Nozzle Diameter: ø1.0, Exhaust: Silencer, Valve: Supply Valve: Solenoid (NC)/Release Valve: Solenoid (NC), Voltage: 110VAC 50/60Hz, Electrical Entry: L Plug Lead Wire: 0.3m, Surge Suppressor: Light+Surge Suppressor, Manual Override: Non-locking Push Style (Or None if Air Operated or No Valve), Switch: Vacuum Switch, PNP, Lead Wire: Grommet Lead Wire 0.6m (Or None), Mounting Style: For Manifold
Nozzle Diameter: ø1.0, Exhaust: Silencer, Valve: Supply Valve: Solenoid (NC)/Release Valve: Solenoid (NC), Voltage: 24VDC, Electrical Entry: L Plug w/o Connector, Surge Suppressor: Light+Surge Suppressor, Manual Override: Locking Style Slotted, Switch: Vacuum Switch, PNP, Lead Wire: Grommet Lead Wire 0.6m (Or None), Mounting Style: For Manifold Use
Nozzle Diameter: ø1.0, Exhaust: Silencer, Valve: Supply Valve: Solenoid (NC)/Release Valve: Solenoid (NC), Voltage: 24VDC, Electrical Entry: L Plug Lead Wire: 0.3m, Surge Suppressor: Light+Surge Suppressor, Manual Override: Non-locking Push Style (Or None if Air Operated or No Valve), Switch: Vacuum Switch, PNP, Lead Wire: Grommet Lead Wire 0.6m (Or None), Mounting Style: For Manifold Use
Nozzle Diameter: ø1.0, Exhaust: Silencer, Valve: Supply Valve: Air Operated (NC)/Release Valve: External Release, Voltage: Air Operated (Or No Valve), Electrical Entry: Air Operated (Or No Electrical Entry), Surge Suppressor: None, Manual Override: Non-locking Push Style (Or None if Air Operated or No Valve), Switch: Vacuum Switch, PNP, Lead Wire: Grommet Lead Wire 0.6m (Or None), Mounting
Nozzle Diameter: ø1.0, Exhaust: 3 [Common Exhaust (Only Manifold)], Valve: Supply Valve: Solenoid (NC)/Release Valve: Solenoid (NC), Voltage: 24VDC, Electrical Entry: L Plug w/o Connector, Surge Suppressor: Light+Surge Suppressor, Manual Override: Non-locking Push Style (Or None if Air Operated or No Valve), Switch: Vacuum Switch, PNP, Lead Wire: Grommet Lead Wire 0.6m (Or None), Mounting
Nozzle Diameter: ø1.0, Exhaust: 3 [Common Exhaust (Only Manifold)], Valve: Supply Valve: Solenoid (NC)/Release Valve: Solenoid (NC), Voltage: 24VDC, Electrical Entry: L Plug Lead Wire: 0.3m, Surge Suppressor: Light+Surge Suppressor, Manual Override: Locking Style Slotted, Switch: Vacuum Switch, PNP, Lead Wire: Grommet Lead Wire 0.6m (Or None), Mounting Style: For Manifold Use
Nozzle Diameter: ø1.3, Exhaust: Silencer, Valve: Supply Valve: Solenoid (NC)/Release Valve: Solenoid (NC), Voltage: 24VDC, Electrical Entry: L Plug Lead Wire: 0.3m, Surge Suppressor: Light+Surge Suppressor, Manual Override: Non-locking Push Style (Or None if Air Operated or No Valve), Switch: Vacuum Switch, PNP, Lead Wire: Grommet Lead Wire 0.6m (Or None), Mounting Style: For Manifold Use
Nozzle Diameter: ø1.3, Exhaust: 3 [Common Exhaust (Only Manifold)], Valve: Supply Valve: Solenoid (NC)/Release Valve: Solenoid (NC), Voltage: 24VDC, Electrical Entry: L Plug w/o Connector, Surge Suppressor: Light+Surge Suppressor, Manual Override: Non-locking Push Style (Or None if Air Operated or No Valve), Switch: Vacuum Switch, PNP, Lead Wire: Grommet Lead Wire 0.6m (Or None), Mounting
Nozzle Diameter: ø1.3, Exhaust: 3 [Common Exhaust (Only Manifold)], Valve: Supply Valve: Solenoid (NC)/Release Valve: Solenoid (NC), Voltage: 24VDC, Electrical Entry: L Plug Lead Wire: 0.3m, Surge Suppressor: Light+Surge Suppressor, Manual Override: Non-locking Push Style (Or None if Air Operated or No Valve), Switch: Vacuum Switch, PNP, Lead Wire: Grommet Lead Wire 0.6m (Or None), Mounting
