.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Piston speed V (mm/s) M2 = F2 x L2 ML1C/M2, M3 Moment (Nm) M3 = F3 x L3 Piston speed V (mm/s) (How to calculate the load ratio) A.
Type), Switch: None, Manual Override: Non-locking Push Type, A,B Port Size: L2 (ø2 Elbow Fitting Assembly, Upward Entry)
Rear plate N C D T A 2 x P (Rc, NPT, G) Q B E W S U M K L R I AP AB J AA A V Y + Stroke X Z + Stroke 8 x AF AC AD AE WH (Max.)
MPa MPa MPa P P P P K K K K C C C C U U U U O O O O S S S S H H H H L L L L to to to to Mounting angles other than 45, 135, 225 and 315 are available through the Made to Order (page 29).
PL-05-075 Wesola k/Warszaway, ul. Wspolna 1A Phone: 022-6131847, Fax: 022-613-3028 Czech SMC Czech.s.r.o. Kodanska 46, CZ-100 10 Prague 10 Phone: 02-67154 790, Fax: 02-67154 793 Hungary SMC Hungary Kft. Budafoki ut 107-113, 1117 Budapest Phone: 01-204 4366, Fax: 01-204 4371 Sweden SMC Pneumatics Sweden A.B.
Active face A (upper switch) becomes covered at open limit of travel and face K (lower switch) at closed limit.
AI Inlel pressure 0.7MPa /71 kgf/cm21 , outlel pressure 0.2MPa 1 2.0kgflcm21. flow rale 20 / min (ANR) AR2001-02 AR2001-02 0.25 -r-=:: lf~1 ~ "'" ~ :'.. ::;; 0.2 ~r. " 5 OJ> ~ o . 3k-1-j.-:=.
Chapter 6: Piping 6-1 Example of Recommended Pneumatic Horizontal mounting Vertical flat mounting Vertical overhead mounting 19 Recommended pneumatic components Bore Directional valve Brake valve Regulator Piping Silencer Speed controller 40 VFS240R VFS210 AR425 Nylon 8/6 AN200-02 AS4000-02 50 VFS240R VFS210 AR425 Nylon 10/7.5 AN200-02 AS4000-02 63 VFS340R VFS210 AR425 Nylon 12/9 AN300
nbe,ot so enords n :he case.t n red s I 19. use Lhe o.ror s,,m.o -K i \ : o$ Soleh hi' Lateral Plug in Style Manifold Series SVI 000/2000/3000/40W F r !
BA-32 BA-04 BA-05 BA-06 BA-08 BA-10 D-A3/A44 D-G39/K39 BD1-01M BD1-02M BD1-02 BD1-04M BD1-05M BD1-06M BD1-08M BD1-10M Note 1) Two kinds of auto switch mounting brackets are used as a set.
Applicable bore size C D d H Applicable bore size C D d H 5 12.5 15 26 30 M8 x 1.25 8 M22 x 1.5 26 13 20 20 SOR-20 NT-02 6 16.5 19.6 32 36.9 M10 x 1.25 8 M24 x 1.5 32 17 25/32 25 SOR-25 NT-03 8 21.0 25.4 38 43.9 M14 x 1.5 9 M30 x 1.5 38 22 40 32 SOR-32 NT-04 11 26 31 41 47.3 M18 x 1.5 11 M33 x 2.0 41 27 50 40 SOR-40 NT-05 11 26 31 M18 x 1.5 27 63 NT-05 13 31 37 M22 x 1.5 32 80 NT-08 16 39
(Including band and screw) MVGQ Bore size (mm) 20 25 32 40 50 63 80 100 CC Applicable auto switch RB D-C7, D-C80 D-C73C, D-C80C Reed J BMA2-020 BMA2-032 BMA2-040 BMA2-050 BMA2-063 BMA2-025 D-H7/H7C D-H7W D-H7NF/H7BAL Solid state DD-B5, D-B64, D-B59W Reed -X D-G5/K59/G5W/K59W BA-04 BA-32 BA-05 BA-06 BA-01 BA-08 BA-10 BA-02 Solid state 20D-G5NTL, D-G5BAL D-A3, D-A44 Reed BD1-04M BD1-02 BD1
Users system side To the thermo-chiller 24 VDC +24 VDC (Output) 1 2 +24 VDC (Input) EXT 24 VDC EXT 24 COM Power supply 14 24 COM (Output) 24 COM Run/Stop When using a user s power supply, connect the 24 VDC + side to pin 2 and the COM side of each contact input signal to the users power COM. 3 4.7 k External switch 16 4.7 k Operation mode request (Momentary) 4 4.7 k 24 VDC 6 Power supply
PSE56--28 Current output type 4 to 20 mA Allowable load impedance 500 or less (at 24 VDC) 100 or less (at 12 VDC) Brown LINE(+) Brown DC(+) Load Main circuit Main circuit (Analog output) 1 k Black OUT 12 to 24 VDC + 12 to 24 VDC + Load Blue LINE() Blue DC() Load Install the load either on the LINE (+) or LINE () side.
650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com ZSP ISA2 IS ZSE F/ISE --62(L)-(M) 50 60 50 60 ZSE F/ISE --70(L)-(M) 50 60 50 60 ZSM With analog output With auto shift input PF2 (Brown) DC (+) 1.2 k (Brown) DC (+) IF (Gray) Analog output (Gray) Auto shift input 6.8 k 1 k 12VDC to 24VDC 12 VDC to 24 VDC (Black) OUT 1 (Black) OUT 1 Data (White) OUT 2 (White) OUT 2
Note 4) VXP2130: Option C, K, Q, S only. 17-3-44 3 Series VXP21/22/23 Pilot Operated 2 Port Solenoid Valve For Air, Gas, Steam and Oil The VX series will be revised shortly. How to Order (Normally Closed) VXP21 0 VXP22 VXP23 Bracket Nil B None With bracket VC Model Thread connection sizes are available from 02 to 10.
(20 [C]) : 295 [K] (22 [C]) : 2.0 [K] (= T2 T1) : 60 [s/min] : Unknown [cal/h] [W] : Tap water* Heat generation amount by users equipment Q Circulating fluid Circulating fluid weight flow rate qm Circulating fluid weight volume ratio g Circulating fluid (volume) flow rate qv Circulating fluid specific heat C Circulating fluid outlet temperature T1 Circulating fluid return temperature T2
19.2 k/45.45 k/ 93.75 k/187.5 k/500 k/ 1.5 M/3 M/6 M/12 Mbps 156 k/625 k/ 2.5 M/5 M/10 Mbps 125 k/250 k/ 500 kbps Communication speed 4-branch input Specified file Note 2) EDS file GSD file 64/64 Possible to change depending on the switch setting 96/96 (3 stations, remote device station) Possible to change depending on the switch setting Occupied area (Number of inputs/outputs) 4-branch
Parenlneses CPA1 BN do Boot with Boot' BORE D E G'GB J K M MM N P H z.
Parenlneses CPA1 BN do Boot with Boot' BORE D E G'GB J K M MM N P H z.