0.25 0.15 b 0.13 0.13 0.17 0.13 0.13 0.17 0.15 0.11 0.14 0.15 0.14 0.14 Cv 1.4 2.1 2.2 1.4 2.1 2.2 1.4 2.0 2.4 1.5 2.2 2.5 Cv 1.4 1.9 2.4 1.4 1.9 2.4 1.3 1.7 2.2 1.2 1.5 2.2 1 8 Rc VSA4130-02 VSA4130-03 VSA4130-04 VSA4230-02 VSA4230-03 VSA4230-04 VSA4330-02 VSA4330-03 VSA4330-04 VSA4430-02 VSA4430-03 VSA4430-04 2 position single VA 3 8 1 8 Rc 0.75 1 8 Rc 1 8 Rc SA 2 position double 3 8 1
For Water Digital Flow Switch Series PF2W How to Order Integrated Display Type PF2W7 20 03 27 M Flow rate range Thread type 04 20 40 11 0.5 to 4 L/min 2 to 16 L/min 5 to 40 L/min 10 to 100 L/min Unit specifications Nil N F Rc NPT G With unit switching function Note1) Fixed SI unit Note2) Nil M Lead wire (Refer to page 322.)
32 50 50 7 60 120 96 118 1 2, 3 4 82 68 88 92 1 181 53 12 81 70 35 36 66 52 9 66 140 96 133 DC C Model VS3135-02 VS3135-03 VS3135-04 VS3145-04 VS3145-06 A B Port size Rc 1 4, 3 8, 1 2 163 64 50.8 196 68 60.5 1 2, 3 4 4-16-7
/5 to 100 50 to 100/10 to 100 12, 16, 20, 25 32, 40, 50, 63 80, 100 RQ Double rod CQ2W 7-6-25 MU Spring return/ 12, 16, 20 25, 32, 40 50 Single acting 12 to 40/5, 10 50/10, 20 D7-6-42 Spring extend CQ2 -X Non-rotating Rod 12, 16/5 to 30 20, 25/5 to 50 32, 40/5 to 100 50, 63/10 to 100 12, 16, 20 25, 32, 40 50, 63 Single rod CQ2K 7-6-62 20Double acting Data 12, 16, 20 25, 32, 40 50, 63 12,
25.5 33 26 32 32.5 32 34 36 37.5 37 39 41 42 43 44.5 46.5 46.5 48 50 4 9 4 9 10 8 10 19 32 11 19 32 25 25 32 58 27 35 61 15 22.5 14.5 20.5 20.5 18 20.5 24.5 26.5 22 26 28 24 27 29 33 27.5 29.5 33.5 2.3 2.5 2.3 2.8 3.6 2.3 15.5 15.5 8 10 8 10 10 16.5 16.5 9.6 1 8 1 8 10-32 UNF 5 32 10.4 16 17 1 8 3 16 1 8 11.4 16.5 18 10-32 UNF 11.11 Connection thread 1 8 K 1 4
Name Alarm flag 1 Bit 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 Name Alarm flag 2 Bit 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 Name Alarm flag 3 Bit 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 Name Alarm flag 4 Bit 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 Name Alarm flag 5 Bit 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 Bit Name Explanation 0 Low tank fluid level 1 CH1 abnormal high circulating fluid temp. 2 Reservation
Example 1) ASCII mode Received function code: 04(0 0100) ASCII code 30h, 34h Abnormal function code: 841000 0100 ASCII code 38h, 34h Example 2) RTU mode Receive function code: "04" (0 0100) Abnormal function code: "84" (1000 0100 2) Error Code Assign error code below. 01 : Function code of a command is outside the standard 02 : The specified address of register is outside the range. 03 :
MK-A012 MK-A016 Bore size (mm) 12 16 20 25 32 40 50 63 12 70 87 16 100 123 20 250 290 25 280 320 32 500 525 40 595 640 50 1100 1350 63 1520 1805 Clamp bolt, Hexagon socket head cap screw, Hexagon nut, Spring washer MK-A020 MK-A032 Additional Weight MK-A050 Unit: g 50 7 46 13 350 345 63 17 46 25 350 531 40 6 21 7 200 198 20 6 10 2 100 133 25 7 10 3 100 153 32 7 21 5 200 166 16 32
9, @0, @2, @3, @4, @5 NBR 32 RHC32-PS @4 O-ring NBR 40 RHC40-PS @5 O-ring Stainless steel for 20, 25 Carbon steel for 32, 40 10-6-10 10 High Power Cylinder Series RHC Construction: 50 to 100 u q !2 i e !0 o w !6 !5 !4 !3 y r t !
