Auto Switch Proper Mounting Position (Detection at Stroke End) Electrical entry direction: Inward Electrical entry direction: Outward D B A C B D-Z7Z8, D-Y7W D-Y5, D-Y7 D-Y6, D-Y7V D-Y7WV D-Y7BA Bore size (mm) A C 16.5 (15) 23.5 (22) 34 (32.5) 46 (44.5) 46 (44.5) 56 (54.5) D 0.5 (1) 3.5 (2) 0.5 (1) 3 (1.5) 5 (3.5) 5 (3.5) C 18 25 35.5 48 48 58 D 2 5 2 4.5 6.5 6.5 C 10.5 17.5 28 40 40 50 D
[dm3/ (sbar)] b Cv C [dm3/ (sbar)] b Cv C [dm3/ (sbar)] b Cv C [dm3/ (sbar)] b Cv Grommet 0.44 0.40 0.40 0.44 0.40 0.41 0.63 0.63 0.41 0.63 0.13 0.10 0.10 0.13 0.10 0.20 0.14 0.14 0.20 0.14 VK332 0.47 0.41 0.41 0.47 0.41 0.85 0.65 0.65 0.85 0.65 0.47 0.38 0.38 0.47 0.38 0.76 0.41 0.41 0.76 0.41 0.44 0.27 0.27 0.44 0.27 0.26 0.24 0.24 0.26 0.24 0.13 0.10 0.10 0.13 0.10 0.19 0.15 0.15 0.19
H1 AL 4-ND through 4-ET B A NB NA K 2 x 4-NC counter bore Prepared hole diameter NE H S + Stroke ZZ + Stroke BY BB BS + Stroke BA 2-BT (mm) Stroke range Model BY C D GW GY H H1 B AL BA BB BP BS BT ET EY GA GA1 GB GC GC1 A B1 22 26 30 35 19.5 23.5 27 32 24 28 32 39 8 6.5 9 12 9 6.5 8 10 17 19 22 27 MLUB25 MLUB32 MLUB40 MLUB50 M5 x 0.8 73 87 87 102.5 M5 x 0.8 depth 7.5 M6 x 1 depth 12 7 8 9
NG G TT UU A N 2 x 2-P (Hexagon socket head taper plug) Z + Stroke (mm) Model MY3B16 MY3B25 MY3B40 MY3B63 A B C E G H HG JJ KK L LD LL LW M MM N 41 28.5 3.5 65 5.0 5.0 27 9.5 M4 x 0.7 2 6 18 61 6.0 M4 x 0.7 13.5 61 41.5 5.5 95 7.5 7.4 37 14.0 M5 x 0.8 2 8 25 89 9.5 M5 x 0.8 20.0 90 58.0 8.6 160 12.0 12.0 54 18.0 M6 x 1 2 12 38 138 14.0 M6 x 1 27.0 134 68.0 11.0 220 22.0 16.5 84 20.5 M8 x
m GH641 m3 m5 m 200 kPa ISA3-F ISA3-G 1 m3 m5 m 1 m3 m5 m [mm] [mm] 9 0 10010 ISA3-H 1 m3 m5 m [mm] 29 0 30030 -20No.PS-OMT0001CN-E 2 ISA3-() ISO1179-1 1 2 3 4 5 6 L1 38 76 114 152 190 228 C(4 ) C(6 ) F(G ) H 13 13.6 19 ISA-14() -21No.PS-OMT0001CN-E 2 ISA3-(DIN ) ISO1179-1 1 2 3 4 5 6 L1 38 76 114 152 190 228 L2 62.5 125 162.5 200 237.5 275 L3 73 135.5 173 210.5 248 285.5
How to Order Standard B 20 30 D C CQSY B 20 30 D C F9BW S CDQSY With auto switch Number of auto switches With auto switch (Built-in magnet) 2 pcs. 1 pc. n pcs.
