SMC Corporation of America
Elite Part Number Search
Search Results "VV5K3-41-06-M5"

For manifold type 31, S31, 32, S32 5 port (With gasket and screws) D: Push-turn locking slotted type M5: With M5 port sub-plate For sub-plate, manifold type 41, S41, 46, S46 Electrical entry 24, 12 VDC 6, 5, 3 VDC 24, 12, 6, 5, 3 VDC 100, 110, 200, 220 VAC E: Push-turn locking lever type Grommet L plug connector M plug connector M8 connector WO: Without connector cable M: With lead wire (

(For type 20 manifold) M 1 SYJ3 2 5 M M3 10 Body ported M 1 SYJ3 4 5 M 10 Base mounted CE-compliant Clean series Port size Nil Q CE-compliant 3 port Nil: Without sub-plate M5: M5 port With sub-plate Note) CE-compliant: For DC only.

: With M5 port sub-plate Nil Standard With power saving circuit T For sub-plate, type 41, S41, 46, S46 manifold (24, 12 VDC only) Power saving circuit is not available for W type.

3 Port Air Operated Valve Series SYJA300 How to Order SA Bracket VA With bracket F Nil Without bracket SYJA3 2 1 M3 Body ported SA VA SYJA3 4 1 Base mounted VM VR Port size Type of actuation Nil Without sub-plate VH Normally open Normally closed 2 1 M5 port with sub-plate M5 VHS How to Order Manifold Base Same manifolds as Series SYJ300 are prepared. SS3YJA3 Fill the same as SS3YJ3.

External pilot type is not available. 1 SYJ3 2 5 M M3 Body ported SYJ3 4 5 M 1 Base mounted Port size 3 port Nil: Without sub-plate M5: M5 port With sub-plate Coil specifications Nil Standard With power saving circuit (24, 12 VDC only) T Power saving circuit is not available in the case of W type.

IP40 050 -1070 () 3585% RH() AC1000 V50/60Hz1 5 M(DC500 V) 2%F.S.(25 ) 3 2.7 3 m / 2 0.15 mm 0.8 mm CERoHS M5 R06 R07 M50.8 6 1/4 inch ONBR SUS304 PBT (3 m) 41 g 38 g 7 g 3.8 g -12No.PS-OME0003CN-F [V] A B C 0-101kPa 0 -101 kPa 10.1 kPa -101101kPa -100 kPa 101 kPa 0101kPa 0 101 kPa -10.1 kPa -01MPa 0 1 MPa -0.1 MPa -13No.PS-OME0003CN-F PSE53-M5 PSE53R06 R07 (D) PSE53-

) shows the nominal filtration accuracy. 5 Valve Rc1/2 Cable Specifications Power Supply Cable and Earth Leakage Breaker (Recommended) Recommended crimped terminal Cable specifications Earth leakage breaker Breaker size [A] Sensitivity current [mA] Terminal block screw diameter Model Power supply voltage specifications HRL100-Am-20 3-phase 200 VAC (50 Hz) 3-phase 200 to 230 VAC (60 Hz) M5

Model Elbow type Straight type In-line type 12-REA25 10-AS2001F-06-X214 10-AS2201F-01-06-X214 10-AS2301F-01-06-X214 12-REA32 10-AS2001F-06-X214 10-AS2201F-02-06-X214 10-AS2301F-02-06-X214 6. Do not use the cylinder with its body fixed. Be sure to secure both head covers (or end covers in case of CY1R) before using the cylinder.

BA -08 BA -10 BA -32 BA -02 BA -01 CX D-G5NBL 35 40 45 45 45 40 50 45 D-G5/K5 D-B7/B8 BM1 -01 BM1 -02 BM1 -32 BM1 -04 BM1 -05 BM1 -06 Since this is a guideline including hysteresis, not meant to be guaranteed.

JIS Symbol How to Order 1 F 06 3 200 AS Flow Direction Symbols on Body JIS Symbol Body size Panel mount type Symbol M5 standard 1/8 standard 1/4 standard 3/8 standard 1/2 standard 100 200 205 300 400 Applicable tubing O.D.

JIS Symbol How to Order 1 F 06 3 200 AS Flow Direction Symbols on Body JIS Symbol Body size Panel mount type Symbol M5 standard 1/8 standard 1/4 standard 3/8 standard 1/2 standard 100 200 205 300 400 Applicable tubing O.D.

