12-REA40 12-REA50 50 1300 Non-lube 200, 250, 300, 350, 400, 450, 500, 600, 700, 800, 900, 1000 12-REA63 63 Note 1) Stroke exceeding the standard stroke but below the maximum manufacturable stroke is available as special orders.

Eccentric distance Stroke Operating pressure: 0.5 MPa 1000.0 Plate allowable lateral load (N) 100.0 100 Load weight (kg) 63 63 50 10.0 50 40 32 40 1.0 32 10 0.1 10 100 1000 Maximum piston speed (mm/s) 0 10 20 30 40 50 60 70 80 90 100 110 120 Stroke + Eccentric distance (mm) Relationship between Number of Needle Rotations and Piston Speed 32, 40 50, 63 800 800 32 32 50 700 700 600 600 63 Piston

Bore size CJ2 series Pressure 0.5 MPa Load factor 50% Stroke 60 mm CM2 series Pressure 0.5 MPa Load factor 50% Stroke 300 mm MB, CA2 series Pressure 0.5 MPa Load factor 50% Stroke 500 mm Average speed (mm/s) Series 6 10 16 20 25 32 40 40 50 63 80 100 800 700 600 500 400 300 200 100 0 Perpendicular, upward actuation Horizontal actuation VQ1101 Port size: 6 One-touch fitting 800 700 600 500

Bore size MB, CA2 series Pressure 0.5 MPa Load factor 50% Stroke 500 mm CM2 series Pressure 0.5 MPa Load factor 50% Stroke 300 mm CJ2 series Pressure 0.5 MPa Load factor 50% Stroke 60 mm Average speed (mm/s) Series 6 10 16 20 25 32 40 40 50 63 80 100 800 700 600 500 400 300 200 100 0 Perpendicular, upward actuation Horizontal actuation VQC1101 800 700 600 500 400 300 200 100 0 VQC2101 It

For Air 1.0 Downstream pressure of valve (P2) [MPa] Upstream pressure of valve P1z1.0 MPa 0.8 Subsonic 0.9 0.6 Critical pressure 0.8 0.7 Sonic 0.4 0.6 0.5 0.4 0.2 0.3 0.2 0.1 0 3/64 (1.2) 50 100 150 3/32 (2.4) 100 200 300 400 1/8 (3.2) 300 200 100 400 500 600 700 5/32 (4) 200 1, 000 800 400 600 7/32 (5.6) Series VXN2 250 500 7/32 (5.6) Series VXN3 500 1, 000 1, 500 2, 000 Flow rate Q [L/min

1000 25 200 400 600 800 1000 1200 1400 Flow rate Q [kg/h] ( ): Saturated steam holding heat (kcal/kg) ( ): Saturation temperature (C) For Water How to read the graph The pressure differential to generate a flow rate of 25 L/min water is as follows.

[L/min (ANR)] Discharge flow rate [L/min (ANR)] Suction flow rate [L/min (ANR)] Note 1) Air consumption [L/min (ANR)] Discharge flow rate [L/min (ANR)] 1,600 700 ---6 ---6 Discharge flow rate Discharge flow rate 1,400 Vacuum pressure [kPa] Vacuum pressure [kPa] 600 Vacuum pressure Vacuum pressure ---5 ---5 1,200 500 ---4 ---4 1,000 400 Suction flow rate Suction flow rate 800 ---3 ---3 300

Franklin Road Indianapolis IN 46226 (317) 899-4845 www.smcusa.com Call 1-800-SMC-SMC1 (1-800-762-7621) to reach the branch nearest you 2004 SMC Corporation of America, All Rights Reserved. All reasonable efforts to ensure the accuracy of the information detailed in this catalog were made at the time of publishing.

.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 45 95 150 170 250 350 450 770 960 Surface: Munsell N-5.5, Inner surface: Non coated Safety valve (1 pc.) R 1/2 R 3/4 R 11/4 R 2 R 1 Accessory (2) Rc 1/2 Valve for drainage (1 pc.) Pressure gauge (1 pc.)

