Settable range of user set value Settable value range Range Lower limit Upper limit -10..+10 V -10.50 to +10.45 V -10.45 to +10.50 V -5..+5 V -5.25 to +5.22 V -5.22 to +5.25 V -20..+20 mA -21.00 to +20.90 mA -20.90 to +21.00 mA 0..10 V 0.00 to +10.45 V +0.05 to +10.50 V 0..5 V 0.00 to +5.22 V +0.03 to +5.25 V 1..5 V +0.75 to +5.22 V +0.78 to +5.25 V 0..20 mA 0.00 to +20.90 mA +0.10 to +21.00
(Range) (Lwr_Lmt) (Upr_Lmt) -10..10 V -10.50 to +10.45 V -10.45 to +10.50 V -5..5 V 5.25 to + 5.22 V 5.22 to +5.25 V -20..20 mA -21.00 to +20.90 mA -20.90 to +21.00 mA 0..10 V 0.00 to +10.45 V +0.05 to +10.50 V 0..5 V 0.00 to +5.22 V +0.03 to +5.25 V 1..5 V +0.75 to +5.22 V +0.78 to +5.25 V 0..20 mA 0.00 to +20.90 mA +0.10 to +21.00 mA 4..20 mA +3.00 to +20.90 mA +3.10 to +21.00 mA -51No.EX-OMN0030
) 2 0 V() 3 24 V() 4 0 V() 5 FE (2)EX600-ED3PWR IN7/8 5 1 0 V() 2 0 V() 3 FE 4 24 V() 5 24 V() (3)EX600-ED4PWR INM12 4 A code PWR OUTM12 5 A code 1 24 V() 1 24 V() 2 24 V() 2 24 V() 3 0 V() 3 0 V() 4 0 V() 4 0 V() 5 (4)EX600-ED5PWR INM12 4 A code PWR OUTM12 5 A code 1 24 V() 1 24 V() 2 0 V() 2 0 V() 3 24 V() 3 24 V() 4 0 V() 4 0 V() 5 -29No.EX-OMN0027CN-D 2 SI IP67 -30No.EX-OMN0027CN-D
Seal 7 Non-asbestos Seal 42047#1 (1 pc.) 8 Note) Consult with SMC when replacing parts since special tools are required for replacement. 17 Series HAW Dimensions HAW2/7 E F 2 x V Rc 2 x Y Rc Air outlet Air inlet Cooling water outlet Q 87 G K J H Cooling water inlet S L T 2 x 2 x U D W Rc N (M) Drain B C A HAW22 to 110 Air outlet Air inlet F E HAW110-30 P 2 x Y Rc 2 x V Screw-in (Z) (L) (ZA
JMHZ2-16D-X7400B-DTP-(N/P) . 12 3-5-2. JMHZ2-16D-X7400B-HC10DT-(N/P) . 13 3-5-3. JMHZ2-16D-X7400B-HC10-(N/P) . 14 3-6. Connector and pin layout . 15 3-6-1. JMHZ2-16D-X7400B-DTP-(N/P) . 15 3-6-2. JMHZ2-16D-X7400B-(HC10DT/HC10)-(N/P) . 16 3-7. Center of gravity . 17 4Product Specifications . 18 4-1. Air gripper . 18 4-2. 3-port solenoid valve . 19 4-3.
Refer to the table for each pressure specification (page 80) Display/set pressure range Display/min. setting unit Power supply voltage 12 to 24 VDC (10%), and ripple (p-p) 10% at max. Electric spec.
P 2 Specifications(NCRAl).P 3 Torque DiagramMeight CharvRotation Range. P 4 Shaft Load/Operational Instructions (NCRAI ) . P 5 Construction/ParlsList.-.P 6 Single Rod End/Dimensaons . .P 7 Double Rod End/Dimensions.-...P 8
Series:NCRAI How To Order Adluatable cuahlon C Both end cushion Not available on NCRA1BW30 Fotation
Upper and lower setting limit of user setting Analogue output Settable range during measurement range communication error or idling (Range) (Lwr_Lmt) (Upr_Lmt) (Fault_MA) (Idle_MA) 0..10 V 0.00 to +10.45 V +0.05 to +10.50 V 0.00 to +10.50 V 0..5 V 0.00 to + 5.22 V +0.03 to +5.25 V 0.00 to +5.25 V 1..5 V +0.75 to +5.22 V +0.78 to +5.25 V +0.75 to +5.25 V 0..20 mA 0.00 to +20.90 mA +0.10 to
V 5 to 1050 0..5 V 0.00 to +5.22 V 0 to 522 +0.03 to +5.25 V 3 to 525 1..5 V +0.75 to +5.22 V 75 to 522 +0.78 to +5.25 V 78 to 525 0..20 mA 0.00 to +20.90 mA 0 to 2090 +0.10 to +21.00 mA 10 to 2100 4..20 mA +3.00 to +20.90 mA 300 to 2090 +3.10 to +21.00 mA 310 to 2100 41 EX## OMS1015-A 7.
