B D Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Parallel electrical entry B A A D Reed Switch D-A90(V), D-A93(V), D-A96(V) Reed Switch D-A90(V), D-A93(V), D-A96(V) Set screw (included to auto switch) (mm) Stroke (mm) 20 45 25 51 31 Stroke (mm) 10 34.5 35.5
Auto Switch Proper Mounting Position (Detection at Stroke End) Solid state auto switch D-M9 Reed auto switch D-A93 C B A Lead wire, in-line entry Values in the table below are used as a reference when mounting the auto switches for stroke end detection. For actually setting the auto switches, adjust them after confirming their operation.
Please consult with SMC regarding water resistant type with the above model numbers. 2 1 m type lead wire is only applicable to D-A93. Solid state auto switches marked with are produced upon receipt of order.
Lead wire length (m) Load voltage Auto switch model Electrical entry direction Wiring (Output) Special function Electrical entry Indicator light Style 0.5 (Nil) 3 (L) Applicable load AC DC 12V Horizontal 100V 24V Reed switch 2-wire Relay, PLC Grommet Yes A93 12V 3-wire (NPN) M9N 24V Solid state switch Relay, PLC Grommet Yes 12V 2-wire M9B Lead wire symbol 0.5mNil (Example) A93
Applicable models: D-A73, A73H, D-A93, A93V 2) Note however, that in the case of 2 color indicator type auto switches (D-A79W), if the wiring is reversed, the the switch will be in a normally ON condition.
However, if there is any problem, use a 3 wire DC style. 3.8-11 Series CXT Auto Switch Mounting Position and Mounting Height Reed switch Solid state switch A B W D-F9NW D-F9PW D-F9BW D-A90 D-A93 D-A96 D-F9N D-F9P D-F9B D-F9BAL 12 A B W 16, 20, 25 W A B 32, 40 (mm) D-A90 D-A93 D-A96 D-F9NW D-F9PW D-F9BW D-F9N D-F9P D-F9B Auto switch model D-F9BAL Symbol A B W A B W A B W Standard stroke 12
Applicable models: D-A73, A73H, A73C, Z73, D-A93
Note 3) ( ) in column W is the dimensions of D-A93.
Internal voltage drop Indicator light (lights when ON) Applications AC DC 24V or less AC DC 48V or less AC DC100V or less 24VDC 100VAC 50mA 40mA 20mA 5 to 40mA 5 to 20mA Relay, PLC, IC circuit D-A90 D-A90V None 0 Relay, PLC D-A93 D-A93V 2.6V or less D-A96 D-A96V 4 to 8VDC 20mA 0.8V or less IC circuit Lead wires D-A90, A93 : Oil resistant heavy duty vinyl cord 2.7 0.18mm x 2 wire (Brown
For 10, 15, 20 CE2 Lead wire length (m) Load voltage Indicator light Pre-wire connector Special function Type Electrical entry Wiring (Output) ML2B Applicable load AC DC Auto switch model 0.5 (Nil) 3 (L) 5 (Z) 3-wire C J G5-S Reed switch Solid state switch Reed switch Solid state switch A96 5 V IC circuit Yes Yes Grommet (NPN equivalent) 100 V 24 V 12 V A93 M9N M9P M9B F9NW F9PW F9BW 3-
Note 4) Figures in ( ) in the table W are D-A93.
The CRA1 rack & pinion rotary actuator offers very high torque-to-size and accurate positioning. Bore sizes are 30, 50, 63, 80 and 100mm. Units may be ordered auto-switch capable and with cushions. Dimensions range from 3" X 4" X 2" to a maximum of 8" X 9.65" X 4.41". Single shaft end or double shaft end models are available.Standard type rotary actuator, 3 mounting types available, Single
Cylinder (Tube) Inner Diameter(φ): 40, Stroke(mm): 180, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Air cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Port thread type: Rc, Auto Switches: M9B, Lead Wire Length
Cylinder (Tube) Inner Diameter(φ): 20, Stroke(mm): 180, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Air cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Port thread type: M5 × 0.8, Auto Switches: M9BW, Lead Wire
Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 180, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Rubber cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Port thread type: Rc, Auto Switches: M9BA, Lead Wire
Cylinder (Tube) Inner Diameter(φ): 32, Stroke(mm): 180, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Cushion: Rubber cushion, Operating Pressure(MPa): 0.05 to 1.0, Specification: Built-in magnet, Port thread type: Rc, Auto Switches: M9BA, Lead Wire
Specification: C (Metric Specifications), Magnet: D (Built-in), Mounting: B (Basic Type), Shaft Type: Y (Double Shaft w/Key), Type: U (Angle Adjustable), Size: 80, Rotating Angle: 180 (180°), Air Cushion: None, Actuation Type: 2 (2 Position Double), Voltage: 5 (24 VDC), Electrical Entry: DO (w/o Connector), Light/Surge Voltage Suppressor: w/o Light/Surge Voltage Suppressor, Manual Override
Specification: C (Metric Specifications), Magnet: D (Built-in), Mounting: B (Basic Type), Shaft Type: S (Single Shaft), Type: Standard, Size: 50, Rotating Angle: 180 (180°), Air Cushion: None, Actuation Type: 1 (2 Position Single), Voltage: 5 (24 VDC), Electrical Entry: D (DIN Terminal w/Connector, IP65 Compatible), Light/Surge Voltage Suppressor: w/o Light/Surge Voltage Suppressor, Manual