Cylinder (Tube) Inner Diameter(φ): 100, Stroke(mm): 100, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.03 to 1.0, Specification: Built-in magnet
Cylinder (Tube) Inner Diameter(φ): 100, Stroke(mm): 100, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, End Locking: No, Valves: No, Operating Pressure(MPa): 0.03 to 1.0, Specification: Built-in magnet
Output(V): -, Power Supply Type: DC, Power Supply Voltage(V): [24] 24±10%, Protection Structure: IP40, Unit Specifications: With unit conversion function, Bracket: None, Lead Wire: With lead wire with connector (2 m), Flow rate control valve: None, Piping Specification: Straight, Custom-made Specifications: None, Rated Pressure Range: -70 kPa to 750 kPa, Rating Flow Range(L/min): 2 to 100
Output(V): -, Power Supply Type: DC, Power Supply Voltage(V): [24] 24±10%, Protection Structure: IP40, Unit Specifications: SI unit fixed, Bracket: None, Lead Wire: With lead wire with connector (2 m), Flow rate control valve: None, Piping Specification: Straight, Custom-made Specifications: None, Rated Pressure Range: -70 kPa to 750 kPa, Rating Flow Range(L/min): 2 to 100 (50), Option:
Flow Range(L/min): 2 to 100 (50), Option: None, Applicable Tube Size: -, Instruction Manual: With operation manual (Japanese and English), Calibration Certificate: Without calibration certificate, External input: None, Contact Configuration: 1ab
Voltage Output(V): -, Power Supply Type: DC, Power Supply Voltage(V): [24] 24±10%, Protection Structure: IP40, Unit Specifications: SI unit fixed, Bracket: None, Lead Wire: With lead wire with connector (2 m), Flow rate control valve: None, Piping Specification: Straight, Custom-made Specifications: None, Rated Pressure Range: -70 kPa to 750 kPa, Rating Flow Range(L/min): 2 to 100 (50),
2 to 100 (50), Option: None, Applicable Tube Size: ø8, Instruction Manual: With operation manual (Japanese and English), Calibration Certificate: Without calibration certificate, External input: None, Contact Configuration: 1ab
Voltage Output(V): -, Power Supply Type: DC, Power Supply Voltage(V): [24] 24±10%, Protection Structure: IP40, Unit Specifications: SI unit fixed, Bracket: None, Lead Wire: With lead wire with connector (2 m), Flow rate control valve: Yes, Piping Specification: Straight, Custom-made Specifications: None, Rated Pressure Range: -70 kPa to 750 kPa, Rating Flow Range(L/min): 2 to 100 (50), Option
Voltage Output(V): -, Power Supply Type: DC, Power Supply Voltage(V): [24] 24±10%, Protection Structure: IP40, Unit Specifications: SI unit fixed, Bracket: None, Lead Wire: With lead wire with connector (2 m), Flow rate control valve: Yes, Piping Specification: Straight, Custom-made Specifications: None, Rated Pressure Range: -70 kPa to 750 kPa, Rating Flow Range(L/min): 2 to 100 (50), Option
Cylinder (Tube) Inner Diameter(φ): 100, Stroke(mm): 100, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.05~1, Cushion: None, Specification: Without built-in magnet, Support
Cylinder (Tube) Inner Diameter(φ): 100, Stroke(mm): 100, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.05~1, Cushion: None, Specification: Without built-in magnet, Support
Cylinder (Tube) Inner Diameter(φ): 100, Stroke(mm): 100, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.05~1, Cushion: None, Specification: Without built-in magnet, Support
Cylinder (Tube) Inner Diameter(φ): 100, Stroke(mm): 100, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.05~1, Cushion: None, Specification: Without built-in magnet, Support
Cylinder (Tube) Inner Diameter(φ): 100, Stroke(mm): 100, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.05~1, Cushion: None, Specification: Without built-in magnet, Support
Cylinder (Tube) Inner Diameter(φ): 100, Stroke(mm): 100, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.05~1, Cushion: None, Specification: Without built-in magnet, Support
Cylinder (Tube) Inner Diameter(φ): 100, Stroke(mm): 100, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.05~1, Cushion: None, Specification: Without built-in magnet, Support
Cylinder (Tube) Inner Diameter(φ): 100, Stroke(mm): 100, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.05~1, Cushion: None, Specification: Without built-in magnet, Support
Cylinder (Tube) Inner Diameter(φ): 100, Stroke(mm): 100, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.05~1, Cushion: None, Specification: Without built-in magnet, Support
Cylinder (Tube) Inner Diameter(φ): 100, Stroke(mm): 100, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.05~1, Cushion: None, Specification: Without built-in magnet, Support
Cylinder (Tube) Inner Diameter(φ): 100, Stroke(mm): 100, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: [Block Shape] Block shape, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -10~70, Operating Pressure(MPa): 0.05~1, Cushion: None, Specification: Without built-in magnet, Support