RSH20, 32 Graphq Graphw 1.0 RSH32 RSH32 RSH32 Bore size 50, 63, 80/ m =0 Bore size 50, 63, 80/ m =0.1 RSH20 RSH20 RSH20 0.9 Operating pressure : P (MPa) 1300 1300 0.8 80 0.7 1200 1200 0.6 1100 1100 0.5 1000 1000 0.4 900 900 0.3 63 80 800 800 0.2 50 Weight : W (kg) Weight : W (kg) 700 700 0.1 600 600 100 200 300 400 500 0 63 500 500 Lateral load: W (N) 50 400 400 RSH50, 63, 80 300 300 1.0

pulse/rotation) Serial communication RS485 (Modbus protocol compliant) Memory EEPROM Lock control Forced-lock release terminal Cable length [m] I/O cable: 5 or less, Actuator cable: 20 or less Battery Nickel hydride secondary battery 3.6V Charging time: 72 hours Battery replacement guide (Note 3) 2 years Motor allowable RPM when power supply is shutoff [rpm] 800 400 200 100 Battery retention

repeatability [mm] 0.05 Lost motion [mm] Note 7) 0.2 or less Impact/Vibration resistance [m/s2] Note 8) 50/20 Actuation type Slide screw Guide type Sliding bushing Max. operating frequency [c.p.m] 60 Operating temperature range [C] 5 to 40 Operating humidity range [%RH] 90 or less (No condensation) Weight Motor size l20 l28 Motor type Step motor (Servo/24 VDC) Encoder Incremental A/B phase (800

1000 100 25, 50, 75, 100, 125, 150, 175, 200, 250, 300, 350, 400, 450, 500, 600, 700, 800 1000 Unit: MPa Bore size (mm) 32 40 50 63 80 100 Min. operating pressure 0.02 0.01 Note 1) Intermediate strokes not listed above are also available.

Figure 18-1 SMD Cover 49 - IN20267 Figure 18-2 Defualt Switch Position all up 50 - IN20267 Revision History Revision Description Date Author(s) 1.0 Initial release for Ethernet/IP MPC 010/11/2016 SMC US EPG SMC Corporation of America 10100 SMC Boulevard Noblesville, IN 46060 Phone: 1-800-SMC-SMC1 (1-800-762-7621) URL: www.smcusa.com 51 -

Flow Rate Characteristics Relief Characteristics IR1020-01-A Supply pressure: 0.7 MPa IR1020-01-A Back pressure: 0.7 MPa 0.7 0.7 0.6 0.6 Set pressure [MPa] Set pressure [MPa] 0.5 0.5 0.4 0.4 0.3 0.3 0.2 0.2 0.1 0.1 0 0 200 400 600 800 0 0 50 100 150 200 Flow rate [L/min (ANR)] Flow rate [L/min (ANR)] Pressure Characteristics Supply pressure: 0.3 to 1.0 MPa Set pressure: 0.2 MPa Flow rate:

3 Step Motor Controller JXCE1/91/P1/D1/L1 Series Specifications Model JXCE1 JXC91 JXCP1 JXCD1 JXCL1 Network EtherCAT EtherNet/IP PROFINET DeviceNet IO-Link Compatible motor Step motor (Servo/24 VDC) Power supply Power voltage: 24 VDC 10% Current consumption (Controller) 200 mA or less 130 mA or less 200 mA or less 100 mA or less 100 mA or less Compatible encoder Incremental A/B phase (800

22 22 26 26 4 4 6 6 6 8 8 10 10 10 10 10 12 12 12 16 16 20 20 1 1.5 1 1.5 2 1.5 2 2.5 3 3.5 4 6 3.5 4 6 4 6 4 6 D H2 H1 M L1 Nozzle with male thread/KN (mm) Model Nozzle size D Connection thread L1 A Width across flats H1 Weight (g) Connection thread KN-R01-100 KN-R01-150 KN-R02-100 KN-R02-150 KN-R02-200 KN-R02-250 KN-R02-600 KN-R03-400 KN-R03-600 KN-R04-400 KN-R04-600 KN-R06-600 KN-R06-800

Heating Capacity Circulating fluid: Water, Flow rate: 1 L/min Circulating fluid: Water, Flow rate: 1 L/min, When constant fan speed mode is selected 800 800 700 700 Heating capacity [W] Heating capacity [W] 600 600 Ambient temperature 35C Ambient temperature 35C 500 500 400 400 300 300 Ambient temperature 25C Ambient temperature 25C 200 200 100 100 0 0 10 20 30 40 50 60 70 Circulating fluid

Polyester band Forklift insertion side Cardboard box 800 mm Less than 150 mm 300 mm or more or more Wooden skid Forklift insertion side Less than 150 mm Model Weight [kg] Dimensions [mm] HRLE050-A-20 150 Height 1320 x Width 580 x Depth 1240 HRLE050-W-20 143 HRLE090-A-20/40 176 HRLE090-W-20/40 170 300 mm or more 500 mm or more 2. Transporting with forklift 1.