1 (P) 5 (R1) 3 (R2) Bottom ported Rc 3/8 (A) 4 (B) 2 Port R is Rc 3/8 Seal FHG Nil R Metal seal Rubber seal 1 (P) 5 (R1) 3 (R2) (A) 4 (B) 2 Option FJG Nil Z V None
With functions narrowed down, 2 independent temperature control systems have been achieved with only a single compressor , a single pump , and a single tank .
PA=0.5 MPa A=0.5 MPa 6 x 6 pcs. T2 (Response time) Energization time T (ms) VXF2160/VXFA2160 T1 (Idle time) Air tank 41l PA=0.7 MPa A=0.7 MPa Air tank 41l PA=0.7 MPa A=0.7 MPa Air tank 70l PA=0.7 MPa A=0.7 MPa Air tank 41l PA=0.7 MPa Air tank 41l PA=0.7 MPa 6 x 10 pcs. Air tank 70l PA=0.7 MPa Tube length L (mm) 6 x 10 pcs.