Operation < Valve opened > When the coil u is energized the opened pilot A closes, the pressure in the pressure action chamber B rises and the main valve C closes. < Valve closed > When the coil u is not energized, the closed pilot valve A opens, the pressure in the pressure action chamber B drops and the main valve C opens.

Rod end nut L1 Double clevis type/CBQ2D, CDBQ2D (mm) Double clevis type CT 4N Cap bolt With rear lock With front lock Bore size (mm) CD CT CU CD hole H10 Shaft d9 A B CL A B CL 102.5 65.5 92.5 95 58 85 10 5 14 32 114 75 104 103.5 64.5 93.5 10 6 14 40 121.5 75.5 111.5 111.5 65.5 101.5 14 7 20 50 RR CW CU CX + 0.4 + 0.2 129 77 115 123 71 109 14 8 20 63 L B + Stroke CL + Stroke A + Stroke CZ

5 CYP32 (Nm) M1 M2 M1 0.3 3 M2 0.6 4 M3 0.3 3 Model CYP15 CYP32 m m Static moment Moment generated by the work piece weight even when the cylinder is stopped M Pich moment M1 = m x g x (L + B) x 103 M Yaw moment M3 = m x g x (L + A) x 103 M Roll moment M2 = m x g x (L + B) x 103 (mm) Model CYP15 CYP32 A 16.5 27.0 B 25.5 48.0 L B L B L A M1, 2, 3 : Moment [Nm] m : Load mass [kg] L : Distance

5 CYP32 (Nm) M1 M2 M1 0.3 3 M2 0.6 4 M3 0.3 3 Model CYP15 CYP32 m m Static moment Moment generated by the work piece weight even when the cylinder is stopped M Pich moment M1 = m x g x (L + B) x 103 M Yaw moment M3 = m x g x (L + A) x 103 M Roll moment M2 = m x g x (L + B) x 103 (mm) Model CYP15 CYP32 A 16.5 27.0 B 25.5 48.0 L B L B L A M1, 2, 3 : Moment [Nm] m : Load mass [kg] L : Distance

The number of sampling locations NL = (A) 0.5 Evaluation method using a simple sampling Number of sampling w Unidirectional airflow: at least two locations Smaller value between NL=A/2.32 and NL=A x 64/(10M) 0.5 locations At least one location 2 litters or a sufficient volume of air that a minimum of 20 particles could be counted if the particle concentration were at the class limit.

5 CYP32 (Nm) M1 M2 Model CYP15 CYP32 M1 0.3 3 M2 0.6 4 M3 0.3 3 m m Static moment Moment generated by the work piece weight even when the cylinder is stopped Pich moment M1 = m x g x (L + B) x 103 Yaw moment M3 = m x g x (L + A) x 103 Roll moment M2 = m x g x (L + B) x 103 (mm) Model CYP15 CYP32 A 16.5 27.0 B 25.5 48.0 L B L B L A M1, 2, 3 : Moment [Nm] m : Load mass [kg] L : Distance

: D-M9BV, D-M9NV, D-M9PV, D-F9WV (mm) B E B Stroke Model Stroke A 100 75 50 30 20 10 100 75 50 30 20 10 MXF8 13.5 6 1 6 14 9 14 MXF12 16 25.1 9.1 9.1 33.1 17.1 17.1 MXF16 21.2 42.3 21.8 11.8 50.8 29.8 19.8 MXF20 23.4 66.7 42.2 18.7 16.7 74.7 50.2 26.7 24.7 ( ): Denotes the values of D-A93.

In-line type AS1001F AS2001F AS2051F AS3001F AS4001F 6 to 20 20 to 32 20 to 40 40 to 63 63 to 100 Dual speed controller ASD230F ASD330F ASD430F ASD530F ASD530F ASD630F 6 to 20 20 to 32 20 to 40 20 to 40 40 to 63 63 to 100 M5 1/8 1/4 1/4 3/8 1/2 Applicable cylinder bore size (mm) Piping side port size Cylinder side port size Model AS1200 AS2200 AS3200 AS4200 M5 1 2 1/8 1/4 3/8 1/2 3/4 1 1

For driving air operated valves for fluid control N.C N.O N.C N.C Air operated style fluid control valve Vacuum valve Vacuum pad A, B 1(P) A, B 1(P) A, B 1(P) A, B 3(P) 3(R) 3(R) 3(R) 1(R) Vacuum releasing air Atmospheric pressure or micro pressure The characteristic values shown in the catalog are representative values, not warranting the performance. 4-3-1 2 Series SY100 Precautions Be

