SOL VALVE 4/5 PORT, 2D, VZS2000, .30800 lb, Type of actuationModelPort size RcFlow characteristics(1)Max. operatingcycle (CPM)(2)Responsetime (ms)(3)Weight(kg) 1 4/2 (P A/B)4/2 5/3 (A/B R1/R2) C [dm3/(s?
5/3 (A/B R1/R2)Standard(0.4 W)Quick response(0.95 W) C [dm3/(s?
Part Number Description: SUBPLATE ISO 5599-2 SIZE 2 Product Line: V Product Line Description: VALVE Family Code: 264 Family Description: VS7-8 SOL VALVE 4/5 PORT Class Code: R1 Part Code: 2 Reference Code: J Click here to report information errorImage shown may not match exact part number, ModelPorting specificationsWeight (kg) Piping locationPort sizeVS7-2-B04Bottom1/20.68
5/3 (A/B R1/R2)Standard(0.4 W)Quick response(0.95 W) C [dm3/(s?
Rated Pressure Range: H (-0.1 to 2 MPa), Output Specification: Y (PNP Open Collector 2 Outputs + Copy Function), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: 02 [R1/4, (M5, Female Threaded)], Piping Direction: L (Bottom Ported), Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof), Bracket: A3 (Bracket C)
Rated Pressure Range: -0.1 to 2 MPa, Piping: R1/4, M5 Female, Rear Ported, Input/Output: NPN Open Collector 2 Outputs, Option 1: Fixed SI Unit, Option 2: Panel Mount + Front Protection Cover, Option 3: Calibration Certificate, X Options: -
Rated Pressure Range: -0.1 to 2 MPa, Piping: R1/4, M5 Female, Rear Ported, Input/Output: NPN Open Collector 2 Outputs, Analog Voltage Output, Auto-Shift, Option 1: w/Unit Display Switching Function, Option 2: Panel Mount Rear or Bottom Ported, Option 3: Operating Manual Booklet+Calibration Certificate, X Options: -
Rated Pressure Range: -0.1 to 2 MPa, Piping: R1/4, M5 Female, Rear Ported, Input/Output: NPN Open Collector 2 Outputs, Analog Voltage Output, Auto-Shift, Option 1: Initial Value PSI, Option 2: w/Bracket Rear Ported Only, Option 3: -, X Options: -
Rated Pressure Range: -0.1 to 2 MPa, Piping: R1/4, M5 Female, Rear Ported, Input/Output: NPN Open Collector 2 Outputs, Analog Current Output, Auto-Shift, Option 1: w/Unit Display Switching Function, Option 2: Panel Mount + Front Protection Cover, Option 3: Operating Manual Booklet+Calibration Certificate, X Options: -
Rated Pressure Range: -0.1 to 2 MPa, Piping: R1/4, M5 Female, Rear Ported, Input/Output: NPN Open Collector 2 Outputs, Analog Current Output, Auto-Shift, Option 1: Initial Value PSI, Option 2: Panel Mount + Front Protection Cover, Option 3: Operating Manual Booklet+Calibration Certificate, X Options: -
Rated Pressure Range: -0.1 to 2 MPa, Piping: R1/4, M5 Female, Rear Ported, Input/Output: NPN Open Collector 2 Outputs, Analog Current Output, Auto-Shift, Option 1: Initial Value PSI, Option 2: None, Option 3: Calibration Certificate, X Options: -
Rated Pressure Range: -0.1 to 2 MPa, Piping: R1/4, M5 Female, Rear Ported, Input/Output: PNP Open Collector 2 Outputs, Analog Voltage Output, Auto-Shift, Option 1: w/Unit Display Switching Function, Option 2: w/Bracket Rear Ported Only, Option 3: -, X Options: -
Rated Pressure Range: -0.1 to 2 MPa, Piping: R1/4, M5 Female, Rear Ported, Input/Output: PNP Open Collector 2 Outputs, Analog Voltage Output, Auto-Shift, Option 1: Fixed SI Unit, Option 2: -, Option 3: -, X Options: -
Rated Pressure Range: -0.1 to 2 MPa, Piping: R1/4, M5 Female, Rear Ported, Input/Output: PNP Open Collector 2 Outputs, Analog Current Output, Auto-Shift, Option 1: Initial Value PSI, Option 2: Panel Mount + Front Protection Cover, Option 3: Calibration Certificate, X Options: -
Rated Pressure Range: -0.1 to 2 MPa, Piping: R1/4, M5 Female, Rear Ported, Input/Output: PNP Open Collector 2 Outputs, Analog Current Output, Auto-Shift, Option 1: Initial Value PSI, Option 2: None, Option 3: Calibration Certificate, X Options: -
Rated Pressure Range: -0.1 to 2 MPa, Piping: R1/4, M5 Female, Bottom Ported, Input/Output: NPN Open Collector 2 Outputs, Option 1: Fixed SI Unit, Option 2: Panel Mount + Front Protection Cover, Option 3: Operating Manual Booklet+Calibration Certificate, X Options: -
Rated Pressure Range: -0.1 to 2 MPa, Piping: R1/4, M5 Female, Bottom Ported, Input/Output: NPN Open Collector 2 Outputs, Option 1: Fixed SI Unit, Option 2: None, Option 3: Operating Manual Booklet+Calibration Certificate, X Options: -
Rated Pressure Range: -0.1 to 2 MPa, Piping: R1/4, M5 Female, Bottom Ported, Input/Output: PNP Open Collector 2 Outputs, Option 1: w/Unit Display Switching Function, Option 2: w/Bracket Rear or Bottom Ported, Option 3: -, X Options: -
Rated Pressure Range: -0.1 to 2 MPa, Piping: R1/4, M5 Female, Bottom Ported, Input/Output: PNP Open Collector 2 Outputs, Option 1: w/Unit Display Switching Function, Option 2: w/Bracket Rear or Bottom Ported, Option 3: Operating Manual Booklet+Calibration Certificate, X Options: -
Rated Pressure Range: -0.1 to 2 MPa, Piping: R1/4, M5 Female, Bottom Ported, Input/Output: PNP Open Collector 2 Outputs, Option 1: w/Unit Display Switching Function, Option 2: Panel Mount Rear or Bottom Ported, Option 3: -, X Options: -