Rated Flow Range: 40 (5 to 40 L/min), Flow Adjustment Valve: None, Thread: N (NPT), Port Size: 06 (3/4), Output Specification: A (OUT1: NPN; OUT2: NPN), Temperature Sensor: None, Lead Wire: N (w/o Lead Wire w/M8 Connector), Unit Specification: J (Instantaneous Flow Rate: L/min; Accumulated Flow: L; Temp: °F)
Rated Flow Range: 10 to 100 L/min, Flow Adjustment Valve: None, Thread: NPT, Port Size: 3/4, Output Specification: OUT1: NPN; OUT2: NPN, Temperature Sensor: None, Lead Wire: w/o Lead Wire w/M8 Connector, Unit Specification: Instantaneous Flow Rate: L/min; Accumulated Flow: L; Temp: °F, Bracket: -, Calibration Certificate: -, Made to Order: -
Rated Flow Range: 2 to 16 L/min, Flow Adjustment Valve: None, Thread: NPT, Port Size: 1/2, Output Specification: OUT1: NPN; OUT2: NPN, Temperature Sensor: None, Lead Wire: w/o Lead Wire w/M8 Connector, Unit Specification: Instantaneous Flow Rate: L/min; Accumulated Flow: L; Temp: °F, Bracket: -, Calibration Certificate: -, Made to Order: -
Rated Flow Range: 5 to 40 L/min, Flow Adjustment Valve: None, Thread: NPT, Port Size: 1/2, Output Specification: OUT1: NPN; OUT2: NPN, Temperature Sensor: None, Lead Wire: w/o Lead Wire w/M8 Connector, Unit Specification: Instantaneous Flow Rate: L/min; Accumulated Flow: L; Temp: °F, Bracket: -, Calibration Certificate: -, Made to Order: -
Rated Flow Range: 5 to 40 L/min, Flow Adjustment Valve: None, Thread: NPT, Port Size: 3/4, Output Specification: OUT1: NPN; OUT2: NPN, Temperature Sensor: None, Lead Wire: w/o Lead Wire w/M8 Connector, Unit Specification: Instantaneous Flow Rate: L/min; Accumulated Flow: L; Temp: °F, Bracket: -, Calibration Certificate: -, Made to Order: -
Cooling Method: A (Air-cooled Refrigeration), Pipe Thread: N (NPT, w/Rc-NPT Conversion Fitting), Power Supply: 20 (3-phase 200 VAC, 50Hz; 3-phase 200 to 230 VAC, 60Hz), Option: J (w/Automatic Fluid Fill Function)
an external temperature sensor is displayed.
B 2 (EA)5 1 (P) 3(EB) M5: M5 x 0.8 3 position closed center 2(B) (A)4 Back pressure check valve 3 J: With switch A 4 Nil None (EA)5 1 (P) 3(EB) K Built-in 2 B 3 position exhaust center The built-in back pressure check valve type has an effective area approximately 20% smaller.
N o t e 3 ) F.P. and S. kits are provided with an exhaust on one side, while C kits are with an exhaust on both sides. K I TE L E C T R I C A L E N T R YC A B L E L E N G T H Courtesy of Steven Engineering, Inc. ! 230 Ryan Way, South San Francisco, CA 94080-6370 ! Main Office: (650) 588-9200 ! Outside Local Area: (800) 258-9200 !
An application which could have negative effects on people, property, or animals requiring special safety analysis. 4. Use in an interlock circuit, which requires the provision of double interlock for possible failure by using a mechanical protective function, and periodical checks to confirm proper operation. 1.
An application which could have negative effects on people, property, or animals requiring special safety analysis. 4. Use in an interlock circuit, which requires the provision of double interlock for possible failure by using a mechanical protective function, and periodical checks to confirm proper operation. 1. The product is provided for use in manufacturing industries.
Install an air dryer or after cooler on the upstream side of the pressure release 3 port valve because air containing excessive drainage may cause malfunction. SA VA SA Model VHS20 VHS30 Effective sectional area (mm2) (Cv) 5 (0.27) 5 (0.27) Caution VA 3. Do not apply negative pressure. It may result in malfunction. 1. Install an air filter of 5 mm filtration on the inlet side. 2.
Then, give an additional half rotation of screw. After that, incline the lever by 90 and confirm that the indicator light is not on and does not show either red or green.
For the external pilot valve, an R should be attached to the valve and the manifold part number. (See the below.)
ZP3P-20PTSF ZP3P-25PTSF ZP3P-35PTSF ZP3P-50PTSF p. 2 q Pad unit With Buffer p.6 e Buffer assembly Pad diameter Part no. 20 25 35 50 Dimensions ZPB2(J/K)10-B5 V V ZPB2(J/K)20-B5 V V ZPB3(J/K)10-B01 V V ZPB3(J/K)20-B01 V V p. 12 e Buffer assembly w T female thread adapter Pad diameter Part no. 20 25 35 50 Dimensions ZP3PA-T1-B5 V V ZP3PA-T2-B8 V V w T female thread adapter p. 11
Note 2) An auto switch magnet is not attached. In cases where an auto switch magnet is attached, please add -M9// at the end of the part number. (Not available for high temperature models) Note 3) Auto switch and solenoid valve are not attached.
Therefore, if an air compressor has a low air delivery, the pressure may not be sufficient. Auto Drain Caution The auto drain may not function properly, depending on the quality of compressed air. Check its operation once a day.
140.5 LVR50-V19 22 80 120 169 C F E Breathing port M5 x 0.8 J Tube extensions 4 x 7 Mounting hole 1/8 (Rc, NPT) Pilot port A H D B G Breathing port M5 x 0.8 Model A B C D E LVR20-T07(06) 40 40 49.3 68 20.1 LVR40-T11(10) 82.5 82.5 89 115 33 IN C F Model F G H J K LVR20-T07(06) 8 27 56 33.5 126.2 LVR40-T11(10) 14 64.5 100 40 183.3 E K J J Breathing port M5 x 0.8 5 Applicable Fluids Regulator
Air pressure may not rise with an air compressor of smaU capacity. 8 When source air is very dirty, use a main line filter (Series AFF) as a prefilter. When a reciprocating type compressor is used, use a main line filter(Series AFF) as a prefilter. Use an air compressor with the following capacity: AMH150 AMH650 100.Q.
Therefore, if an air compressor has a low air delivery, the pressure may not be sufficient. Auto Drain Caution The auto-drain may not function properly, depending on the quality of compressed air. Check its operation once a day. Cleaning of Ventilation Area Caution Remove dust from the ventilation area once a month using a vacuum cleaner or an air blow nozzle. 14-18-12