250 L/min ) [cm] -38No.PF-OMN0009CN-F PF3W504S PF3W520S [] [] P: P: PF3W540S [] P: -39No.PF-OMN0009CN-F () (PF3W504/520/540) A B C 1 V 1.5 V 5 V 4 mA 6 mA 20 mA (PF3W511) A B C 1 V 1.4 V 5 V 4 mA 5.6 mA 20 mA (PF3W521-12/14) A B C 1 V 1.8 V 5 V 4 mA 7.2 mA 20 mA (PF3W521-U30) A B C 1 V 1.48 V 5 V 4 mA 5.92 mA 20 mA [L/min] PF3W504 0.5 4 PF3W520 2 16 PF3W540 5 40 PF3W511 10 100 PF3W521

Model Exhaust Piping/Port location Port size Applicable P R 1 A,B P It A,B Valve NWsF5-20Common Side /Base Side/Base fop/ Valve %NPrF I %flPlf LNPIF %NPIF NVFSO20 DXT 156-20-1TA EXH relocation spacer NVV5F5-20 156-19-14 NW5F5-20 " Spacer is used when it is nscessary to exhaust from certain valves individually.

An ideal air cylinder for lifting and pressing operations Air pressure supplied from A operates on surfaces 1 and 2. (extension) A B Air pressure supplied from B operates on surface 3. (retraction) A B Mounting accuracy improved Positioning holes are provided on the work piece mounting surface for easy alignment.

sealing method Options Flat gasket (D.O.E) 1 N/A Bracket Quick plug Nil B P Note) Specity seal material in place of "" (N for NBR or V for FPM). 4.

Features 2 Model Selection 1 Obtain the correction factor for the temperature from data A or B and the correction factor for the air pressure from data C. Temperature Data A or B = Series IDU: Data A IDF1D to 240D: Data B-1 IDF 370B: Data B-2 Air pressure Data C = Series IDU and Series IDF: Data C 2 Calculate corrected air flow by using A or B and C.

AS-FE 1/8 0.07 1/4 0.16 KE 3/8 0.2 1/2 0.4 AS-FG When performing the piping work, turn the tightening tool in the horizontal direction to the hexagon across flats of the body B so that any moment is not applied to the body A. If the tool is in contact with the body A, this may cause the body B to come off. AS-FP AS-FM 4.

4 2 5 A 10 x 8 3/4" x 5/8" 5 1 5 B 19 x 16 1/2" x 3/8" 5 2 6 A 12 x 10 1" x 7/8" SMC 6 1 6 B 25 x 22 3/4" x 5/8" 6 2 19 x 16 : Basic size : With reducer Note) Please select an isometric fitting with the same size as the fitting at the flow sensor.

Round plate (Including column) Position of rotational axis: Through the center (A) Number of axis teeth =a (B) 1. Find the moment of inertia I for the rotation of shaft (B). B r 2. I is converted to the rotation of the shaft (A). B 2 r I = m2 2 b a I I = A B Number of teeth =b 5.

A W K 2-Plug H HA CB 2-P (Piping port) Y HP Counter bore depth C 4-counter bore B T T 4-J x E 0 -0.1 L Cylinder tube outer circumference: TC Hard chrome plated + special treatment WP X F GW GP 4-LD D QW PW 2 x 4-MM thread depth M W K G G Q + Stroke Z + Stroke (mm) Model B C CB D F G GP GW H HA HC HP HB HT K J x E A 10.5 181. 16.6 181. 5 33 31.5 32 30 171. 31 171. 2 4.2 171. 14 M5 x 0.8 x

W B D-A9, D-A9V D-M9, D-F9W D-M9V, D-F9WV Bore size (mm) B A W A B W A 10 16 20 25 32 0.5 7.5 2.5 7.5 16.5 3 12.5 16.5 1.5 (1) 0 8 1.5 8 20 4 16 20 2 (0.5) 2 10 0 10 24 6 20 24 4 (1.5) 3.5 11.5 1.5 11.5 26.5 7 22.5 26.5 5.5 (3) 4.5 12.5 2.5 12.5 27.5 8 23.5 27.5 6.5 (4) Note 1) Figures in the table above are used as a reference when mounting the auto switches for stroke end detection.

B IDFB4E to 15E A Power cable outlet 0.7 [17 mm] Grommet with membrane Signal cable outlet 0.7 [17 mm] Terminal block (Wire diameter 0.4 [9 to 11mm]) Grommet with membrane Power cable outlet 0.7 [17 mm] IDFB4E to 11E_Terminal block C D A B Terminal block Dimensions Unit: inch [mm] A B C D Model B B 9.0 [230] 2.6 [67] 7.0 [179] 1.3 [32] IDFB4E, 6E, 8E, 11E A Power cable outlet 0.7 [17 mm]