Seal Type: Metal, Configuration: 2-position, Number of Solenoids: Double, Voltage: 24VDC, Pilot: External Individual Pilot Exhaust, Subplate: Side 1/2, Option: -
Seal Type: Metal, Configuration: 2-position, Number of Solenoids: Double, Voltage: 24VDC, Pilot: External Individual Pilot Exhaust, Subplate: Side 3/8, Option: -
Seal Type: Metal, Configuration: 2-position, Number of Solenoids: Double, Voltage: 24VDC, Pilot: External Individual Pilot Exhaust, Subplate: Side 3/4, Option: -
Seal Type: Metal, Configuration: 2-position, Number of Solenoids: Double, Voltage: 24VDC, Pilot: External Individual Pilot Exhaust, Subplate: -, Option: -
Seal Type: Metal, Configuration: 2-position, Number of Solenoids: Double, Voltage: 100VAC/50Hz, 115VAC/60HZ, Pilot: External Individual Pilot Exhaust, Subplate: -, Option: -
Seal Type: Metal, Configuration: 2-position, Number of Solenoids: Double, Voltage: 100VAC/50Hz, 115VAC/60HZ, Pilot: Pilot Exhaust through Footprint, Subplate: w/o Subplate, Option: External Pilot Supply
Seal Type: Metal, Configuration: 2-position, Number of Solenoids: Double, Voltage: 100VAC/50Hz, 115VAC/60HZ, Pilot: External Individual Pilot Exhaust, Subplate: Side 3/4, Option: -
Seal: Metal, Size: Size 26mm, Configuration: 2-position, Number of Solenoids: Double, Voltage: 24VDC, Light/Surge Voltage Suppressor: Indicator Light, Surge Voltage Suppressor, Manual Override: Push Type, Internal/External Pilot: External Pilot, CE Compliant: CE Compliant
size 1, 2 and 3 are?plug-in, base mounted interface valves conforming to ISO standards. The valve design offers maximum flexibility and is available in either a high flow rubber seal (model VSR), or matched ground spool and sleeve (model VSS). The lateral plug-in style manifold makes it easy to increase or decrease the manifold stations without wiring work.?
VALVE, ISO, VALVE, VSS/R8-6 SOL VALVE 4/5 PORT, 2D, VSS/R8-6 NO SIZE RATING, 0.66925 lb
1/8, 1/4 standard 3/8 standard 1/2 standard Applicable tubing O.D.
If the difference between Set point 1 and Set point 2 is less than "6% of maximum rated flow", the maximum Set value of hysteresis is (Set point 1 Set point 2) divided by 2. 2: When Set point 1 = Set point 2, chattering may occur.
This product is not designed to be explosion proof. 2 OUT2 White 3 DC(-) Blue U P U P SET 1: In window comparator mode, the hysteresis is fixed at 3 digits. When setting, allow 7 digits or more between Set point 1 and Set point 2 (Set point 3 and Set point 4). 2: When Set point 1 = Set point 2 (Set point 3 = Set point 4), chattering may occur.
Input of the Set point 2 L/min, L CFM x 10-2, CFM x 10-1, ft3 x 10-2, ft3 x 10-1, gal(US)/min, gal(US) 1 Brown DC(+) Non-Reverse output Reverse output Refer to the product catalogue or SMC website (URL http://www.smcworld.com) for more information about panel cut-out dimensions.
When setting, allow 7 digits or more between Set point 1 and Set point 2 (Set point 3 and Set point 4). 2: When Set point 1 = Set point 2 (Set point 3 = Set point 4), chattering may occur. Set value is calculated and set. Set value 4 Set value or 3 or 3 Measurement mode Do not use the product in a place where static electricity is a problem.
Delay time setting can prevent the output from chattering. (5) Press the button for 2 seconds or longer to complete the setting. : If the button is pressed for less than 2 seconds, the setting will moves to the OUT2 setting.
Unit specifications Input/Output specifications NPN open collector 2 outputs + analog output NPN open collector 2 outputs + auto shift input PNP open collector 2 outputs + analog output PNP open collector 2 outputs + auto shift input With unit switching function Note1) 22 Nil 30* 62* 70* SI units only Note 2) M Note 1) This will no longer be sold for use in Japan after the new Weight and
[F 2] Setting of OUT2 Same setting as [F 1] OUT1. The direct current power supply to be used should be UL approved as follows: Circuit (of Class 2) which is of maximum 30 Vrms (42.4 V peak), with UL1310 Class 2 power supply unit or UL1585 Class 2 transformer. The product is a UL approved product only if it has a mark on the body. Press the SET button for 2 second or longer.
Dimensions AS420 AS500 AS600 67.5 74 90 1/4, 3/8, 1/2 3/4 1 38 42 55 122 115 158 112 105 148 50 50 62 L1 L2 L4 Min. L3 (1) Model Port size Max. 1 4 1 2 120 150 AS800 AS900 74 93 204 262 192 250 80 94 1 1 , 2 Note 1) L3: Reference dimensions Note 1) L3: Reference dimensions 655