12 V Solid state switch Relay, PLC 24 V Grommet Yes 12 V 5 V, 12 V 12 V 100 V or less 100 V IC circuit no Yes Relay, PLC 24 V 2-wire Reed switch Grommet 161
H 5 B C 100 S B F9N 1 Actuator configuration Number of auto switches/proximity switches Flat table type F 1 pc. 2 pcs. 1 2 Guide rod type P Slide table type S 6 pcs. 6 Guide type Direct acting guide H Auto switch/Proximity switch type Ball bushing B Without auto switch/proximity switch Nil With sensor plate, without proximity switch GN Proximity switches Motor type D-F9N (lead wire length
Output Specification: NPN Open Collector 2 Outputs + Analog Current Output, Unit Specification: Unit Selection Function, Initial value psi, Piping Specification: NPT 1/8, Lead Wire: -, Bracket: -, Operation Manual: -
Output Specification: S (NPN Open Collector 2 Outputs + Analog Current Output), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: N01 (NPT 1/8)
Operating pressure (MPa) U: Maximum speed (mm/s) Stroke (mm) Mode of operation Inclined operation Vertical operation Horizontal operation Review of load weight and operating pressure Lo Fn W Guide First tentative bore size determination F3 D1.6 x P First tentative bore size determination F2 D1.6 x P First tentative bore size determination F1 D1.6 x P WB Inclined operation W+WBWV PPV
Metric size Inch size 3.2 4 6 8 10 12 1/8" 5/32" 1/4" 5/16" 3/8" 1/2" AS1002FS V V V V V V AS2002FS V V V V AS2052FS V V V V AS3002FS V V V V V V V AS4002FS V V V V 1 Use caution at the max. operating pressure when using soft nylon or polyurethane tubing. (Refer to the Web Catalog for details.)
Flow Characteristics With DIN terminal block With terminal block Port size Flow characteristics 2 3 (A R) b Cv C [dm 3/(sbar)] 1 2 (P A) b Cv C [dm 3/(sbar)] 26 38 0.38 0.30 7.0 9.8 27 38 0.37 0.32 7.4 9.8 27 40 0.36 0.22 7.3 9.8 25 40 0.37 0.20 6.8 9.6 2 1 (A P) b Cv C [dm 3/(sbar)] 3 2 (R A) b Cv C [dm 3/(sbar)] 1/2 3/4 Port size Effective area (mm2) 2 3 (A R) 1 2 (P A) 235
Refer to gauge guide (P.94). 2PW 3PW Sample Order Number Port qIN wOUT eGauge port (Inlet) 2PW 3PW 01 S BP10 e V3 MPA FV4 FV4 FV4 FV4 Specifications BP1020 15 to 200 psig (0.1 to 1.4 MPa) BP1030 15 to 300 psig (0.1 to 2.1 MPa) BP1001 0.5 to 10 psig (0.0034 to 0.07 MPa) BP1002 1 to 30 psig (0.007 to 0.2 MPa) BP1010 5 to 100 psig (0.034 to 0.7 MPa) Operating Parameters Operating pressure Gas
The maximum detectable soeed is: V(m/s) = Auto switch response range (mm) X 1000 Loading time (ms) Wiring/current and voltage '1 . Ensure that the load is connected before connecting the power source. 2. Use as short a wire as possible. Using a long wire to reach the load could increase the inrush current when the switch is on and consequently shorten the switch life. 3.
AC (50/60 Hz) 100 V, 200 V, Other voltage (Option) 24 V, Other voltage (Option) 15% to +10% of rated voltage Class B or equivalent (130C) JIS Symbol PA DC Valve type Style N.C.
P P CM PTC PTC C01 FM PRS C02 OLR PC C11 ILS TB GFCI 12 3 13.S S 13 13.1 13.2 IDF15E1-20 L N PE M3 6.5mm 1.25mm 2 13 1 13.S 13.3 IDF15E-10-S PE N L TB CM ILS FM PTC OLR OLR ILS PTC PTC CM PRS C01 C02 TB C01 C02 C11 FM C11 PRS P 13 2 14.T T 14 14.1 IEC 14.2 AC200V, 1A (AC10mA, DC30mA) 14.3 ON 3 () 5 /1 () 14 1 14.T 14.4 PE 1 2 3 PE: LN: LN PE M3 6.5mm
How to Order 2 2 0 0 01 M AS Option Body size None With seal Nil S 1 2 2 Meter-out Meter-in M5 standard 1/8, 1/4 standard Type Direct cylinder elbow type Control type M5 and U10/32 are not available with seal.
Software warning 4 ) Indicates special care must be taken when using this element of software. 5 ) Indicates a special point which the user of the associate software element should be aware of. 6 ) Indicates a point of interest or further explanation. v PneuAlpha vi PneuAlpha Table of Contents Guideline. v 1.
P . 15-11-3 15-9-2 2 Speed Controller with One-touch Fitting Elbow Type/Universal Type Series AS How to Order 2 2 0 01 06 S AS 1F Nil Option Body size 1 2 3 4 M3, M5 standard 1/8, 1/4 standard 3/8 standard 1/2 standard None With seal Hexagonal lock nut Electroless nickel plated S K N If more than one option is required, write option part numbers in the order of S, K, N.
Body Needle V seal Lock nut Adjustment handle Insert bushing Nut Collar A 1 2 3 4 5 6 7 8 PFA PCTFE PTFE PVDF PVDF PFA PFA PFA Body class 2 y u y u B Dimensions A (B) (max.S) D H Port A 2 x G SMC (J) SMC C E F K Port B E A B C D E F G H J K S Model 48 60 72 LVN20 LVN30 LVN40 24 30 36 12 18 22 88 110 124 34.5 43 52 6 9 11 4 5 6 14 25 25 20 26 33 18 24 30 2.4 7.5 8.0 940 LQ1/LQ3/LVN/LQHB Series
R Thrust energy E2 m g S F S + m g S F S m g S Absorbed energy E E1 + E2 E1 + E2 E1 + E2 E1 + E2 Note 2) E 2 2 E 2 2 E 2 2 E 2 2 Equivalent mass Me Note 1) This is the momentary speed at which an object is impacting against a shock absorber.
OUT IN BUS COM A COM B COM C COM D F R P B U S O I R DIA BF SOL RUN GATEWAY UNIT EX500 SERIES 18 19 Switch setting Open the station number switch protective cover and set the switches with a sharp-pointed watchmakers screwdriver etc. NOTE 1. Be sure to turn off the power before setting the switches. 2. Be sure to set these switches before use.
[Example] 10-SYJ3123-5M-M3 VJ3000-13-1 Rated voltage 5 port DC AC (50/60Hz) 5 6 V S R 1 2 3 4 24 VDC 12 VDC 6 VDC 5 VDC 3 VDC 100 VAC 200 VAC 110 VAC [115 VAC] 220 VAC [230 VAC] For type "W", DC voltage is only available.
Hydraulic fluid 0 1 2 N W V Petroleum Water-glycol, Emulsion Phosphoric ester Note) N, W and V refer to the hydraulic fluid symbol indicated at the end of the element part number. Replacement Element Part No.
.) < Applicable Auto switches > Solid state auto switch D-M9N(V)-900M9P(V)-900M9B(V)-900 D-M9NW(V)-900M9PW(V)-900M9BW(V)-900 Reed auto switch D-A90-900 Fig 4. How to Mount and Move the Auto Switch Fig 4.