SMC Corporation of America
Elite Part Number Search
Search Results "ISE70-N02-L2-SY"

Part Number Description: LEAD WIRE R/ANGLE W/M12 CONN   Product Line: I   Product Line Description: INSTRUMENTATION   Family Code: 840   Family Description: ISE70/75 PRESSURE SWITCH   Class Code: 21   Part Code: 1   Reference Code:  J   Click here to report information errorImage shown may not match exact part number

. : The display above is an example of when [MPa] is selected for the ISE70 (1 MPa range) with the unit switching function. : When the actual pressure is smaller than the displayed value in the upper line, zero will be displayed. Example: 1 MPa range P_1 = 0.015 [MPa], H_1 = 0.01 [MPa], zero cut-off 1.0% Press the button to set. Return to function selection mode.

to 1 MPa ZSE20 ISE20 Withstand pressure 1.5 MPa ZSE30 ISE30 Minimum display/setting unit 0.01 MPa Applicable fluid Air, Non-corrosive gas, Non-flammable gas ZSE40 ISE40 12 to 24 VDC 10%, Ripple (p-p) 10% or less (With power supply polarity protection) Power supply voltage ZSE10 ISE10 Current consumption 55 mA or less (at no load) Switch output NPN or PNP open collector output: 1 output ISE70

Pressure Range: 0 to 1 MPa, Piping: G 1/4, Output Specification: Switch Output 1 + Switch Output 2 [NPN or PNP Switching Type], Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: Lead Wire with M12 Connector; Straight, 5 m, Bracket: Bracket A, Interchangeable with ISE70, Operation Manual/Calibration Certificate: -

Pressure Range: 0 to 1 MPa, Piping: Rc 1/4, Output Specification: Switch Output 1 + Switch Output 2 [NPN or PNP Switching Type], Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: Lead Wire with M12 Connector; Right-angled, 5 m, Bracket: Bracket A, Interchangeable with ISE70, Operation Manual/Calibration Certificate: -

Pressure Range: 0 to 1 MPa, Piping: Rc 1/4, Output Specification: Switch Output 1 + Switch Output 2 [NPN or PNP Switching Type], Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: Lead Wire with M12 Connector; Straight, 5 m, Bracket: Bracket A, Interchangeable with ISE70, Operation Manual/Calibration Certificate: None

Pressure Range: 0 to 1 MPa, Piping: Rc 1/4, Output Specification: Switch Output 1 + Switch Output 2 [NPN or PNP Switching Type], Unit Specification: SI Unit Only, Lead Wire: Lead Wire with M12 Connector; Right-angled, 5 m, Bracket: Bracket A, Interchangeable with ISE70, Operation Manual/Calibration Certificate: -

Pressure Range: 0 to 1 MPa, Piping: G 1/4, Output Specification: Switch Output 1 + Switch Output 2 [NPN or PNP Switching Type], Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: Lead Wire with M12 Connector; Right-angled, 5 m, Bracket: Bracket A, Interchangeable with ISE70, Operation Manual/Calibration Certificate: -

Pressure Range: 0 to 1.6 MPa, Piping: NPT 1/4, Output Specification: Switch Output 1 + Switch Output 2 [NPN or PNP Switching Type], Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: Lead Wire with M12 Connector; Straight, 5 m, Bracket: Bracket A, Interchangeable with ISE70, Operation Manual/Calibration Certificate: -

Pressure Range: 0 to 1 MPa, Piping: G 1/4, Output Specification: Switch Output 1 + Switch Output 2 [NPN or PNP Switching Type], Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: None, Bracket: Bracket A, Interchangeable with ISE70, Operation Manual/Calibration Certificate: -

Pressure Range: 0 to 1.6 MPa, Piping: Rc 1/4, Output Specification: I/O Link: Switch Output 1 + Switch Output 2 [Switch Output: NPN or PNP Switching Type], Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: Lead Wire with M12 Connector; Right-angled, 5 m, Bracket: Bracket A, Interchangeable with ISE70, Operation Manual/Calibration

Pressure Range: 0 to 1.6 MPa, Piping: Rc 1/4, Output Specification: Switch Output 1 + Switch Output 2 [NPN or PNP Switching Type], Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Lead Wire: Lead Wire with M12 Connector; Straight, 5 m, Bracket: Bracket A, Interchangeable with ISE70, Operation Manual/Calibration Certificate: -

dimensions D2 L1 L2 L3 A M Applicable tubing O.D.

M2 8 4.2 Applicable tubing L2 M2 L2 Different Diameter Tee: KQ2T Applicable tubing Applicable tubing O.D.

M2 8 4.2 Applicable tubing L2 M2 L2 Different Diameter Tee: KQ2T Applicable tubing Applicable tubing O.D.

400 Mer L2 (mm) Rolling Yawing m 200 L2 Mer 0 2 4 6 8 10 m Transfer load m (kg) 3000 a = 1000 2000 L3 (mm) L3 1000 a = 2000 m a = 3000 Mey a 0 2 4 6 8 10 Transfer load m (kg) Refer to page 145 for deflection data. 2 Standard Motor/Horizontal Mount Specification Series LJ1H10 Dimensions/LJ1H101PB Scale: 15% 10 6 Work piece mounting reference plane LJ1 LG1 LX LC6D/LC6C Switches LC1 80 5H10

400 Mer L2 (mm) Rolling Yawing m 200 L2 Mer 0 2 4 6 8 10 m Transfer load m (kg) 3000 a = 1000 2000 L3 (mm) L3 1000 a = 2000 m a = 3000 Mey a 0 2 4 6 8 10 Transfer load m (kg) Refer to page 145 for deflection data. 2 3 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com

Dimensions Space saving branch tee: LQ3T-SB Metric Size (L2, L2) 2 x B Model Applicable tubing O.D.

Dimension Formula L n 10 9 8 7 6 5 4 3 1 2 P , R1, R2 port n: Stations L1 = 56n + 64 L2 = 56n + 80 n: Stations L1 = 56n + 90 L2 = 56n + 106 L1 624 568 512 456 400 344 288 232 120 176 1/2 L2 640 584 528 472 416 360 304 248 136 192 L1 650 594 538 482 426 370 314 258 146 202 3/4 L2 666 610 554 498 442 386 330 274 162 218 ( ): 3/4 Dimensions inside are for rubber seals. 3-10-28 29 ISO Standard

MQR M2 8 4.2 Applicable tubing a L2 M2 L2 T Different Diameter Tee: KQ2T Applicable tubing b Effective area (mm2) Nylon Urethane Applicable tubing O.D.