SMC Corporation of America
Elite Part Number Search
Search Results "NCDA1B250-0100 0200-A54Z-XC10"

Magnet: Built-in, Mounting: Basic, Bore Size: 2 1/2", Stroke A: 12", Cushion A: None, Rod Boot A: None, Stroke B: 16", Cushion B: None, Rod Boot B: None, Auto Switch: A54--Reed, DC Volt >5<24, AC Volt <200, LED, Lead Wire or Prewired Connector: 0.5m (Or None in the Case of No Switch), Number: 2 pcs. (Or None in the Case of No Switch), Dual, Tandem Option: Dual Op., Dbl. Rod

Magnet: Built-in, Mounting: Basic, Bore Size: 2 1/2", Stroke A: 12", Cushion A: None, Rod Boot A: None, Stroke B: 16", Cushion B: None, Rod Boot B: None, Auto Switch: A54--Reed, DC Volt >5<24, AC Volt <200, LED, Lead Wire or Prewired Connector: 3m Lead Wire, Number: 2 pcs. (Or None in the Case of No Switch), Dual, Tandem Option: Dual Op., Dbl. Rod

Magnet: Built-in, Mounting: Basic, Bore Size: 2 1/2", Stroke A: 12", Cushion A: Rod End, Rod Boot A: Neoprene, Stroke B: 12", Cushion B: Rod End, Rod Boot B: Neoprene, Auto Switch: A53--Reed, DC Volt >5<24, LED, Lead Wire or Prewired Connector: 3m Lead Wire, Number: 2 pcs. (Or None in the Case of No Switch), Dual, Tandem Option: Dual Op., Dbl. Rod

Magnet: Built-in, Mounting: Basic, Bore Size: 2 1/2", Stroke A: 18", Cushion A: Both Ends, Rod Boot A: None, Stroke B: 10", Cushion B: Both Ends, Rod Boot B: None, Auto Switch: A53--Reed, DC Volt >5<24, LED, Lead Wire or Prewired Connector: 3m Lead Wire, Number: 2 pcs. (Or None in the Case of No Switch), Dual, Tandem Option: Dual Op., Dbl. Rod

Magnet: Built-in, Mounting: Basic, Bore Size: 2 1/2", Stroke A: 10", Cushion A: None, Rod Boot A: None, Stroke B: 10", Cushion B: None, Rod Boot B: None, Auto Switch: M9B--Solid State, Gen. Purpose, 2 Wire, Horizontal, Lead Wire or Prewired Connector: 3m Lead Wire, Number: 2 pcs. (Or None in the Case of No Switch), Dual, Tandem Option: Dual Op., Dbl. Rod

Magnet: Built-in, Mounting: Basic, Bore Size: 2 1/2", Stroke A: 12", Cushion A: Both Ends, Rod Boot A: None, Stroke B: 4", Cushion B: Both Ends, Rod Boot B: None, Auto Switch: M9P--Solid State, Gen. Purpose, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: 3m Lead Wire, Number: 4 pcs., Dual, Tandem Option: Dual Op., Dbl. Rod

Magnet: Built-in, Mounting: Basic, Bore Size: 2 1/2", Stroke A: 1 1/2", Cushion A: Both Ends, Rod Boot A: None, Stroke B: 8", Cushion B: Both Ends, Rod Boot B: None, Auto Switch: A54--Reed, DC Volt >5<24, AC Volt <200, LED, Lead Wire or Prewired Connector: 3m Lead Wire, Number: 4 pcs., Dual, Tandem Option: Dual Op., Dbl. Rod

Magnet: Built-in, Mounting: Basic, Bore Size: 2 1/2", Stroke A: 12", Cushion A: Both Ends, Rod Boot A: None, Stroke B: 2 1/2", Cushion B: Both Ends, Rod Boot B: None, Auto Switch: J59--Solid State, Gen. Purpose, 2 Wire, Lead Wire or Prewired Connector: 3m Lead Wire, Number: 4 pcs., Dual, Tandem Option: Dual Op., Dbl. Rod

Magnet: Built-in, Mounting: Basic, Bore Size: 2 1/2", Stroke A: 3", Cushion A: None, Rod Boot A: None, Stroke B: 1", Cushion B: None, Rod Boot B: None, Auto Switch: M9B--Solid State, Gen. Purpose, 2 Wire, Horizontal, Lead Wire or Prewired Connector: 3m Lead Wire, Number: 2 pcs. (Or None in the Case of No Switch), Dual, Tandem Option: Dual Op., Dbl. Rod

Magnet: Built-in, Mounting: Basic, Bore Size: 2 1/2", Stroke A: 4", Cushion A: Both Ends, Rod Boot A: None, Stroke B: 4", Cushion B: Both Ends, Rod Boot B: None, Auto Switch: M9P--Solid State, Gen. Purpose, 3 Wire PNP, Horizontal, Lead Wire or Prewired Connector: 0.5m Cord Length, M12-4 Pin Connector, Number: 2 pcs. (Or None in the Case of No Switch), Dual, Tandem Option: Dual Op., Dbl. Rod

This is a legacy product. Please contact us for the latest version.sales@ocaire.com

This is a legacy product. Please contact us for the latest version.sales@ocaire.com

This is a legacy product. Please contact us for the latest version.sales@ocaire.com

Example 1) ASCII mode Received function code: 04(0 0100)ASCII code 30h34h Abnormal function code: 84(1000 0100)ASCII code 38h34h Example 2) RTU mode Received function code:04 (0 0100) Abnormal function code:84 (1000 0100) 2) Error Code Assign error code below. 01: Function code of a command is outside the standard. 02: The specified address of register is outside the range. 03: Data field

Example 1) ASCII mode Received function code: 04(0 0100) ASCII code 30h, 34h Abnormal function code: 841000 0100 ASCII code 38h, 34h Example 2) RTU mode Receive function code: "04" (0 0100) Abnormal function code: "84" (1000 0100 2) Error Code Assign error code below. 01 : Function code of a command is outside the standard 02 : The specified address of register is outside the range. 03 :

Example 1) ASCII mode Received function code: 04(0 0100) ASCII code 30h, 34h Abnormal function code: 841000 0100 ASCII code 38h, 34h Example 2) RTU mode Receive function code: "04" (0 0100) Abnormal function code: "84" (1000 0100 2) Error Code Assign error code below. 01 : Function code of a command is outside the standard 02 : The specified address of register is outside the range. 03 :

This is a legacy product. Please contact us for the latest version.sales@ocaire.com

Series NCA1 medium duty tie rod cylinders are NFPA interchangeable, have a crimped piston rod assembly, are pre-lubricated and available in 11 mounting styles. Bore sizes range from 1.5 to 4 inches. The NCA1 expanded line of medium duty cylinders offer bore sizes ranging from 5 to 8 inches, and come standard with adjustable air cushion.5in. bore medium duty air cylinder, 11 NFPA mounting

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, BASE CYLINDER, ACTUATOR, NCA1 TIE-ROD CYLINDER, PC, 2.5 INCH NCA1 OTHERS (COMBO), .00000 lb

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, BASE CYLINDER, ACTUATOR, NCA1 TIE-ROD CYLINDER, PE, 2.5 INCH NCA1 DBL-ACT AUTO-SW, .00000 lb