Soft nylon Polyurethane KAH23-M5 17 8.5 14 13 2.1 M5 X 0.8 M6 X 1.0 7 17.5 12.5 8.5 3.4 2.9 4 3.2 1 8 KAH23-M6 KAH23-U01 8 10 17 KAH04-M5 M5 X 0.8 M6 X 1.0 9.5 14 13 2 4 4 8 KAH04-M6 17.5 4 1 8 18.5 13.5 KAH04-U01 5 14 10 10 16 5.6 5.6 1 4 KAH04-U02 16.5 10.5 10 18.5 KAH06-M5 M5 X 0.8 M6 X 1.0 15 14 4 4 11.5 3 10 KAH06-M6 19 1 8 14.5 KAH06-U01 5 12 6 19.5
Colors indication Longer lengths available upon request Color Black White Red Blue Yellow Green Symbol B W R BU Y G T0645 6 4.5 36 T1613 16 13 100 T0604 6 4 24 T1209 12 9 75 T0425 4 2.5 13 T0806 8 6 48 T0403 4 3 25 T1075 10 7.5 60 Model O.D. mm I.D. mm Min. bending radius mm Length 20m 100m Roll Reel Specifications Operating fluid Max. operating pressure Burst pressure Air, Water 218psi
TEL: 317-899-4440 FAX: 317-899-3102 GERMANY SMC Pneumatik GmbH Boschring 13-15 D-63329 Egelsbach, Germany TEL: 06103-4020 FAX: 06103-402139 CANADA SMC Pneumatics (Canada) Ltd. 6768 Financial Drive Mississauga, Ontario, L5N 7J6 Canada TEL: 905-812-0400 FAX: 905-812-8686 ITALY SMC Italia S.p.A.
H 25 3H9 depth 3 +0.025 0 4 3H9 depth 3 +0.025 0 (mm) N H I J M Z ZZ Model MXF12-20 4 22 11 36 65 65 76 MXF12-30 4 30 12 45 75 75 86 MXF12-50 6 65 13 80 111 111 122 142 Low Profile Slide Table Series MXF Dimensions: MXF16 Stroke adjuster at retraction end Stroke adjuster at extension end Width across hexagon socket hole 3 Width across flats 8 MXH N 2 ( 1) x 35 24 MXU Note) Blanking plug
, 11, 12 and 13, which can be ordered using the kit number for each cylinder bore size. 2 Series MHS2 2 Finger Air Gripper Gripping Point The work piece gripping point distance should be within the gripping force ranges given for each pressure in the effective gripping force graphs below.
M5, M6 Soft nylon Polyurethane KAH23-M5 17 8.5 14 13 2.1 M5 0.8 M6 1.0 7 17.5 12.5 8.5 3.4 2.9 4 3.2 1 8 KAH23-M6 KAH23-U01 8 10 KAH04-M5 M5 0.8 M6 1.0 17 9.5 14 13 2 4 4 8 KAH04-M6 17.5 4 1 8 KAH04-U01 18.5 13.5 5 14 10 16 10 5.6 5.6 1 4 KAH04-U02 16.5 10.5 10 Uni thread KAH06-M5 M5 0.8 M6 1.0 18.5 15 14 3 11.5 4 4 10 KAH06-M6 19 1 8 KAH06-U01 14.5 5 12 6 19.5 17 1 4 KAH06-U02 13 17 14 12
In order to prevent damage due to the breakdown and 13. Radiant heat from strong heat supplies such as a furthe malfunction of the driver and its peripheral devices, a backup system should be established previously by giving a multiple-layered structure or a fail-safe design to the equipment, etc. nace, direct sunlight, etc., should not be applied to the product.
13 13 13 0.75 x 4 1 x 4 0.9 x 8 0.75 x 4 0.9 x 8 1 x 4 1.1 x 8 R 1/8 R 1/8 R 1/8 R 1/4 R 1/4 R 1/4 R 1/4 12 12 12 14 14 14 14 18 18 18 20 20 20 20 D 2 Connection thread H1 A L1 Reference dimensions after R thread installation. 862 Nozzles for Blowing KN Series Sensing Heads Standard sensing head/KNP (mm) Applicable tubing O.D.
Refer to back page 50 for Safety Instructions and pages 13 to 16 for Temperature Control Equipment Precautions. Operating Environment/Storage Environment Warning Warning 1. Do not use in the following environment as it will lead to a breakdown.