Nozzle Diameter: ø0.7, Exhaust: 3 [Common Exhaust (Only Manifold)], Valve: Supply Valve: Solenoid (NC)/Release Valve: Nil, Voltage: 24VDC, Electrical Entry: L Plug Lead Wire: 0.3m, Surge Suppressor: Light+Surge Suppressor, Manual Override: Non-locking Push Style (Or None if Air Operated or No Valve), Switch: Vacuum Switch, PNP, Lead Wire: Grommet Lead Wire 0.6m (Or None), Mounting Style:
Nozzle Diameter: 1.5 mm, Vacuum Pressure: -84 kPa, Exhaust: Built-in Silencer, Valve: NC + NC, Voltage: 24 VDC, Electrical Entry: M Plug Connector, Lead Wire Length 0.3 m, Surge Suppressor: Light + Surge Supressor, Manual Override: Non-locking Push Type, Switch/Filter: E [Pressure switch for Vacuum (ZSE2) + Filter], Output: PNP Open Collector, 1 Output, Unit Specification: Standard, Lead
Valve: Supply Valve: Solenoid (NC)/Release Valve: Solenoid (NC), Pilot Valve: DC 1W (With Light: 1.05 W); AC or None in Case of No Valve, Voltage: 24VDC, Electrical Entry: L Plug Lead Wire: 0.3m, Surge Suppressor: Light+Surge Suppressor, Manual Override: Non-locking Push Style (Or None if Air Pilot or No Valve), Switch: Vacuum Switch, PNP, Lead Wire: Grommet Lead Wire 0.6m (Or None), Port
Valve: Supply Valve: Solenoid (NC)/Release Valve: Solenoid (NC), Pilot Valve: DC 1W (With Light: 1.05 W); AC or None in Case of No Valve, Voltage: 24VDC, Electrical Entry: L Plug Lead Wire: 0.3m, Surge Suppressor: Light+Surge Suppressor, Manual Override: Non-locking Push Style (Or None if Air Pilot or No Valve), Switch: Vacuum Switch, PNP, Lead Wire: Grommet Lead Wire 0.6m (Or None), Port
Valve: Supply Valve: Solenoid (NO)/Release Valve: Solenoid (NC), Pilot Valve: DC 1W (With Light: 1.05 W); AC or None in Case of No Valve, Voltage: 24VDC, Electrical Entry: Grommet Lead Wire 0.6m, Surge Suppressor: Light+Surge Suppressor, Manual Override: Non-locking Push Style (Or None if Air Pilot or No Valve), Switch: Vacuum Switch, PNP, Lead Wire: Grommet Lead Wire 0.6m (Or None), Port
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, VACUUM GENERATOR, VACUUM SERIES, ZM VACUUM SYSTEM, FD, ZM NOZZLE SIZE 1.5, .66138 lb
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, VACUUM GENERATOR,HIGH PRESS/DC, VACUUM SERIES, ZM VACUUM SYSTEM, DC, ZM NOZZLE SIZE 1.3, 0.56245 lb
Main Body Shape: Square Shape, Additional Function: Filter / Valves for Vacuum Generation / Vacuum Destructive Valve, Ultimate Vacuum(kPa): -84, Air Consumption Flow Rate(l/min): 17, Vacuum Port Connecting Port Shape: Rc1/8, Air Supply Port Connecting Shape: Rc1/8, Application: Manifolds, Operating Pressure Range(MPa): null~0.7, Operating Temperature Range(°C): 5:50~, Suction Flow(l/min):
Nozzle Diameter: ø1.0, Body Style: Single Unit w/Valve + Standard Silencer, Vacuum Port Location: Side/Bottom Entry, Standard Supply Pressure: 0.5 MPa, Thread Type: Rc, Supply/Release Valve: Supply Valve+Release Valve, Solenoid Valve Rated Voltage: 24VDC, Electrical Entry: L Plug Connector w/0.3m Lead Wire, Light/Surge Voltage Suppressor: w/Light/Surge Voltage Suppressor, Manual Override:
Valve: Supply Valve: Solenoid (NC)/Release Valve: Solenoid (NC), Pilot Valve: DC 1W (With Light: 1.05 W); AC or None in Case of No Valve, Voltage: 24VDC, Electrical Entry: L Plug Lead Wire: 0.3m, Surge Suppressor: Light+Surge Suppressor, Manual Override: Non-locking Push Style (Or None if Air Pilot or No Valve), Switch: Vacuum Switch, PNP, Lead Wire: Grommet Lead Wire 0.6m (Or None), Port
The ZM series is an all-in-one vacuum generator, complete with internal suction filter, exhaust silencer, supply and break valve, and vacuum switch. Its dual-stage nozzle design increases suction flow by 40% over single-stage generators, yet its compact size makes it suitable for many different applications. ZM series generators also boast a strong vacuum break pressure for quick cycle times