Rated Flow Range: 2 to 200 L/min, Flow Adjustment Valve: None (Straight), Port Size: ø8, Output Specification: Out 1: PNP; Out 2: Analog 1 to 5 V - Analog 0 to 10 V, Lead Wire: Lead Wire w/Connector, Unit Specification: SI Unit Only, Bracket/Panel Mount Adapter: Bracket, w/o Flow Adjustment Valve, Calibration Certificate: Calibration Certificate, Made to Order: -
Rated Flow Range: 2 to 200 L/min, Flow Adjustment Valve: None (Straight), Port Size: ø8, Output Specification: Out 1: IO-Link or NPN/PNP, Out 2: Analog 4 to 20 mA, Lead Wire: w/M12 Conversion Lead Wire and Connector, 0.1m, Unit Specification: Unit Selection Function, Bracket/Panel Mount Adapter: Bracket, w/o Flow Adjustment Valve, Calibration Certificate: -, Made to Order: -
Rated Flow Range: 2 to 200 L/min, Flow Adjustment Valve: None (Straight), Port Size: NPT1/4, Output Specification: Out 1: PNP; Out 2: Analog 1 to 5 V - Analog 0 to 10 V, Lead Wire: Lead Wire w/Connector, Unit Specification: SI Unit Only, Bracket/Panel Mount Adapter: -, Calibration Certificate: -, Made to Order: -
Rated Flow Range: 2 to 200 L/min, Flow Adjustment Valve: None (Straight), Port Size: ø8, Output Specification: Out 1: PNP; Out 2: PNP, Lead Wire: Lead Wire w/Connector, Unit Specification: Unit Selection Function, Bracket/Panel Mount Adapter: Panel Mount Adapter, w/o Flow Adjustment Valve, Calibration Certificate: -, Made to Order: -
Rated Flow Range: 2 to 200 L/min, Flow Adjustment Valve: None (Straight), Port Size: NPT1/4, Output Specification: Out 1: NPN; Out 2: NPN, Lead Wire: Lead Wire w/Connector + Rubber Cover for Connector, Unit Specification: Unit Selection Function, Bracket/Panel Mount Adapter: Bracket, w/o Flow Adjustment Valve, Calibration Certificate: -, Made to Order: -
Rated Flow Range: 2 to 200 L/min, Flow Adjustment Valve: None (Straight), Port Size: ø8, Output Specification: Out 1: PNP; Out 2: PNP, Lead Wire: Lead Wire w/Connector, Unit Specification: SI Unit Only, Bracket/Panel Mount Adapter: -, Calibration Certificate: -, Made to Order: -
Rated Flow Range: 2 to 200 L/min, Flow Adjustment Valve: None (Straight), Port Size: NPT1/4, Output Specification: Out 1: PNP; Out 2: PNP, Lead Wire: Lead Wire w/Connector, Unit Specification: Unit Selection Function, Bracket/Panel Mount Adapter: Bracket, w/o Flow Adjustment Valve, Calibration Certificate: -, Made to Order: -
Rated Flow Range: 2 to 200 L/min, Flow Adjustment Valve: None (Straight), Port Size: NPT1/4, Output Specification: Out 1: PNP; Out 2: Analog 4 to 20 mA, Lead Wire: Lead Wire w/Connector, Unit Specification: SI Unit Only, Bracket/Panel Mount Adapter: -, Calibration Certificate: -, Made to Order: -
Rated Flow Range: 2 to 200 L/min, Flow Adjustment Valve: None (Straight), Port Size: ø8, Output Specification: Out 1: NPN; Out 2: Analog 4 to 20 mA, Lead Wire: Lead Wire w/Connector, Unit Specification: Unit Selection Function, Bracket/Panel Mount Adapter: Bracket, w/o Flow Adjustment Valve, Calibration Certificate: -, Made to Order: -
Rated Flow Range: 2 to 200 L/min, Flow Adjustment Valve: None (Straight), Port Size: ø8, Output Specification: Out 1: PNP; Out 2: PNP, Lead Wire: Lead Wire w/Connector, Unit Specification: Unit Selection Function, Bracket/Panel Mount Adapter: Bracket, w/o Flow Adjustment Valve, Calibration Certificate: -, Made to Order: -
Rated Flow Range: 2 to 200 L/min, Flow Adjustment Valve: None (Straight), Port Size: NPT1/4, Output Specification: Out 1: PNP; Out 2: Analog 4 to 20 mA, Lead Wire: Lead Wire w/Connector + Rubber Cover for Connector, Unit Specification: Unit Selection Function, Bracket/Panel Mount Adapter: Bracket, w/o Flow Adjustment Valve, Calibration Certificate: Calibration Certificate, Made to Order:
Rated Flow Range: 2 to 200 L/min, Flow Adjustment Valve: None (Straight), Port Size: 1/4, Output Specification: Out 1: NPN; Out 2: Analog 4 to 20 mA, Lead Wire: w/o Lead Wire w/Connector, Unit Specification: SI Unit Only, Bracket/Panel Mount Adapter: -, Calibration Certificate: -, Made to Order: -
Rated Flow Range: 2 to 200 L/min, Flow Adjustment Valve: None (Straight), Port Size: NPT1/4, Output Specification: Out 1: PNP; Out 2: Analog 4 to 20 mA, Lead Wire: Lead Wire w/Connector + Rubber Cover for Connector, Unit Specification: Unit Selection Function, Bracket/Panel Mount Adapter: No Bracket, Calibration Certificate: Calibration Certificate, Made to Order: -
Rated Flow Range: 21 (2 to 200 L/min), Flow Adjustment Valve: None (Straight), Port Size: C8 (ø8), Output Specification: E (Out 1: PNP; Out 2: Analog 1 to 5 V - Analog 0 to 10 V), Lead Wire: Lead Wire w/Connector, Unit Specification: M (SI Unit Only), Bracket/Panel Mount Adapter: No Bracket, Calibration Certificate: A (Calibration Certificate)
Rated Flow Range: 21 (2 to 200 L/min), Flow Adjustment Valve: None (Straight), Port Size: C8 (ø8), Output Specification: C (Out 1: NPN; Out 2: Analog 1 to 5 V - Analog 0 to 10 V), Lead Wire: Lead Wire w/Connector, Unit Specification: Unit Selection Function, Bracket/Panel Mount Adapter: No Bracket, Calibration Certificate: A (Calibration Certificate)
Rated Flow Range: 21 (2 to 200 L/min), Flow Adjustment Valve: None (Straight), Port Size: C8 (ø8), Output Specification: C (Out 1: NPN; Out 2: Analog 1 to 5 V - Analog 0 to 10 V), Lead Wire: Lead Wire w/Connector, Unit Specification: Unit Selection Function, Bracket/Panel Mount Adapter: R (Bracket, w/o Flow Adjustment Valve), Calibration Certificate: A (Calibration Certificate)
DIGITAL FLOW SWITCH, DIGITAL FLOW SWITCH, F27, 221 lb
Digital Flow Switch, DIGITAL FLOW SWITCH, F27, 107 lb
DIGITAL FLOW SWITCH, DIGITAL FLOW SWITCH, F27, 197 lb
Digital Flow Switch, DIGITAL FLOW SWITCH, F27, 72.00000 lb