Installation of Ionizer 1) Installation with bracket When installing the Ionizer with a bracket, secure it with M5 screws using the mounting holes on the bottom of the bracket (The screws need to be prepared by the user). Refer to "6. Dimensions" for details. The angle adjustment range of the bracket is 45 degrees in direction A, and 90 degrees in direction B.

If B is turned ON in 2. state, the output is turned OFF. If either A or B is turned ON, cylinder is actuated.

-17-4 5 Clean Speed Controller with One-touch Fitting Series AS-FPQ/FPG Construction Meter-out type M5 type Meter-in type M5 type AS ASP ASN AQ ASV AK ASS ASR ASF Component Parts No.

Symbol 2 to 8 10 to 16 40, 50 20 to 32 U C D B Flat Flat with ribs Deep Bellows B4 M4 x 0.7 Symbol Applicable cylinder model Female thread M5 x 0.8 B5 M6 x 1 B6 M8 x 1.25 B8 D R D R X11 ZC(D)UK 10 Application: Refer to Table (1). Nil ZC(D)UK 16/32 M10 x 1.25 B10 Note) -X11 Pad: 2 to 8 diameter and flat style only available.

WQ Edition B Safety Instructions Be sure to read the Handling Precautions for SMC Products (M-E03-3) and Operation Manual before use.

A (2) Model T D1 H1 L4 (1) Applicable tubing O.D. d (g) Weight H2 D2 L1 L2 L3 M AS121F-M5-06W2 AS221F-01-06W2 AS221F-01-08W2 AS221F-01-10W2 AS221F-02-06W2 AS221F-02-08W2 AS221F-02-10W2 AS321F-02-06W2 AS321F-02-08W2 AS321F-02-10W2 AS321F-02-12W2 AS321F-03-06W2 AS321F-03-08W2 AS321F-03-10W2 AS321F-03-12W2 AS421F-04-10W2 AS421F-04-12W2 11.6 6 9 13.5 22.9 11.7 28.8 26 25.2 22.4 18.1 8 6 9.6 M5

VVPA4 5 0 04 04 1 Thread type Nil Rc G NPT NPTF VP 5 port Air operated manifold F N T 5 Base size Rc A, B Port size Rc 3 4 6 1 VVPA450 Symbol 04 Port size VVPA460 1 2 3 4 Mixed 1 06 10 M (2) Piping Note 2) In the case of mixed specifications, indicate M and specify port location sparately on a manifold specification sheet.

Lead wire length symbols: 0.5 m Nil (Example) M9NW 1 m M (Example) M9NWM 3 m L (Example) M9NWL Since there are other applicable auto switches than listed above, refer to page 361 for details. For details about auto switches with pre-wired connector, refer to pages 1648 and 1649. The D-A9ll/M9lll auto switches are shipped together, (but not assembled).

When connecting wire, be careful because using lead wire that is outside of compatible lead wire ranges, or that are tightened to anything other than the proper torque, creates a risk of defective contact and other problems. -15No.SJ2000-OMM0001-B -16No.SJ2000-OMM0001-B -17No.SJ2000-OMM0001-B -18No.SJ2000-OMM0001-B -19No.SJ2000-OMM0001-B -20No.SJ2000-OMM0001-B -21No.SJ2000-OMM0001-B -22No.SJ2000

Right angle type cable connector 3 m 52 10 ARJ (33) Straight type cable connector 3 m AR425 to 935 52 12.5 ARX AMR Setting part ARM 10 M12 x 1 Cable connection thread (Plug type) 5.5 8 ARP 111 11 Digital pressure display IR-A M5 x 0.8 Solenoid valve EXH Breathing IR M4 x 0.7 depth 8 F.G.

(B)). Fig. (A) When air is supplied to the exhausted cylinder, the air causes the check valve to close. Also, because the piston valve is fully closed due to the cylinder's low internal pressure, air is supplied gradually via the throttle of the set needle. Therefore, the cylinder operates slowly under meter-in control. Fig. (B) Fig.

Verify the specifications before use. 5 Branch port B (COM B) 4 (Input: Max. 32 points/Output: Max. 32 points per branch) Number of branches Connect the SI unit (with manifold valves) or input unit using a branch cable.

Description Application 010 1 [m] SAPA Socket side: Angled Plug side: Angled 1 Communication connector (Port1/IN) Caution Connect PROFINET line. 030 3 [m] GW unit specifications 2 Communication connector (Port2/OUT) 050 5 [m] 100 10 [m] Power supply connector Connector to supply power to the output devices such as solenoid valves and input and control equipment such as sensors.

type (4 cores) Cable connector 3 m (33) 52 12.5 Setting part 12 M12 x 1 Cable connection thread (Plug type) 4 10.5 11 108 Digital pressure display M5 x 0.8 Solenoid valve EXH M4 x 0.7 depth 8 F.G.

) The IN air passes the check valve to pressure boosting chambers A and B.

(EX245-EA2-1) No. 1 SI ON/OFF 2 3 4 SI 5 . 11 11 No.EX-OMU0020CN 2. . 2-1 EX245 DC24 V 1 msec IP65 CE RoHS AC500 V1 FE DC500 V10 M FE -1050 -2060 35%85%RH 1057 Hz0.75 mm p-p 57150 Hz49 m/s 2 XYZ 2 2 XYZ 3 () 147 m/s 12 No.EX-OMU0020CN 3. 3.1. 8 VQC4000 7 2 x M5 ( = 1.5 Nm) 2 x M5 (SI = 1.5 Nm) 4 x M* . 3-1 13 No.EX-OMU0020CN 3.1.1.

H4 S y m b o l Initial power / Power 100 VAC 200/40 200/50 400/100 600/150 200 VAC 800/40 800/50 1600/100 2400/150 consumption (W) Heater assembly number XL1A25-60S-1 XL1A25-60S-2 XL1A25-60S-2 XL1A25-60S-3 XL1A25-60S-2 No. of heater assemblies 1 pc. 1 pc. 1 pc. 1 pc. 2 pcs.

B H Part no. B H 10 Y-J010B 15.2 8 21 M4 x 0.7 CP95 SNJ-006B 16 Y-J016B 6 NTJ-006A 16.6 11 21 M5 x 0.8 9.2 8 M6 x 1.0 4 6 5.5 6.4 M3 x 0.5 2.4 SNJ-010B 10 NTJ-010A 12.7 11 M8 x 1.0 4 10 7 8.1 M4 x 0.7 3.2 NDd9 NDH10 R1 NX U1 Part no.

How to replace A, B port fitting assembly By replacing manifold block fitting assemblies or the threaded port block assembly of a type 43(P) manifold, the port size of the A and B ports can be changed. To replace these parts, remove the clip with a flat head screwdriver after the valve has been removed.