PLC H.T. ) Enable 1 (SC_MonSs) Disable -10..10 V -5..5 V -20..20 mA 0..10 V 2 (Range) -10..10 V 0..5 V 1..5 V 0..20 mA 4..20 mA Offset binary PLC 3 (D_Format) Sign & Magnitude 2S Complement None 2 2AVG 2 4 (Filter) 4AVG 4 8AVG 8 Enable 0.5 5 (Over_Rng) Disable Enable 0.5 6 (Undr_Rng) Disable Enable 1 (Upr_Lmt) 7 Disable Enable 1 (Lwr_Lmt) 8 Disable
Symbol 100 200 500 50 10 Rc NPT G 01 02 03 04 1/8 1/4 3/8 1/2 PFA510, 550 PFA511, 521 PFA551 Specifications PFA511 PFA521 PFA551 PFA510 PFA550 Model Measured fluid Dry air, N2 Detection type Heater type 20 to 200l/min 50 to 500l/min 10 to 100l/min 1 to 10l/min 5 to 50l/min Flow rate measurement range Operating pressure range 0 to 0.5MPa Withstand pressure 1.0MPa 3kPa (at 50l/min) 3kPa
to 50C 10 to 50C Ambient and fluid temp.
Orifice size Class 3 Class 2 Orifice size (mm) 2 3 4 5 7 10 Class 4 Symbol 2 3 4 5 7 10 Electrical entry G Grommet C Conduit Refer to the below table for orifice and port size combinations.
Please see the PLC manufacturers documentation for detailed instructions on the setup and use of your PLC. 10 - IN20267 Terminology 4. Terms Meaning 100 100BASE-TX Standard LAN transmission line with communication speed of 100 Mbps.
Specications Model PSE570 PSE573 PSE574 PSE575 PSE576 PSE577 Fluid Applicable uid Gas or liquid that will not corrode the materials of parts in contact with uid Pressure Rated pressure range 0 to 1 MPa 100 to 100 kPa 0 to 500 kPa 0 to 2 MPa 0 to 5 MPa 0 to 10 MPa Proof pressure 3.0 MPa 600 kPa 1.5 MPa 5.0 MPa 12.5 MPa 30 MPa Electrical Power supply voltage 12 to 24 VDC 10% with 10% voltage
Model PP SS VV OO Gasket QQ RR TT UU ML1C25 ML1C32 ML1C40 C11.2 10 14 37 24 8 27 20 8 16.5 C11.2 18 46 30 12 32 22 8 17 23.5 12.5 10 C14 53 40 34 26 Model A B C D E F G H I J K L M N P Q S T O R U W Z V Y ML1C25 ML1C32 ML1C40 274 260 137 140 88 108 87 85.5 60 74 97 100 42.5 26 34 206 28 24 5.6 9 5.5 8.5 9.5 M5 X 0.8 M6 X 1 11 322 306 161 160 108 131 101 99.5 64 92 118 120 53.5 28 40 242 36.5
Valve type 4.12-10 Valve Unit Series CCVS/CCVL Applicable converter Solenoid valve function plate Solenoid valve specifications of combined valve (stop valve/skip valve) Valve unit Small flow Large flow Nominal size (mm) 63, 100 100, 160 N.C.* N.O.** Solenoid valve style Stop valve Skip valve Valve type Solenoid valve model VO301-00 ** 0.3 to 1.0MPa OP CL 100V, 200V AC, 24V DC CL OP External
Metric sizes 6 8 10 12 Flow rate l/min (ANR) Controlled 100 180 230 260 390 460 660 790 920 1580 1710 (free) flow Effective area mm 1.5 2.7 3.5 4 6 7 10 12 14 24 26 Note) Flow rate values are at a pressure of 0.5MPa, and temperature of 20C.