(mm) 6 8 10 12 4 (1) AS221FE-01 AS231FE-01 R 1/8 20, 25, 32 AS221FE-02 AS231FE-02 R 1/4 20, 25, 32, 40 AS321FE-03 AS331FE-03 R 3/8 40, 50, 63 AS421FE-04 AS431FE-04 63, 80, 100 R 1/2 Note 1) Elbow type only Note 2) Distinction between meter-out/meter-in types by appearance Those are distinguished by the lock nut.
(mm) 4 6 8 10 12 (1) AS221FE-01 AS231FE-01 20, 25, 32 R 1/8 AS221FE-02 AS231FE-02 20, 25, 32, 40 R 1/4 AS321FE-03 AS331FE-03 40, 50, 63 R 3/8 AS421FE-04 AS431FE-04 63, 80, 100 R 1/2 Note 1) Elbow type only Note 2) Distinction between meter-out/meter-in types by appearance Those are distinguished by the lock nut.
32 13 10.5 10 45 10 17 26 32 32 46.5 5.5 10 6 22 19.5 32 13 10.5 11 45 12 17 26 40 56.2 7 12 8 24 21 41 16 13.5 12.5 50 14 22 32 Note) For 32, a trunnion pivot bracket NA (42.5) is used as standard.
32 13 10.5 10 45 10 17 26 32 32 46.5 5.5 10 6 22 19.5 32 13 10.5 11 45 12 17 26 40 56.2 7 12 8 24 21 41 16 13.5 12.5 50 14 22 32 Note) For 32, a trunnion pivot bracket NA (42.5) is used as standard.
32 13 10.5 10 45 10 17 26 32 32 46.5 5.5 10 6 22 19.5 32 13 10.5 11 45 12 17 26 40 56.2 7 12 8 24 21 41 16 13.5 12.5 50 14 22 32 Note) For 32, a trunnion pivot bracket NA (42.5) is used as standard.
Applicable bore size (mm) M22 x 1.5 M8 x 1.25 SOR-20 NT-02 20 20 5 13 8 30 26 15 12.5 26 M24 x 1.5 M10 x 1.25 SOR-25 NT-03 25 25/32 6 17 8 36.9 32 19.6 16.5 32 M30 x 1.5 M14 x 1.5 SOR-32 NT-04 32 40 8 22 9 43.9 38 25.4 21.0 38 M33 x 2.0 M18 x 1.5 SOR-40 NT-05 40 50/63 11 27 11 47.3 41 31 26 41 M22 x 1.5 NT-08 80 13 32 37 31 M26 x 1.5 NT-10 100 16 41 47.3 39 1210 High Power Cylinder Series
D-G5NBL BA-01 BA-02 BA-32 BA-04 BA-05 BA-06 BA-08 BA-10 D-B7/B80 D-B73C/B80C D-G79/K79 D-K79C BM1-01 BM1-02 BM1-32 BM1-04 BM1-05 BM1-06 Note) Two kinds of auto switch mounting brackets are used as a set.
0 -0.021 0 -0.021 0 -0.021 0 -0.025 0 -0.025 0 -0.025 40 45 23 10 60 44 18 25 14 17.5 9.5 M8 x 1.25 18 10 20 M14 x 1.5 30 22 1/4 37 106 11 15 17 50 50 25 9 73 53 20 28 17 17 13 M10 x 1.5 20 10 22 M16 x 1.5 30 26 3/8 43 112 11 15 19 63 55 28 8 80 60 22.4 30 17 17 13 M10 x 1.5 22 10 25 M18 x 1.5 30 26 3/8 47 116 11 15 21 80 65 32 8 100 75 28 32 22 20 15 M12 x 1.75 26 13 29 M22 x 1.5 35 30
BA 32 BA 04 BA 05 BA 06 BA 08 BA 10 BA 01 BA 02 BM1 01 BM1 02 BM1 32 BM1 04 BM1 05 BM1 06
(Normally open) B Port size Rc (Nominal size) VP3145 VP3165 VP3185 Symbol 03 (10A) 3 8 (15A) 1 2 (20A) 3 4 (25A) 1 Electrical entry 04 CE-compliant 06 10 12 14 20 TL D T G Grommet Conduit terminal DIN terminal Conduit terminal with indicator light SYJ (32A) 1 4 1 (40A) 1 2 1 VQZ TS (50A) 2 Symbol Internal pilot
Set the mounting band perpendicularly to cylinder tube. 20 50 63 80 100 25 32 40 D-B7/B80 8 10 9 10 10 11 D-B73C/B80C D-C7/C80 8 10 9 10 10 11 D-C73C/C80C 8 10 9 10 10 11 D-B5/B64 11 11 MX Mounting correctly Mounting incorrectly 13 13 14 14 14 17 D-B59W 18 16 D-G79/K79 8 10 9 10 10 11 Auto Switch Mounting Bracket Part No.