For details, refer to the IDK series in the Best Pneumatics No.6. 705 MHY2 Series Construction Closed condition 10 16 20, 25 r o !8 e w !7 t !5 r o !8 e !6 w @0 !7 t !5 r o !8 e !6 w @0 !7 t !5 !0 u !2 i q !1 !4 y !9 !0 u !2 i q !1 !4 y !9 !0 u !3 !2 i q !1 !4 y !9 Open condition Component Parts Note No.
8 @0 @2 @1 @7 RLQ @3 r MLU o #5 !6 $3 $4 MLGP Component Parts Component Parts Material No.
Refer to p.0-26 and 0-27 for Safety Instructions and common precautions on the products mentioned in this catalog and refer to p.1.0-1 and 1.0-2 for precautions on every series. Selection Piping Warning Warning Use auto drain under the following conditions. Use drain piping of auto drain under following conditions. Othrwise, it may cause malfunction.
hole F Applicable screw M5 hexagon socket head cap screw M6 hexagon socket head cap screw M8 hexagon socket head cap screw Model AMP220 AMP320 AMP420 E OUT Maintenance space (mm) C B Bracket related dimensions Element service indicator related dimensions Port size (nominal size B) Model A D E I 66 80 90 J K L M N O P Q R S F 80 120 180 G 123 169 237 H AMP220 AMP320 AMP420 76 90 106 76 90
Leakage voltage Caution Take note that the leakage voltage will increase when a resistor is used in parallel with a switching element or when a C-R circuit (surge voltage suppressor) is used for protecting a switching device because of the leakage voltage passing through the C-R circuit. The suppressor residual leakage voltage should be as 3% or less of the rated voltage. 3.
Cylinder Port: NPT, Arm Opening Angle: 120°, Arm Position: R (Right Side), Switch Type: P (P & F PNP), R Arm Mtg Position: A (Mounting Position A), R Arm Style: A011 (25mm Offset Machined ref NAAMS ACA217M)
Cylinder Port: NPT, Arm Opening Angle: 90°, Arm Position: R (Right Side), Switch Type: P (P & F), R Arm Mtg Position: A (Mounting Position A), R Arm Style: A001 (Straight Plain ref NAAMS ACA100M)
Voltage drops at the value of r x I. PS1000, PS1100 Caution 1 to 5 [V] Current I Lead wire resistance r The load current range for a PS1000 and PS1100 is between 5 [mA] to 40 [mA]. If 40 [mA] is exceeded the output transistor could be damaged. Besides, do not connect a PLC, which can detect 1 [mA], since there is a leak current of 1 [mA] in OFF state.
Pressure Switch Specifications ZSE30 (Vacuum/Low pressure) 100.0 to 100.0 kPa 101.0 to 101.0 kPa 500 kPa 0.2 kPa ISE30 (Positive pressure) 0.000 to 1.000 MPa 0.100 to 1.000 MPa 1.5 MPa 0.001 MPa Rated pressure range Regulating pressure range Proof pressure Min. regulating unit Fluid Power supply voltage Current consumption Switch output Air, Inert gas, Non-flammable gas 12 to 24 VDC, Ripple (p-p
r Stainless steel, Brass FKM/EPDM 32A to 50A 32A to 50A Valve spring Valve spring Stainless steel Stainless steel, Copper Stainless steel, NBR Stainless steel Class B molded Stainless steel Stainless steel, Silver FKM/EPDM, PTFE t t 10A to 25A 32A to 50A Stainless steel, Silver Stainless steel, Copper, NBR Polyacetal PTFE Class B molded 15A to 25A Core assembly y Stainless steel, FKM
Cylinder Port: TF (G), Arm Opening Angle: 90°, Arm Position: R (Right Side), Switch Type: P (P & F PNP), R Arm Mtg Position: A (Mounting Position A), R Arm Style: A012 (25mm Offset Machined ref NAAMS ACA218M)
Cylinder Port: TF (G), Arm Opening Angle: 90°, Arm Position: D (Both Sides), Switch Type: P (P & F), R Arm Mtg Position: X [w/o Arm on Right Side (D Arm Position Type Only)], R Arm Style: XXXX [w/o Arm on Right Side (D Arm Position Type Only)], L Arm Mtg Position: A (Mounting Position A), L Arm Style: A024 (25mm Offset Machined ref NAAMS ACA024M), Painted Arm: P (Paint)
Cylinder Port: TF (G), Arm Opening Angle: 90°, Arm Position: D (Both Sides), Switch Type: P (P & F), R Arm Mtg Position: C (Mounting Position C), R Arm Style: A048 (120mm Offset Machined ref NAAMS ACA048M), L Arm Mtg Position: X [w/o Arm on Left Side (D Arm Position Type Only)], L Arm Style: XXXX [w/o Arm on Right Side (D Arm Position Type Only)], Painted Arm: P (Paint)
Cylinder Port: TF (G), Arm Opening Angle: 90°, Arm Position: D (Both Sides), Switch Type: P (P & F PNP), R Arm Mtg Position: A (Mounting Position A), R Arm Style: A024 (25mm Offset Machined ref NAAMS ACA248M), L Arm Mtg Position: X [w/o Arm on Left Side (D Arm Position Type Only)], L Arm Style: XXXX [w/o Arm on Left Side (D Arm Position Type Only)], Painted Arm: P (Paint)
70 N 11 18 18.5 20 26 ZZ 103 132 137 156 182 NA 17 24 30 36 46 R 28 34 40 50 S 83 106 111 124 150 W 35 50 50 50 60 X 19 25 30 40 40 Model 12-CY3B15 12-CY3B20 12-CY3B25 12-CY3B32 12-CY3B40 P (Piping port) Model Mounting nuts (2 pcs.) are shipped together.
Check valve Pressure switch (for vacuum) Suction filter Variable throttle # P Variable throttle Suction filter 3 port valve is used to generate and stop the vacuum (vacuum release is performed simultaneously). Variable throttle is installed for break flow adjustment.
(Example) 40D-A3C-4, 63D-A3C-6, 100D-A3C-10 50D-A3C-5, 80D-A3C-8 1.08 0.32 0.38 0.38 0.73 Double knuckle Accessory bracket 0.19 0.05 0.05 0.05 0.14 Knuckle pin 10-12-49 7 Series CE2 Dimensions: 40 to 100 RC 1/4 Pressurized locking port RC P Rod side cylinder port RC P Head side cylinder port Basic style RC 1/4 Unlocking port Unlocked when pressurized 7 (6 core twisted pair shielded wire)