0.4 MPa setting (Ex.)10-ARP30-02BG 0.005 to 0.4 MPa Set pressure range Note1) 0.2 MPa setting (Ex.)10-ARP30-02BG-1 0.005 to 0.2 MPa 0.6 MPa setting (Ex.)10-ARP30-02BG-3 0.008 to 0.6 MPa Within 0.2% F.S.
0.4 MPa setting (Ex.)10-ARP30-02BG 0.005 to 0.4 MPa Set pressure range Note1) 0.2 MPa setting (Ex.)10-ARP30-02BG-1 0.005 to 0.2 MPa 0.6 MPa setting (Ex.)10-ARP30-02BG-3 0.008 to 0.6 MPa Within 0.2% F.S.
This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYL, TIE ROD, N/LUBE, SCRAPER, ACTUATOR, CA1/CA2 TIE-ROD CYLINDER, PC, 63MM CA1 OTHERS (COMBO), 7.56106 lb
Double acting, single rod, standard type, Bore sizes (mm): 40, 50, 63, 80, 100, Standard strokes (mm): 25 to 700, Maximum operating pressure: 1.0MPa, Auto switch capable, CYL, TIE ROD/SPL PORT POSITION, ACTUATOR, CA1/CA2 TIE-ROD CYLINDER, PC, 63MM CA1 OTHERS (COMBO), 7.56106 lb
Min. 207 Panel 54 72.5 10 69.5 2 R1/8 74 40 7 30 OUT OUT IN 2 x M6 depth 10 2 x Rc1/4 Pressure gauge port Rc1/8 78 70 A 160
Cassette Case Seal q O-ring Pressure drop (kPa) 10 IN ZFC100-04 Cover B Element Cover A 1 ZFC100-06 ZFC200-06 Replacement Parts ZFC200-08 0.1 1 10 100 Description Part no.
48.2 50.0 factor 1.00 1.02 1.05 1.07 1.10 1.12 1.15 1.18 * The DewPoint refers to an ambient temperature of +100F with inlet air at 100 psig and +100 F.
L L 2 . 3 . 6 4 . 5 . 6 . 2 2-3. 1 2 Nm mm 16 5 20 M30.5 0.59 6 25 6 8 32 40 M40.7 1.4 8 10 50 63 M50.8 2.8 10 80 M61 4.8 12 100 M81.25 12 16 125 M101.5 24 20 3 P9P11 7 Nm mm MHSH(J)3-32DA,B M30.5 0.6 6 40DA,B M50.8 2.8 10 50DA,B M61 4.8 12 63DA,B M81.25 12 16 80DA,B M101.5 24 20 A J/ / 8 MHS2 Nm mm MHS2-16D M40.7 2.1 8 20D M40.7 2.1 8 25D M40.7 2.1 8 32D M50.8 4.3 10 40D M61 7.3
Allen-Bradley PLC 1747-L524, list price: $770 as of 10/01 2. Allen-Bradley I/O card 1740OB, list prices: $280 as of 10/01 3. Allen-Bradley Scanner module 1747 SN, list price: $995 as of 10/01 4. Wiring costs are estimated at $10/point and $100/node for SI system. Your costs may vary. 5.
[L/min (ANR)] 200 06 200 04 06 08 50 500 04 100 100 0 0 0 0 5 10 5 10 5 10 5 10 Number of needle rotations Number of needle rotations Number of needle rotations Number of needle rotations Note) The numbers above the flow rate characteristic curves in the charts show the tubing diameter as defined by the product number.
type allows element replacement ZFB30 8, 10, 3/8" 75 Easily replaced filter element ZFB40 1/2" 100 ZFC 10 4, 5/32" ZFA ZFA IN/OUT straight piping ZFC5 In-line type 20 Easy installation and removal with One-touch fittings ZFB ZFB 6, 1/4" 30 ZFC ZFC 5 P.281 Light and compact molded resin parts 8, 5/16" 70 ZFC7 10, 3/8" 80 Easily replaced filter element 12 100 Note) Flow rate when initial