-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com (KB) D-A7/A8 Auto switch KA A + Stroke B + Stroke W L S EA EB EC M J 2 x 2-OA 2 x 2-RA Both ends tapped style (CQMA) (mm) Without auto switch With auto switch Stroke range (mm) Bore size (mm) P P EA EB EC B F Q A B F Q A TN TF NN NN TN TF 5 5.5 11.5 M5 x 0.8 M5 x 0.8 40 23 32 10 to 50 50 33
Please contact SMC for more information. 9-13-6 6 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 9-13-7 7 Plate Cylinder with Lock Series MLU 25, 32, 40, 50 How to Order B 25 30 D F MLU Without auto switch With auto switch B 25 30 D F J79W S MDLU Number of auto switches
Reference formulas [Dynamic moment at impact] Use the following formulas to calculate dynamic moment when taking stopper impact into consideration. m : Load weight (kg) F : Load (N) FE : Load equivalent to impact (at impact with stopper) (N) a : Average speed (mm/s) M : Static moment (Nm) = 1.4a (mm/s) FE = 1.4a x x m g : Impact speed (mm/s) L1 : Distance to the loads center of gravity
Operating humidity range (%) Storage temperature range (F) Storage humidity range (%) Insulation resistance (M) Between the housing (radiation fin) and SG terminal 50 (500 VDC) 0.3 (Screw mounting) 0.4 (DIN rail mounting) Weight (lb) Note 1) Do not use the power supply of inrush current prevention type for the controller power supply.
Decimal display Hexadecimal display 10 A 11 b 12 c 13 d 14 E 15 F Note 4) Applicable to non-magnetizing lock. 576 Programless Controller LECP1 Series Controller Details e r No.
Reference: 1 [L/min] = 0.2642 [gal/min] 1 [gal/min] = 3.785 [L/min] Thread type Symbol Type Nil Rc N NPT F G The close proximity setting and zero-reset setting functions are only available for the integrated display type. For the remote type sensor unit, the close proximity setting and zeroreset setting functions cannot be used. Option/Part No.
E 16 outputs D-sub connector (25 pins) F 16 outputs Spring type terminal block (32 pins) * For specifications, refer to the Fieldbus system EX600 series in the Web Catalog.
Regeneration SF SFD Electric circuit Time chart LLB Power supply (refer to How to Order) Power supply (refer to How to Order) AD Inlet air temperature (C) (Saturation) 1 cycle 1 cycle SW F SOL.1 SW F SOL.1 LS1 LS1 GD IDseries Adsorbent/Silica alumina gel ID-Z series Adsorbent/Permutite SV SV SOL.2 LS2 SOL.2 LS2 SV SV R M M PL PL For ID05, ID06 For ID00, ID01 Symbol Description Description
Clean series 10 AF 03 A 30 F J B 21 AF 03 A 30 F J B Copper, fluorine and silicone-free + Low particle generation q w e r t Air filter Option/Semi-standard: Select one each for a to e. Option/Semi-standard symbol: When more than one specification is required, indicate in alphanumeric order.
6, 10, 15, 20, 25, 32 Dual Rod Cylinder Series CXS 10-/11-/1221-/22Air Preparation Equipment Pressure Control Equipment Flow Control Equipment Pressure Switches/ Pressure Sensors Directional Control Valves Air Grippers Modular F. R.
Please consult with SMC separately for psi and F unit display specifications. Bowl assembly for the AFJ30 and AFJ40 models comes with a bowl guard (Material: Polycarbonate).
Example 1) When the pressure in the rear and the front of the cylinder differs: Example 2) When the air supply is cut off and releasing the inlet pressure to the atmosphere, the residual pressure release of the outlet side can be ensured for a safety purpose. 1 1 2 12 2 1 2 1 3 1 2 1 14 2 4 12 L 10 5 1 3 How to Order ARP 30 03 BE K Option / Semi-standard: Select one each for a to f.
Example 1) When the pressure in the rear and the front of the cylinder differs: Example 2) When the air supply is cut off and releasing the inlet pressure to the atmosphere, the residual pressure release of the outlet side can be ensured for a safety purpose. 1 1 2 12 2 1 2 1 3 1 2 1 14 2 4 12 L 10 5 1 3 How to Order ARP 30 03 BE K Option / Semi-standard: Select one each for a to f.
Example) 10-ARP30K-03BE-1RY Clean room compliant, copperfree, fluorine-free, silicon-free Clean room compliant Copper-free, fluorine-free Symbol 20 30 40 Body size Description 20 30 40 Body size 20 30 40 Body size Nil K Without backflow function With backflow function With backflow function + Nil N F Thread type Rc NPT G + 01 02 03 04 1/8 1/4 3/8 1/2 Port size + Nil B Note 2) H a Without
(Example for 4 L/min type the above ) In measurement mode, when the button is pressed for 2 seconds or longer, [F 1] is displayed. This [F ] indicates the mode for changing each functional setting.
Function selection mode In measurement mode, press the SET button for 3 to 5 seconds to display [F ] on the main screen. Select to display the function to be change [F ].
Model number: HRS040-F-20 The transition connector from Rc to G is enclosed as an accessory. For G piping, be sure to use this connector.
Model number: HRS050-F-20 The transition connector from Rc to G is enclosed as an accessory. For G piping, be sure to use this connector.
Unused bit is fixed to 0. 1: These alarms do not occur on the product of the cooling method -W. 4.10 Register Map HRS090 Series 4-20 HRX-OM-T004 Chapter 4 MODBUS communication function 4.10.7 Circulating fluid set temperature The circulating fluid set temperature can be set by specifying the circulating fluid set temperature with the selected temperature unit (C or F) during SERIAL mode.
Unused bit is fixed to 0. 4.10 Register Map HRSH Series 4-20 HRX-OM-R028 Chapter 4 MODBUS communication function 4.10.5 Circulating fluid set temperature The circulating fluid set temperature can be set by specifying the circulating fluid set temperature with the selected temperature unit (C or F) during SERIAL mode.