Install a suitable filter (strainer) immediately upstream from the valve. As a general rule, use 80 to 100 mesh. Caution 1.
Contact P/A regarding other voltages.
FKM Needle Needle guide Stainless steel 316 Stainless steel 316 Body B Stainless steel 316 3 Series ASG Dimensions ASG22F-M5 H L4 (Width across flats) Applicable tubing O.D. d A L6 D L5 M L3 L1 T L2 ASG32F-01 ASG42F-02 ASG52F-03 ASG62F-04 H (Width across flats) L4 Applicable tubing O.D. d L6 A D L5 M T L1 L3 L2 Max.
-10AS G46-2-02 G36-2-01 G46-2-02 G46-2-02 G46-2-02 0.2MPa Note 3) GC3-2AS GC3-2AS GC3-2AS GC3-2AS GC3-2AS Note 1) Assembly includes a bracket and set nuts.
OUT 1 Thread type Rc NPT NPTF G Nil N T F IN Voltage 1 2 3 4 5 6 36 100VAC 200VAC 110VAC 220VAC 24VDC 12VDC 230VAC Port size Class 3 Class 2 Port size 1/8 (6A) 1/4 (8A) 3/8 (10A) 1/2 (15A) 3/4 (20A) Symbol 01 02 03 04 06 Class 4 Class B with AC has a built-in rectifying circuit. Class H is AC only. Without rectifying circuit. Contact P/A regarding other voltages.
For the IR400-02/03/04□□: IR3000-02/03/04□□-A
For the IR401-02/03/04□□: IR3010-02/03/04□□-A
For the IR402-02/03/04□□: IR3020-02/03/04□□-A
For the IR412-02/03/04□□: IR3120-02/03/04□□ (IR-A series air operated regulators will be available at a later date.)
Note) Select option “H” when panel mounting the product.
Add a "" in front of the part numbers for solenoid valves, etc., to be mounted. 2 3 4 Class 2 Class 3 Class 4 Enter together in order, counting from station 1 on the D side. OUT port size Material Symbol 01 02 Port size 1/8 (6A) 1/4 (8A) Stations D side U side 1 2 3 4 5 n Body material Brass Symbol D H Seal material FKM FKM 02 : 10 2 stations : 10 stations All IN ports are 3/8.
E 3 Auto-drain Pressure gauge mounting Port size 02 03 04 06 10 ARJ MR unit 1 None With auto drain 0 Flow direction: Right to left Nil Flow direction: Left to right Applicable model 1/4 3/8 1/2 3/4 1 Nil E2 E3 E4 E6 E10 R 3 4 5 6 AMR3 00-02 to 03 AMR4 00-02 to 04 AMR5 00-04 to 06 AMR6 00-10 AR425 to 935 Adapter assembly port size (2 pcs.)
Working principle A + A A Series CXS 6, 10, 15, 20, 25, 32 Reverse mounting Piston seal A A A R H R H 1. When the piston is retracting, air is exhausted through both A and A until piston seal H passes air passage A. 2. After piston seal H has passed air passage A, air is exhausted only through A.
Operate the piston within a range such that collision damage will not occur at the end of the stroke. When a cylinder is used in a clamping mechanism, there is a danger of work pieces dropping if there is a decrease in clamping force due to a drop in circuit pressure caused by a power outage, etc.
This can cause a loss of holding force and malfunction. AS2201F-01-06-X214 AS2301F-01-06-X214 RS H A AS2201F-01-06-X214 AS2301F-01-06-X214 AS2201F-02-06-X214 AS2301F-02-06-X214 RZQ 3. When disassembling to replace the seals and wear ring, refer to the separate disassembly instructions. AS3201F-02-08-X214 AS3301F-02-08-X214 AS3201F-02-08-X214 AS3301F-02-08-X214 MI W S 4.
This can cause a loss of holding force and malfunction. AS2201F-01-06-X214 AS2301F-01-06-X214 RS H A AS2201F-01-06-X214 AS2301F-01-06-X214 AS2201F-02-06-X214 AS2301F-02-06-X214 RZQ 3. When disassembling to replace the seals and wear ring, refer to the separate disassembly instructions. AS3201F-02-08-X214 AS3301F-02-08-X214 AS3201F-02-08-X214 AS3301F-02-08-X214 MI W S 4.
For a facility having a large installation area (that can vent the air naturally): Make an air outlet on a wall at a high level and air inlet on a wall at a low level, to allow for adequate airflow. 2. For a facility having a small installation area (that can not vent the air naturally): Make a forced air exhaust vent on a wall at a high level and an air inlet on a wall at a low level.
A B A B A Void A Void A B A B A B A A A B Double Double Double Double Double SY Sl unit Sl unit Single Single Single Single Single SYJ Stations Stations 1 2 3 4 5 1 2 3 4 5 Single/Double mixed wiring (Option) Double wiring (Standard) SX SC applicable to SYSBUS Wire System (OMRON) SD applicable to Satellite I/O Link System (Sharp) VK VZ ADDRESS NO. STATION NO.
2 A 2 A 24 VDC 0.63 A 1 A 1 A Temperature rise*5 25C 25C 25C 1 Leakage: The value at a differential pressure of 0.01 MPa or higher and an ambient temperature of 20C 2 This product has an IP67 enclosure, but if water enters the product, it may result in malfunction or breakage.
For a facility having a large installation area (that can vent the air naturally): Make an air outlet on a wall at a high level and air inlet on a wall at a low level, to allow for adequate airflow. 2. For a facility having a small installation area (that can not vent the air naturally): Make a forced air exhaust vent on a wall at a high level and an air inlet on a wall at a low level.
For a facility having a large installation area (that can vent the air naturally): Make an air outlet on a wall at a high level and air inlet on a wall at a low level, to allow for adequate airflow. 2. For a facility having a small installation area (that can not vent the air naturally): Make a forced air exhaust vent on a wall at a high level and an air inlet on a wall at a low level.
Since a large quantity of liquid will be pumped out, use a suitable throttle in the discharge port if problems occur. Note 3) With a low number of operating cycles, even a valve with a small Cv factor can be operated.
A Station 1 1 SOL. A Station 2 14 SOL. A Station 3 2 1 SOL. A Station 4 14 15 2 SOL. A 15 3 3 4 5 6 7 Station 5 16 17 18 19 20 SOL. B 16 SOL. A 4 Station 6 SOL. B 17 SOL.