C D 15 (mm) Auto switch model A D-F9 B C D D-A9 D-F9 D-A9 D-F9 D-A9 D-F9 Bore size (mm) 17.5 15 D-A9 21.5 76.5 72.5 56.5 60.5 Note) Auto switches cannot be installed in Area C in the case of 15. 25, 32 (mm) A D-Y5 D-Y7 D-Y7W B C D Auto switch model D-Y5 D-Y7 D-Y7W D-Y5 D-Y7 D-Y7W D-Y5 D-Y7 D-Y7W D-Z7 D-Z8 D-Z7 D-Z8 D-Z7 D-Z8 D-Z7 D-Z8 Bore size (mm) 25 22 101 103 47 47 78 78 22 32 30.5
H1 AL 4-ND through 4-ET B A NB NA K 2 x 4-NC counterbore Prepared hole diameter NE H S + Stroke ZZ + Stroke BY BB BS + Stroke BA 2-BT (mm) Stroke range Model A BY D GW GY H H1 B1 C B AL BA BB BP BS BT ET GA GA1 GB GC GC1 EY 22 26 30 35 19.5 23.5 27 32 24 28 32 39 8 6.5 9 12 9 6.5 8 10 17 19 22 27 MLUB25 MLUB32 MLUB40 MLUB50 M5 x 0.8 73 87 87 102.5 M5 x 0.8 depth 7.5 M6 x 1 depth 12 7 8 9
Tap M5 thread on the brackets mounting positions at the installation side, and fix the ionizer body and brackets with M5 threads. M5 tap M5 threads 4. Adjust angle of the ionizer body to ensure proper static charge elimination, and fix it with detent threads (M5) of brackets.
x 0.8 M5 x 0.8 M3 x 0.8 Note) Only for external pilot Flow Characteristics Flow characteristics Port size 1R2 (PRA) 2R3 (ARR) Manifold C [dm3/(sbar)] 1(P), 3(R) port 2(A) port b Cv C [dm3/(sbar)] b Cv Type SS3YJ7-20 1/8 2.2 2.2 2.1 2.2 2.0 1.6 2.1 0.34 0.39 0.35 0.35 0.27 0.32 0.24 0.55 0.59 0.59 0.59 0.47 0.39 0.51 2.3 2.4 2.3 2.4 2.2 2.2 2.3 0.27 0.32 0.27 0.36 0.32 0.27 0.31 1/8 1/4 1
Mass: 0.8 [kg] (1.76 [lb]) Mounting screw Screw size: M5 Tightening torque: 3.24 [N m] (28.7 [lb in]) Terminal signal layout For 3-phase or 1-phase 200 to 230VAC For 1-phase 100 to 120VAC PE terminal Approx. 40 L1 L1 6 L2 L2 L3 CNP1 CNP1 Screw size: M4 Tightening torque: N N 2-M5 screw 1.2 [N m] (10.6 [lb in]) P1 P1 P2 P2 P P C C CNP2 CNP2 D D L11 L11 L21 L21 U U CNP3 CNP3 V V W W Mounting
) 38L A B(ZS-46-A2) 38L B -15No.PS-OMU0005CN-C (a)(a) (b) (ZS-46-B) +(ZS-46-D) 90 -16No.PS-OMU0005CN-C (-M5) 1/6~1/4 1~1.5Nm (ZS-46-N) -01-N01 23 3~5 Nm -C4L-C6L 1/61/4 1~1.5Nm -17No.PS-OMU0005CN-C -18No.PS-OMU0005CN-C () TU0425( 42.5) -19No.PS-OMU0005CN-C FG -20No.PS-OMU0005CN-C Z/ISE20B(F)-S/-R () NPN 2 Max.28 V80 mA 1 V R15 V 1 k S420 mA 12 V 300 24 V 600 50 -S/-R () NPN 2 Max
Approx. 300 Q F D D Approx. 300 Q F G1/2 Width across flats H Width across flats H C E C E R R B A 2 x P Port size 2 x P Port size B A M M 2 x J thread depth K 2 x J thread depth K DIN terminal: D Conduit terminal: T S Q F 34 D Cable 6 to 12 (Q) F G1/2 D 25 Width across flats H Width across flats H T C M C R R E E (S) A 2 x P Port size A 2 x P Port size B B M 2 x J thread depth K G1/2 2 x
-40 M8 x 1.25 17.7 16 Max. tightening torque (Nm) Model Screw MHZ2-10 M2.5x0.45 0.49 MHZ2-16 M3 x 0.5 0.88 MHZ2-20 M4x0.7 2.1 MHZ2-25 M5 x 0.8 4.3 MHZ2-32 M5 x 0.8 4.3 MHZ2-40 M6x1 7.3 Note) If auto switches D-Y59, D-Y69, or D-Y7P are used, or the auto switch is mounted to the corner of the body, only a tapped body can be used.
