M-8 M-12 SMC Type of 2-Apr-01 SMC Quick Reference Auto Switch Chart with (PnP) M-8 (3 pin) & M-12 (4 pin) Connectors, Page 1/2 The above older MDB1 Direct Body Mount 32, 40, 50, 63, 80 & 100 Bore sizes (Auto Switch Spacer # BMP1-032 required) our new part # MHL, Direct Body Mount 10, 16, 20, 25, 32 & 40 Gripper Bore sizes -Y7PSDPC MHQG2 Direct Body Mount 32 & 40 Gripper Bore sizes MHS2/3/
Ejector stations Port & silencer position 1 station 01 Right side Left side Both sides R L S 10 stations (Max.) 10 Note) Left and right as viewed with the VAC port in front Thread type Common exhaust port size 1/2 3/4 ZZMA dedicated silencer (ZZM-SA) 04 06 S Rc NPTF G Nil T F When placing an order, include the single type ejector models to be manifolded together with the manifold part
.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Nozzle diameter C C CN Lead wire length 0.6 m Lead wire length 3 m No lead wire 05 0.5 mm 07 0.7 mm 10 1.0 mm 13 1.3 mm 15 1.5 mm ZL Refer to Table (2) for lead wire with 4-wire connecor.
Tube Size Packaging Table 01 03 05 07 09 11 13 15 19 1/8 5/32 3/16 1/4 5/16 3/8 1/2 5/8 3/4 Tube Size Type A (Monowall) Type B (Reinforced) TIV01 TIV03 TIV05 TIV07 TIV09 TIV11 TIV13 TIV15 TIV19 3/4 1/8 5/32 3/16 1/4 5/16 3/8 1/2 5/8 33 77 153 305 33 77 153 305 33 77 153 305 33 77 153 305 33 77 153 305 33 77 153 305 33 77 153 305 33 77 153 305 33 77 153 305 Length (Meters) S S S S S S S S
Note) Inch size Metric size KE 23 01 1 8" 3.2 4 6 8 10 12 5 32" Control type 04 06 08 10 12 03 05 07 09 11 13 3 16" Meter-out Meter-in 0 1 AS-FG 1 4" 5 16" AS-FP 3 8" 1 2" With One-touch fitting AS-FM Note) For applicable tubing O.D. selection, refer to the Model on page 630. Use 1/8" tube.
Note) Metric size 23 04 06 08 10 12 Inch size 3.2 01 03 05 07 09 11 13 1/8" 5/32" 3/16" 1/4" 5/16" 3/8" 1/2" 4 6 8 10 12 Made to Order (For details, refer to page 622.)
Available in standalone or manifold configurations.Vacuum ejector, Stations: 01, 02, 03, 04, 05, 06, 07, 08, Right, left, or both side vacuum supply, "Manifold, VACUUM EJECTOR
Available in standalone or manifold configurations.Vacuum ejector, Stations: 01, 02, 03, 04, 05, 06, 07, 08, Right, left, or both side vacuum supply, MANFD VAC GENERATOR, VACUUM SERIES, ZZX1 MANIFOLD UNIT, JC, ZZX1 1/8 PORTED, .77686 lb
NZX is available in standalone or manifold configurations.Vacuum ejector, Stations: 01, 02, 03, 04, 05, 06, 07, 08, Right, left, or both side vacuum supply, ZZX1 MANIFOLD UNIT, VACUUM EJECTOR
Available in standalone or manifold configurations.Vacuum ejector, Stations: 01, 02, 03, 04, 05, 06, 07, 08, Right, left, or both side vacuum supply, ZZX1 1/8 PORTED, VACUUM SERIES, ZZX1 MANIFOLD UNIT, JC, ZZX1 1/8 PORTED, 0.88267 lb
NZX is available in standalone or manifold configurations.Vacuum ejector, Stations: 01, 02, 03, 04, 05, 06, 07, 08, Right, left, or both side vacuum supply, MANIFOLD, NZX 2-STA, VACUUM SERIES, ZZX1 MANIFOLD UNIT, JD, ZZX1 1/8 PORTED, .35200 lb
NZX is available in standalone or manifold configurations.Vacuum ejector, Stations: 01, 02, 03, 04, 05, 06, 07, 08, Right, left, or both side vacuum supply, MANIFOLD ASSY, 7-STA, VACUUM SERIES, ZZX1 MANIFOLD UNIT, JD, ZZX1 1/8 PORTED, .84480 lb
NZX is available in standalone or manifold configurations.Vacuum ejector, Stations: 01, 02, 03, 04, 05, 06, 07, 08, Right, left, or both side vacuum supply, MANIFOLD ASSY, 5-STA, VACUUM SERIES, ZZX1 MANIFOLD UNIT, JD, ZZX1 1/8 PORTED, 0.6512 lb
NZX is available in standalone or manifold configurations.Vacuum ejector, Stations: 01, 02, 03, 04, 05, 06, 07, 08, Right, left, or both side vacuum supply, MANIFOLD, VACUUM SERIES, ZZX1 MANIFOLD UNIT, JD, ZZX1 1/8 PORTED, .54780 lb
NZX is available in standalone or manifold configurations.Vacuum ejector, Stations: 01, 02, 03, 04, 05, 06, 07, 08, Right, left, or both side vacuum supply, MANIFOLD ASSY, 8-STA, VACUUM SERIES, ZZX1 MANIFOLD UNIT, JD, ZZX1 1/8 PORTED, 0.836 lb
Rated Flow Range: 05 (0.05 to 5 L/min), Flow Adjustment Valve: None (Straight), Port Size: 01 (Rc1/8), Output Specification: L3 (Out 1: IO-Link or NPN/PNP, Out 2: Analog 1-5V), Lead Wire: W (Lead Wire w/Connector + Rubber Cover for Connector), Unit Specification: Unit Selection Function, Bracket/Panel Mount Adapter: R (Bracket, w/o Flow Adjustment Valve), Calibration Certificate: A (Calibration
Rated Flow Range: 05 (0.05 to 5 L/min), Flow Adjustment Valve: None (Straight), Port Size: 01 (Rc1/8), Output Specification: F (Out 1: PNP; Out 2: Analog 4 to 20 mA), Lead Wire: W (Lead Wire w/Connector + Rubber Cover for Connector), Unit Specification: Unit Selection Function, Bracket/Panel Mount Adapter: R (Bracket, w/o Flow Adjustment Valve), Calibration Certificate: A (Calibration Certificate
Rated Flow Range: 05 (0.05 to 5 L/min), Flow Adjustment Valve: None (Straight), Port Size: 01 (Rc1/8), Output Specification: B (Out 1: PNP; Out 2: PNP), Lead Wire: N (w/o Lead Wire w/Connector)
Rated Flow Range: 05 (0.05 to 5 L/min), Flow Adjustment Valve: None (Straight), Port Size: 01 (Rc1/8), Output Specification: A (Out 1: NPN; Out 2: NPN)
Rated Flow Range: 05 (0.05 to 5 L/min), Flow Adjustment Valve: None (Straight), Port Size: 01 (Rc1/8), Output Specification: B (Out 1: PNP; Out 2: PNP)