How to Order 1 F 06 3 200 AS Flow Direction Symbols on Body Hexagon lock nut Round lock nut J Nil Lock nut option Body size Indication symbol Panel mount type Symbol M5 standard 1/8 standard 1/4 standard 3/8 standard 1/2 standard 100 200 205 300 400 Made to Order Refer to page 622 for details. Applicable tubing O.D.

M5 standard 1/8 standard 1/4 standard 3/8 standard 1/2 standard 100 200 205 300 400 Applicable tubing O.D.

How to Order Integrated Display Type H PF2A7 Flow rate range Unit specification High flow rate type Wiring specification 150 to 3000l/min 300 to 6000l/min 600 to 12000l/min 03 06 12 Nil M With unit switching function Fixed SI unit Note) Port specification Nil N 3m lead wire with connector Without lead wire Nil N F Rc NPT G Note) Fixed units: Real-time flow rate: l/min Accumulated flow: l,

Pin description 1 DC (+) 2 Analog output Accumulated pulse output wiring examples 3 DC () 4 OUT1 4-I thread with depth J 40 Max. 30V 80 mA or less OUT1 Black Load H 0V Blue 50 msec PF2A7H--28 29(-M) A B C D E F G H I J Model Brown PF2A703H PF2A706H PF2A712H 55 160 40 92 67 55 Rc 1, NPT 1, G 1 36 M5 x 0.8 8 OUT1 80 mA Load Black 65 180 45 104 79 65 Rc 11/2, NPT 11/2, G 11/2 Rc 2, NPT 2, G

Length 38 62 72 90 104 114 135 140 78 111 119 147 179 191 236 277 Flat washer Hexagon nut AS1002F-02 AS1002F-23 AS1002F-04 AS1002F-06 AS2002F-04 AS2002F-06 AS2052F-06 AS2052F-08 AS3002F-06 AS3002F-08 AS3002F-10 AS3002F-12 AS4002F-10 AS4002F-12 AS-31B AS-32B AS-33B AS-34B AS-35B AS-36B AS-37B AS-38B AS-41B AS-42B AS-43B AS-44B AS-45B AS-46B AS-47B AS-48B AS1002F-01 AS1002F-03 AS1002F

No.ZL3-OM00601-B 1.How to Order ZL3 M 06 1 K1 5 LO Z 1 E A M G 1 Without valve ZL3 M 06 1 K1 5 LO Z 1 E A M G 1 With valve Pressure switch ZL3 M 06 1 K1 5 LO Z 1 V A M W 1 with energy saving function 1) 2) 3) 4) 5) 6) 7) 8) 9) 10) 11) 12) 13) 14) 1) Max. suction flow 2) Standard supply pressure 4) Exhaust specifications 3 300L/min(ANR) M 0.35MPa Nil Exhaust through silencer H 0.50MPa

How to Order Integrated Display Type H PF2A7 Flow rate range Unit specification High flow rate type Wiring specification 150 to 3000l/min 300 to 6000l/min 600 to 12000l/min 03 06 12 Nil M With unit switching function Fixed SI unit Note) Port specification Nil N 3m lead wire with connector Without lead wire Nil N F Rc NPT G Note) Fixed units: Real-time flow rate: l/min Accumulated flow: l,

Tightening with excessive force may damage the product. 18 Multistage Ejector Max. suction flow rate: 300 L/min (ANR) Max. suction flow rate: 600 L/min (ANR) ZL3/ZL6 Series Only for the models with a valve or pressure switch RoHS How to Order ZL 3 M 06 06 06 Without valve ZL 3 M K1 5 LO Z E A M G With valve ZL 3 M K1 5 LO Z V A M Pressure switch with energy saving function q w e r u !

Screw tightening torque VO307K: 1.35 to 1.45 Nm V11 : 0.14 to 0.17 Nm Parts for manifold 02 03 04 02 03 04 04 06 10 01 02 10 12 01 02 14 20 Description VEX312VEX322VEX332VEX342VEX350VEX370VEX390Bracket (with bolt and washer) VEX1-18-1A VEX5-32A VEX7-32A VEX9-32A Foot bracket (with bolt and washer) VEX1-18-2A VEX3-32-2A Silencer for pilot exhaust port (PE) AN120-M5 AN103-01 AN210-02 Note 1