Compact Pressure Switch Specifications (For further information, refer to Best Pneumatics No. 8) IS10-01 Model 0.1 to 0.4 MPa Set pressure range (OFF) 0.08 MPa Hysteresis 1a Contact point construction 2 VA AC, 2 W DC Max. contact point capacity 12 V 48 V 100 V Voltage (AC, DC) 24 V 50 mA 40 mA 20 mA Max. current 50 mA Symbol 2 1 AMR4000 AMR3000 L AMR5100 686 Regulator with Mist Separator
HRX-OM-S004-N Operation Manual InstallationOperation Original Instructions Thermo chiller HRS100-A-20HRS150-A-20HRS100-A-40HRS150-A-40HRS100-A-46HRS150-A-46HRS100-W-20HRS150-W-20HRS100-W-40HRS150-W-40HRS100-W-46HRS150-W-46Keep this manual available whenever necessary 2023 SMC CORPORATION All Rights Reserved To the users Thank you for purchasing SMCs Thermo chiller (hereinafter referred to
Applicable bore (mm) A D L MM N R W B C H d Applicable bore (mm) Part no.
Applicable bore (mm) A D L MM N R W B C H d Applicable bore (mm) Part no.
Compact size (Width: 18 mm) Low power consumption: 1.8 W DC Fluid Air 0.15 to 0.7 0.1 to 0.7 0.15 to 0.7 10 to 50C (No freezing.
0 q CONTROLLER PRESSURE OUT w Position Detection Switch Flow Sensor Pressure Control Pressure Sensor e w r RUN 4 3 2 1 CH kPa 4 3 2 1 SW t e y D-IN RUN UP SET P-ON DOWN STOP READ r u i o t y u i o !
V Ps + 0.1 293 S = 12.1 log10 () (6) t P + 0.1 T S : Effective area [mm2] V : Air tank capacity [dm3] t : Discharging time [s] Ps : Pressure inside air tank before discharging [MPa] P : Residual pressure inside air tank after discharging [MPa] T : Temperature inside air tank before discharging [K] Power supply Pressure switch Thermometer Pressure control equipment Control circuit Solenoid
Connector pin numbers -18No.PS-OMS0007-H Internal circuit and wiring examples Z/ISE20(F)---Output specification -N NPN open collector 1 output Max. 28 V, 80 mA Residual voltage: 1 V or less -P PNP open collector 1 output Max. 80 mA Residual voltage: 1 V or less -19No.PS-OMS0007-H Outline of Settings [Measurement mode] Power is supplied.
Cable color Tarminal no. 1 1.5m U 1 Red 1 V 2 White 2 3 3m W 3 Black 3 5 5m Shield signal Tarminal no.
Fittings & Tubing Air Cylinders Rotary Actuators Bracket (Option) Bracket (Option) R R V Q V Q IN OUT B C IN OUT Clearance for maintenance G B C 2 x P (Port size) 2 x P (Port size) Hexagon width across flats 14 1/8 Drain Hexagon width across flats 17 1/4 E A Clearance for maintenance G Drain A AF50/60-A 1021J D M U S N T Bracket (Option) R V Q C B IN OUT 2 x P (Port size) Hexagon width across
IDX-OM-W019-C PRODUCT NAME Refrigerated Air Dryer MODEL / Series IDFB3E-11 -A,S IDFB4E-11 -A,R,T,S,V IDFB6E-11 -A,K,R,T,S,V IDFB8E-11 -A,K,R,T,S,V IDFB11E-11 -A,K,R,T,S,V IDFB15E-11 -K,R,T,S,V This manual is intended to explain the installation and operation of the product.