Note 1 Body A Zinc alloy 2 Handle Brass Electroless nickel plated 3 Body B Brass Electroless nickel plated 4 Needle Brass Electroless nickel plated 5 Needle guide Brass Electroless nickel plated (1) 6 Seat ring Brass Zinc chromate plated (3) Meter-out Steel (2) 7 Lock nut Black zinc chromate plated Meter-in 8 U seal HNBR 9 O-ring NBR 10 O-ring NBR 11 O-ring NBR 12 01 to 04 type Bushing PBT 13
No.PF-OMM0004-D / / PF3W7## SMC 2 11 13 14 16 17 19 21 24 26 26 F1 OUT1 60 F2 OUT2 36 F3 42 F10 43 F20 47 F22 48 F30 50 F80 51 F81 52 F82 53 F90 54 F98 55 F99 56 57 61 61 65 65 71 79 81 88 -1No.PF-OMM0004-D (ISO/IEC) (JIS) 1 2 1) ISO 4414:Pneumatic fluid power -General rules relating to systems.
(Refer to Page 41) Output does not turn ON Air leakage Connect piping correctly and eliminate any air leakage. Setting is not correct Perform setting correctly. (Refer to Page 41) Output stays ON (Does not turn OFF) Clogged piping Apply pressure lower than the withstand pressure to eliminate the cause of clogging of piping. Incorrect wiring Connect wires correctly.
OUT1 output mode selection in Initial Setting on page 16-2-41. SET Press the SET button.
Caution Combinations of Solenoid Valve, Manifold Gasket and Manifold Base Combinations of Blanking Plate Assembly and Manifold Base Body ported Base mounted Manifold gasket and screw assembly VK300-41-1A VK300-41-2A Common SUP/ Common EXH Common SUP/ Individual EXH Type 40(VV3K3-40): Base mounted (A port bottom ported) Type 20(VV3K3-20): Body ported (A port top ported) Type 42(VV3K3-42):
Black N.C.: Gray M5 x 0.8 Barb fitting Applicable tubing: T0604 B B O S 1/4 10 One-touch fitting Width across flats 17 O S Accessory specification Standard specification Panel mount With auto drain With pressure gauge Bracket mounting size Port size Model C 48 73 86 92 93 A 25 40 53 70 75 D 25 52 59 75 75 B 108 160 201 239 242 E 28 40 57 73 73 P 30 44 46 54 56 K 0 5 3.5 1.5 1.2 M 25 30 41
A GR-S-010(10g) -7 5. -8-9 -8 -9 12 - , 3 6. 6-1. 1) 2) 3) 4) 5) 6) 7) 8) 9) 10) 11) 12) 13 - / 6-2. (M4),90 , -9 M4 1.5Nm -10 14 - 6-3. 5080 O 6-3-1. 4 50 : 12.5Nm 63 : 24.5Nm 80 : 42.0Nm -11 6-3-2. 1) -12 -12 2) 15 - 6-3-3. GR-S-010(10g),GR-S-020(20g) 1) 2) 3)O 4) -13 -13 6-3-4. 1)() -14 2)() -14 16 - 6-4. 6-4-1. B , 1 6-4-2. 7. 7-1.
3 14 4 15 5 16 NBR 6 17 7 18 8 A 19 9 B 20 10 21 11 22 1 12 2 13 3 14 4 15 5 16 NBR 6 17 7 18 8 A 19 9 B 20 10 21 11 22 -15- 1 14 2 15 3 16 4 17 5 18 6 19 NBR 7 20 8 21 9 A 22 10 23 11 24 12 25 13 -16- 3. 3.1. 1 I/O LEC-CN5-* / PLC 1 2 DC24V CN5 1 LE-C*-*-* LE-C*-*S-* CN4 CN3 CN2 120.3 120.3 mm mm 200 200
(Figure-13) Pick and pull. Figure-13 2) Tube gasket Pry it out with a precision screwdriver. 15 - 6-3-3. Grease application Caution Use SMC standard grease.
Then reapply the power supply and push MIDDLE button. 3 positions : See the circuit on page 13. 5 positions : See the circuit on page 25. ( ) Check the voltage and adjust it if necessary and then perform alarm reset. Power supply voltage is excessive or lower than limit for operation.
Workpiece mass: 0.05 kg Pressure 0.6 MPa 30 0.5 25 0.4 Gripping force (N) 20 0.3 15 13 0.2 10 0.1 5 0 20 30 50 60 40 70 Gripping point L (mm) When MHY2-16D is selected, the gripping force is determined to be 13 N according to the gripping point distance (L = 35 mm) and the pressure (0.4 MPa).