H1 AL 4-ND through 4-ET B A NB NA K 2 x 4-NC counter bore Prepared hole diameter NE S + Stroke H ZZ + Stroke BY BB BS + Stroke BA 2-BT (mm) Stroke range Model BY C D GW GY H H1 B AL BA BB BP BS BT ET GA GA1 GB GC GC1 EY A B1 22 26 30 35 19.5 23.5 27 32 24 28 32 39 8 6.5 9 12 9 6.5 8 10 17 19 22 27 M5 x 0.8 73 87 87 102.5 M5 x 0.8 depth 7.5 M6 x 1 depth 12 7 8 9 9 12 14 16 20 M5 x 0.8 depth
Note 3) Bowl assembly for AL30 to AL60 comes with a bowl guard (steel band material). 52 AL10 to 60 Dimensions AL10 AL20 L D Bracket (option) G F Port size K M A Port size C B R C J H OUT OUT IN OUT OUT IN B R P Min. clearance for maintenance Min. clearance for maintenance A AL50, 60 AL30, 40 L D D L Port size Bracket (option) Bracket (option) G F G F Port size M K M K E J C B R C B R H
(Value in the initial stage) Flow Characteristics/Weight Flow characteristics 1 2 (P A) 2 3 (A R) 3 2 (R A) 2 1 (A P) (1) Port size Weight (kg) Series Model C [dm 3/(sbar)] C [dm 3/(sbar)] C [dm 3/(sbar)] C [dm 3/(sbar)] b Cv b Cv b Cv b Cv VPA342 (Body ported) 3.3 4.0 0.83 0.92 0.83/0.83 0.86/0.88 1.7 2.2 1.9/1.8 2.1/2.0 3.1 3.7 3.2/3.2 3.6/3.7 0.93 1.1 0.89/0.89 1.0/0.95 2.0 2.5
Specifications Model PSE530-M5 PSE531-M5 101 to 101kPa PSE532-M5 PSE533-M5 Rated pressure range 0 to 1MPa 0 to 101kPa 0 to 101kPa Proof pressure 1.5MPa 500kPa Air, Non-corrosive gas Fluid 12 to 24VDC (Ripple 10% or less) Power supply voltage Current consumption 15mA or less Output specification Analog output (1 to 5V, Output impedance: Approx. 1k) Accuracy 2% F.S. or less (within rated pressure
Manifold Specifications for 41 and 42 Type Manifold Specifications for 41 and 42 Type SS5Y5-41 SS5Y5-42 SS5Y7-42 Port size Flow characteristics Model 52-SY740 52-SY540 1 4/2 (P A/B) 4/2 5/3 (A/B EA/EB) 1,5,3 Model Applicable valve 4,2 (A,B) (P ,EA,EB) b Cv c[dm3/(sbar)] c[dm3/(sbar)] Single base / B mounting Manifold style b Cv SS5Y5-41 1 (SUP) / 3/5 (EXH) Common SUP / Common EXH 1/4