SMC Corporation of America
Elite Part Number Search
Search Results "ISE20B-L-01-D"

Function: 2 (2 Position Double), Piping: 3 (Body Ported), Exhaust: 3 (Common), Low Wattage: None, Pressure Specification: Standard (0.7MPa), Coil Specification: Standard, Voltage: 5 (24VDC), Lead Wire: L (L Plug Connector w/Lead Wire 300mm), Light/Surge Suppressor: Without light/surge voltage suppressor, Manual Override: D (Push-turn Locking Slotted Type), A, B Port Size: 01 (1/8), Thread

E F G H I J ASCII code 4BH 4CH 4DH 4EH 4FH 50H 51H 52H 53H 54H Character used K L M N O P Q R S T ASCII code 55H 56H 57H 58H 59H 5AH Character used U V W X Y Z HEF002-A6 3-9 Troubleshooting 4 Troubleshooting The table below shows the solutions for the problems.

E F G H I J ASCII code 4BH 4CH 4DH 4EH 4FH 50H 51H 52H 53H 54H Character used K L M N O P Q R S T ASCII code 55H 56H 57H 58H 59H 5AH Character used U V W X Y Z INR-244-831 3-9 Troubleshooting 4 Troubleshooting The table below shows the solutions for the problems.

Stations: 01 (1 Station), Piping: D (U Side: Closed; D Side: Open), Thread Type: N (NPT), Supply Unit Components: P (w/o Flow Adj. Valve; w/Stop Valve), Return Unit Flow Range: 40 (5 to 40 L/min), Supply/Return Port Size: 06 (3/4)

Stations: 01 (1 Station), Piping: D (U Side: Closed; D Side: Open), Thread Type: N (NPT), Supply Unit Components: W (w/Flow Adj. Valve; w/Stop Valve), Return Unit Flow Range: 20 (2 to 16 L/min), Supply/Return Port Size: 04 (1/2)

Stations: 01 (1 Station), Piping: D (U Side: Closed; D Side: Open), Thread Type: N (NPT), Supply Unit Components: P (w/o Flow Adj. Valve; w/Stop Valve), Return Unit Flow Range: 20 (2 to 16 L/min), Supply/Return Port Size: 03 (3/8)

Stations: 01 (1 Station), Piping: D (U Side: Closed; D Side: Open), Thread Type: N (NPT), Supply Unit Components: P (w/o Flow Adj. Valve; w/Stop Valve), Return Unit Flow Range: 40 (5 to 40 L/min), Supply/Return Port Size: 04 (1/2)

Stations: 01 (1 Station), Piping: D (U Side: Closed; D Side: Open), Thread Type: N (NPT), Supply Unit Components: S (w/Flow Adj. Valve; Stop Valve: None), Return Unit Flow Range: 40 (5 to 40 L/min), Supply/Return Port Size: 06 (3/4)

Stations: 01, Systems, Port Combinations: A [Ejector System, ø8 (Common PV)], Exhaust: 2 (Individual Exhaust), Wiring: F (D-sub Connector), Bracket: B (w/DIN Rail Mounting Bracket), Common Release Pressure Supply: D [w/Common Release Pressure Supply (PD) Port], Manifold Individual Supply: L (Manifold Individual Supply Specification)

Model (Standard) Model Pressure range (1) Green zone setting range Indication unit Connection thread Note MPa Minimum setting range (MPa) Maximum setting range (MPa) G36-2-01-L G36-4-01-L G36-10-01-L G46-2-01 to 02-L G46-4-01 to 02-L G46-10-01 to 02-L 0 to 0.2 0.01 0.1 R 1/8 0 to 0.4 0.02 0.2 0 to 1.0 0.05 0.5 MPa 0 to 0.2 0.01 0.1 R 1/8, 1/4 0 to 0.4 0.02 0.2 0 to 1.0 0.05 0.5 Note 1) Do

Actuation: 1 (2-Position Single), Electrical Entry: TT (Terminal Type), Lead Wire Length: 6 (600mm, Maximum Length for L-type), Manual Override: D (Push-turn Locking Slotted Type), A,B Port: 01 (1/8), Thread Type: N (NPT), Bracket: F2 (w/Side Bracket)

Output Specification: P (PNP Open Collector 1 Output), Unit Specification: w/Unit Selection Function, Piping Specification: 01 (R 1/8), Option 1: L (Lead Wire w/Connector, 2m), Option 2: D (Panel Mount Adapter + Front Protection Cover), Option 3: K (Operation Manual, Calibration Certificate)

Model: 31, Orifice: 2 (2.2mm), Style: 4 (COM, Single Unit), Option: C37, Seals: NBR, Class B, Suffix: Standard, Port Size: 01 (1/8), Thread: N (NPT), Voltage: 5 (24VDC), Electrical Entry: D (DIN Terminal), Surge Suppressor: L (w/Light), Rectifier: None (for DC or AC Class H Coil)

Example 1) When the pressure in the rear and the front of the cylinder differs: Example 2) When the air supply is cut off and releasing the inlet pressure to the atmosphere, the residual pressure release of the outlet side can be ensured for a safety purpose. 1 1 2 12 2 1 2 1 3 1 2 1 14 2 4 12 L 10 5 1 3 How to Order ARP 30 03 BE K Option / Semi-standard: Select one each for a to f.

(Metric size) ASV 4 6 6 10 8 4 Flow rate [L/min (ANR)] It may damage the body A or fittings.

Note) Metric size 23 04 06 08 10 12 Inch size 3.2 01 03 05 07 09 11 13 1/8" 5/32" 3/16" 1/4" 5/16" 3/8" 1/2" 4 6 8 10 12 Made to Order (For details, refer to page 622.)

E Socket/Plug designation S P Socket Plug Piping port size variation Male/Female thread type One-touch fitting type Nut fitting type Thread size M5 x 0.8 R, Rc 1/8 R, Rc 1/4 R, Rc 3/8 R, Rc 1/2 R, Rc 3/4 Symbol M5 01 02 03 04 06 Symbol 23 04 06 08 10 12 16 Symbol 50 60 65 80 85 110 Applicable tubing O.D. mm 3.2 4 6 8 10 12 16 Applicable hose I.D.

Stations: 01 (1 Station), Piping: U (U Side: Open; D Side: Closed), Thread Type: N (NPT), Supply Unit Components: P (w/o Flow Adj. Valve; w/Stop Valve), Return Unit Flow Range: 20 (2 to 16 L/min), Supply/Return Port Size: 03 (3/8)

Rated Flow Range: 01 (0.01 to 1 L/min), Flow Adjustment Valve: None (Straight), Port Size: N1 (NPT1/8), Output Specification: D (Out 1: NPN; Out 2: Analog 4 to 20 mA)