-B 40 W 50 L/min 1000 Hz 0.55 0.4 High speed response required for both ON and OFF -E 80 W 100 L/min 650 Hz 0.55 0.55 -F 40 W 100 L/min 550 Hz 0.7 0.55 -J 80 W 150 L/min 600 Hz 0.6 0.75 -K 40 W 150 L/min 500 Hz 0.8 0.75 * Current needs to be limited.
1) B Note 2) K Note 3) N None DIN rail length specified Back pressure check valve Special wiring specifications (Except double wiring) With name plate (Side ported only) Manifold mounting D E DIN rail mounting Direct mounting Note 1) Specify DIN rail length with D at the end.
Note 4) Specify -K for wiring specification for cases below. All single wiring Single and double mixed wiring When there are stations which do not require wiring (e.g. single SUP spacer), specify the wiring specification in the manifold specification so that the number of the solenoids is 16 maximum.
K C37 1 25 L Stainless steel G 24 VDC DIN terminal With surge voltage suppressor Note) H 100 VAC J 110 VAC K 200 VAC L 230 VAC N 100 VAC Conduit terminal With surge voltage suppressor P 110 VAC Q 200 VAC R 230 VAC T 100 VAC Conduit With surge voltage suppressor U 110 VAC V 200 VAC W 230 VAC Z Other voltages Note) For the class H type DIN terminal, use it in combination with the connector
System), 1st Selection Supply Valve and Release Valve: K (N.C.
Type), 1st Nominal Nozzle Size: 0 (for Vacuum Pump System), 1st Selection Supply Valve and Release Valve: K (N.C.
Vacuum Pump System), 1st Selection Supply Valve and Release Valve: K (N.C.
Type), 1st Nominal Nozzle Size: 0 (for Vacuum Pump System), 1st Selection Supply Valve and Release Valve: K (N.C.
Pump System), 1st Selection Supply Valve and Release Valve: K (N.C.
System: Q (Vacuum Pump System for Manifold), Valves: K (Supply Valve; N.C., Release Valve; N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: C (Digital Pressure Switch for Vacuum, 0 to -101, PNP 2 Outputs), Connector: C (Common Wiring, Plug-in for Manifold), Vacuum, V Port: 07 (Inch Size, ø1/4" One-touch Fitting), Bracket: w/o Option, Pump System PE Port Female Thread: C (with Pump System
System: Q (Vacuum Pump System for Manifold), Valves: K (Supply Valve; N.C., Release Valve; N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: C (Digital Pressure Switch for Vacuum, 0 to -101, PNP 2 Outputs), Connector: C (Common Wiring, Plug-in for Manifold), Vacuum, V Port: 07 (Inch Size, ø1/4" One-touch Fitting), Bracket: w/o Option, Pump System PE Port Female Thread: w/o Option, Individual
System: Q (Vacuum Pump System for Manifold), Valves: K (Supply Valve; N.C., Release Valve; N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: C (Digital Pressure Switch for Vacuum, 0 to -101, PNP 2 Outputs), Connector: C (Common Wiring, Plug-in for Manifold), Vacuum, V Port: 06 (Metric Size, ø6 One-touch Fitting), Bracket: w/o Option, Pump System PE Port Female Thread: w/o Option, Individual
System: Q (Vacuum Pump System for Manifold), Valves: K (Supply Valve; N.C., Release Valve; N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: C (Digital Pressure Switch for Vacuum, 0 to -101, PNP 2 Outputs), Connector: C (Common Wiring, Plug-in for Manifold), Vacuum, V Port: 06 (Metric Size, ø6 One-touch Fitting), Bracket: w/o Option, Pump System PE Port Female Thread: w/o Option, Individual
System: Q (Vacuum Pump System for Manifold), Valves: K (Supply Valve; N.C., Release Valve; N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: C (Digital Pressure Switch for Vacuum, 0 to -101, PNP 2 Outputs), Connector: L (L-type Plug Connector, Lead Wire w/Connector & Lead Wire for Pressure Switch), Vacuum, V Port: 07 (Inch Size, ø1/4" One-touch Fitting), Bracket: w/o Option, Pump System PE
System: Q (Vacuum Pump System for Manifold), Valves: K (Supply Valve; N.C., Release Valve; N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: H (Digital Pressure Switch for Vacuum, -100 to 100, PNP 2 Outputs), Connector: L (L-type Plug Connector, Lead Wire w/Connector & Lead Wire for Pressure Switch), Vacuum, V Port: 08 (Metric Size, ø8 One-touch Fitting), Bracket: w/o Option, Pump System PE
System: Q (Vacuum Pump System for Manifold), Valves: K (Supply Valve; N.C., Release Valve; N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: N (w/o Pressure Sensor, Digital Pressure Switch for Vacuum), Connector: C1 (Common Wiring, Plug-in for Manifold), Vacuum, V Port: 06 (Metric Size, ø6 One-touch Fitting), Bracket: w/o Option, Pump System PE Port Female Thread: w/o Option, Individual Release
System: Q (Vacuum Pump System for Manifold), Valves: K (Supply Valve; N.C., Release Valve; N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: N (w/o Pressure Sensor, Digital Pressure Switch for Vacuum), Connector: C1 (Common Wiring, Plug-in for Manifold), Vacuum, V Port: 07 (Inch Size, ø1/4" One-touch Fitting), Bracket: w/o Option, Pump System PE Port Female Thread: w/o Option, Individual Release
System: Q (Vacuum Pump System for Manifold), Valves: K (Supply Valve; N.C., Release Valve; N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: P (Pressure Sensor, 0 to -101, Analog Output 1 to 5 V), Connector: C (Common Wiring, Plug-in for Manifold), Vacuum, V Port: 07 (Inch Size, ø1/4" One-touch Fitting), Bracket: w/o Option, Pump System PE Port Female Thread: w/o Option, Individual Release
System: Q (Vacuum Pump System for Manifold), Valves: K (Supply Valve; N.C., Release Valve; N.C.), Rated Voltage: 5 (24 VDC), Vacuum Sensor: C (Digital Pressure Switch for Vacuum, 0 to -101, PNP 2 Outputs), Connector: C1 (Common Wiring, Plug-in for Manifold), Vacuum, V Port: 07 (Inch Size, ø1/4" One-touch Fitting), Bracket: w/o Option, Pump System PE Port Female Thread: w/o Option, Individual
Supply: w/o Option, Vacuum Break Flow Adjustment: K (Vacuum Break Flow Adjustment Needle Screwdriver Operation Type)