SMC Corporation of America
Elite Part Number Search
Search Results "NCDQ8A300-150-A93"

For D-A93, only outward electrical entry (D dimension) is available. Dimensions in parentheses apply to 12-CXSJ10.

Tie-rod mount Reed switches 2 color indication With timer 2 color indication 2 color indication/water resistant 2 color indication/with diagnostic output Direct mount D-A93 D-G39/K39 D-F5/J5 D-F5NTL D-F5W/J59W D-F5BAL D-F5F D-F9N Band mount Tie-rod mount Solid state switches D-F9P Direct mount D-F9B Models D-A90, D-A93, D-F9N, D-F9P and D-F9B are exclusively for use with the lock unit

Mounting of auto switch Auto switch mounting screw (M2.5 x 0.45 x 8L) Tightening Torque of Auto Switch Mounting Screw [Nm] Auto switch Auto switch model Tightening torque Auto switch mounting nut D-M9(V) D-M9W(V) D-M9A(V) D-A93 Auto switch mounting screw (M3 x 0.5 x 8L) 0.05 to 0.15 Auto switch D-A9(V) (Excluding D-A93) 0.10 to 0.20 Auto switch fixing screw (M2.5 x 0.45 x 10L) Auto switch

Consult with SMC regarding water resistant types with the above model numbers. 2 1 m type lead wire is only applicable to D-A93. Solid state auto switches marked are produced upon receipt of order.

Note 4) ( ): Dimensions for D-A93. Specific Product Precautions Be sure to read this before handling. Mounting Caution Appropriate tightening torque 1. Observe the proper tightening torque in the right table in mounting.

Lead wire length (m) Auto switch model Electrical entry direction Load voltage Wiring (Output) Special function Electrical entry Indicator light Type 0.5 (Nil) 3 (L) Applicable load AC DC 12 V In-line A93 Reed auto switch 2-wire Grommet Yes Relay, PLC 100 V 24 V M9N 3-wire (NPN) 12 V Solid state auto switch Grommet Yes Relay, PLC 24 V M9B 2-wire 12 V Lead wire length symbols 0.5 mNil

Note 3) ( ) in column W denotes the dimensions of D-A93. Operating Range Bore size (mm) Auto switch model 6 10 16 20 5 6 9 11 D-F9W/F9WV D-M9/M9V D-A9/A9V 3 (2) 3.5 (2) 5.5 (3) 6.5 (3.5) Since this is a guideline including hysteresis, not meant to be guaranteed. (Assuming approximately 30% dispersion.)

Auto Switch Proper Mounting Position (Detection at Stroke End) Solid state auto switch D-M9 Reed auto switch D-A93 C B A Lead wire, in-line entry Values in the table below are used as a reference when mounting the auto switches for stroke end detection. For actually setting the auto switches, adjust them after confirming their operation.

Please consult with SMC regarding water resistant type with the above model numbers. 2 1 m type lead wire is only applicable to D-A93. Solid state auto switches marked with are produced upon receipt of order.

Lead wire length (m) Load voltage Auto switch model Electrical entry direction Wiring (Output) Special function Electrical entry Indicator light Style 0.5 (Nil) 3 (L) Applicable load AC DC 12V Horizontal 100V 24V Reed switch 2-wire Relay, PLC Grommet Yes A93 12V 3-wire (NPN) M9N 24V Solid state switch Relay, PLC Grommet Yes 12V 2-wire M9B Lead wire symbol 0.5mNil (Example) A93

Note 3) ( ) in column W is the dimensions of D-A93.

Note 3) ( ) in column W is the dimensions of D-A93.

Note 4) Figures in ( ) in the table W are D-A93.

This is a legacy product. Please contact us for the latest version.sales@ocaire.com, CYLINDER, ACTUATOR, NCQ8 COMPACT CYLINDER, JE, 1 1/16" NCQ8 DBL-ACT AUTO-SW, 1 lb

The series MGG guided cylinder is ideally suited for material handling applications involving stopping, lifting, and pushing. It combines the functions of a conventional cylinder, linear motion guide, and non-rotation device. Features include built-in shock absorbers, finite stroke adjustment, bumpers, and switch capability. Other features include: Slide or ball bushing bearings available

For long strokes with compact size and an integrated guide, the MY1 series rodless actuator provides an ideal solution. The MY1 mechanical joint rodless cylinder includes four standard models, which allow the appropriate bearing style to be selected in order to match the accuracy and load requirements of your application. If necessary, you can also combine the basic MY1 cylinder with an

CHQ CHK CHN Mounting correctly Mounting incorrectly CHM CHM CHS Solid state D-M9N, M9P, M9B, M9NV, M9PV, M9BV D-M9NW, M9PW, M9BW, M9NWV, M9PWV, M9BWV D-M9NA, M9PA, M9BA, M9NAV, M9PAV, M9BAV Reed D-A90, A93, A96, A90V, A93V, A96V CH2 Aporox. 10 to 15 CHA Figure 1.

Auto Switch Proper Mounting Position (Detection at Stroke End) D-A93 12 16 to 25 A B W A B W D-M9B/M9N 12 16 to 25 A B W A B W B D-A93 B D-M9B/M9N/M9P Bore size (mm) A 11.5 W 4 A 15.5 W 5.5 12 16 20 25 0.5 4.5 12 0 4.5 16 4 6 16 3.5 1 20 7.5 2.5 17 5.5 -1 21 9.5 0.5 Specific Product Precautions Be sure to read this before handling. Mounting Caution 1.

Load voltage Internal voltage drop (illuminated load current load when ON) range AC DC 24V or less 50mA Relay D-A90 AC DC 48V or less 40mA Not provided PLC D-A90V IC circuit AC DC 100V or less 20mA D-A93 2.4V or less (up to 20mA) 3V or less DC24V 5 to 40mA D-A93 Provided Relay (up to 40mA) D-A93V PLC D-A93V 2.7V or less AC100V 5 to 20mA 2.7V or less D-A96 D-A96V DC4 to 8V 20mA 0.8V or less

F A A Lr Lr = 200mm L X S 400 8 60 Table displacement (m) LXSH-150 Table displacement (m) Table displacement (m) 350 7 LXSH-150 LXSH-150 50 300 6 LXSH-125 LXSH-125 250 5 40 LXSH-125 LXSH-100 LXSH-100 200 4 30 LXSH-75 LXSH-100 LXSH-75 3 150 20 LXSH-50 LXSH-75 2 100 LXSH-50 LXSH-50 10 1 50 0 0 0 1 2 3 4 5 6 8 9 10 10 10 7 1 2 3 4 5 6 8 9 7 1 2 3 4 5 6 8 9 7 Weight (kg) Weight (kg) Weight (kg