SMC Corporation of America
Elite Part Number Search
Search Results "CS2F160-1400"

Series: NCA1, Mounting: U (MT1, Rod Trunnion), Bore Size: 150 (1 1/2"), Stroke: 1400 (14"), Option: Both Ends (Air Cushion), X Option: XB6 [Heat Resistant Cylinder, up to 300°F (150°C)]

Series: NCA1, Mounting: F (MF1, Front Flange), Bore Size: 250 (2 1/2"), Stroke: 1400 (14"), Option: Both Ends (Air Cushion), X Option: XB6 [Heat Resistant Cylinder, up to 300°F (150°C)]

Series: NCA1, Mounting: B (MX0, Basic), Bore Size: 200 (2"), Stroke: 1400 (14"), Option: Both Ends (Air Cushion), X Option: XB6 [Heat Resistant Cylinder, up to 300°F (150°C)]

0.5 0.6 Outlet pressure (MPa) Outlet pressure (MPa) 0.4 0.4 0.3 0.3 0.2 0.2 0.1 0.1 0 300 400 500 600 700 0 300 400 500 600 700 0 100 200 0 100 200 Flow rate (l/min (ANR)) Flow rate (l/min (ANR)) ARBY7000 A1 port regulated (PA), B1 port regulated (PB) P port regulated (PA, B) Outlet pressure (MPa) Outlet pressure (MPa) 0.6 0.6 0.5 0.5 0.4 0.4 0.3 0.3 0.2 0.2 0.1 0.1 0 0 0 200 400 600 800 1400

Air slide table w/built-in guide rail, Bore size *: 6, 8, 12, 16, 20, 25, Standard or symetric styles, Adjuster options: rubber stopper, shock absorber, metal stopper, Auto switch capable, Cylinder, Slide Table, GUIDED CYLINDER, D81, 1400 lb

Process valve series VNB, Air operated type, Orifice size: 7mm to 50mm, Port size: 1/8 to 2 Rc(PT), Seal material: NBR, FPM, EPR, Process valve, 2 PORT PROCESS VALVE, J11, 1400 lb

Process valve series VND, Air operated type, Orifice size: 7mm to 50mm, Port size: 1/8 to 2 Rc(PT), Stainless steel available, Process valve, 2 PORT PROCESS VALVE, J19, 1400 lb

Auto switches are available.Low profile , Both single shaft and double shaft are available in all sizes , 2 auto switches are mountable on the same side , Rotating angle adjusting range: 350° to 370° , Options include magnet, shaft type, port thread style, and air cushion, Compact Rotary Actuator, ROTARY ACTUATOR, 525, 1400 lb

Auto switches are available.Low profile , Both single shaft and double shaft are available in all sizes , 2 auto switches are mountable on the same side , Rotating angle adjusting range: 350° to 370° , Options include magnet, shaft type, port thread style, and air cushion, Compact Rotary Actuator, ROTARY ACTUATOR, 525, 1400 lb

Three different finger variations make it possible to freely select attachment mounting surfaces on the fingers., ESCAPEMENT, SGL FINGER, ESCAPEMENT, 1400 lb

Fluid:air; CO 2 ; nitrogen gas; freon 11, 113, 114; turbine oil, hydraulic fluid, argon, helium, Proof pressure: 1.5MPa, Operating pressure range: 0 to 1MPa, Effective area: 13 to 770mm 2, Coil rated voltage: AC(50/60Hz) 100V, 200V, others (option); DC 24V, others (option), Ambient temperature: -5 to 60°C (no freezing), Process valve, 2 PORT PROCESS VALVE, J07, 1400 lb

typeOperating temperature range [nC]Operating humidity range [%RH]Motor output/SizeMotor typeEncoderPowerconsumption [W] Note 5)Standby power consumption when operating [W] Note 6)Max. instantaneous power consumption [W] Note 7)Type Note 8)Holding force [N]Power consumption at 20nC [W] Note 9)Rated voltage [V]HorizontalVerticalLEFB40S4300, 400, 500600, 700, 800900, 1000, (1100)1200, (1300, 1400

typeOperating temperature range [nC]Operating humidity range [%RH]Motor output/SizeMotor typeEncoderPowerconsumption [W] Note 5)Standby power consumption when operating [W] Note 6)Max. instantaneous power consumption [W] Note 7)Type Note 8)Holding force [N]Power consumption at 20nC [W] Note 9)Rated voltage [V]HorizontalVerticalLEFB40S4300, 400, 500600, 700, 800900, 1000, (1100)1200, (1300, 1400

typeOperating temperature range [nC]Operating humidity range [%RH]Motor output/SizeMotor typeEncoderPowerconsumption [W] Note 5)Standby power consumption when operating [W] Note 6)Max. instantaneous power consumption [W] Note 7)Type Note 8)Holding force [N]Power consumption at 20nC [W] Note 9)Rated voltage [V]HorizontalVerticalLEFB32S3300, 400, 500600, 700, 800900, 1000, (1100)1200, (1300, 1400

typeOperating temperature range [nC]Operating humidity range [%RH]Motor output/SizeMotor typeEncoderPowerconsumption [W] Note 5)Standby power consumption when operating [W] Note 6)Max. instantaneous power consumption [W] Note 7)Type Note 8)Holding force [N]Power consumption at 20nC [W] Note 9)Rated voltage [V]HorizontalVerticalLEFB32S3300, 400, 500600, 700, 800900, 1000, (1100)1200, (1300, 1400

Cylinder (Tube) Inner Diameter(φ): 125, Stroke(mm): 1400, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): 0~70, End Locking: [Included] Presence, Valves: No, Operating Pressure

Cylinder (Tube) Inner Diameter(φ): 180, Stroke(mm): 1400, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): 0~70, End Locking: [Included] Presence, Valves: No, Operating Pressure

Cylinder (Tube) Inner Diameter(φ): 125, Stroke(mm): 1400, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: With fall prevention function / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): 0~70, End Locking: [Included] Presence, Valves: No, Operating Pressure

Cylinder (Tube) Inner Diameter(φ): 125, Stroke(mm): 1400, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Double rod, Main Body Shape: Standard, Additional Function: With fall prevention function / With Intermediate Stop Function, Environment, Applications: Standard, Operating Temperature(°C): 0~70, End Locking: [Included] Presence, Valves: No, Operating Pressure