1/8 M5 x 0.8 depth 5 Piping port 2 x 3.5 Mounting hole T1: NPTF 1/8 01: R 1/8 13 13 777
F (LC6D-2 only) +24V GND CW+ CW CCW+ CCW PD+ PD A B C D E 7 6 3 10 CW CW 10 10 2 R 330 CCW input 330 CCW input 2 2 9 1 CCW CCW 8 9 9 5 4 14 13 12 R 330 PD input 1 PD 8 11 F Functions Function change-over switch Input signal terminal CW pulse input terminal By applying the pulse input, the actuator moves from the motor side to the end side.
(Example) 23-R Semi-standard Combinations Available Not available Accessory, Semi-standard Option Symbol 1 1S-1 1S-2 2 3 6 8 R -1 -1S-1 -1S-2 -2 -3 -6 -8 -R 1000 cm3 tank 1000 cm3 (With switch) Bottom limit ON 1000 cm3 (With switch) Bottom limit OFF Metal bowl Lubricator with drain cock Nylon bowl Metal bowl with level gauge Flow direction: Right to left Note) -1, -1S-1 and -1S-2 are with
Motorless Type Electric Actuator/Slider Type Ball Screw Drive LEFS Series LEFS25, 32, 40 How to Order LEFS 100 A 25 q e y NZ w r t H R q Accuracy r Motor type e Motor mounting position y Stroke [mm] t Lead [mm] Nil Basic type H High precision type 50 50 to to 1200 1200 Nil In-line R Right side parallel L Left side parallel Symbol LEFS25 LEFS32 LEFS40 H 20 24 30 A 12 16 20 B 6 8 10 Symbol
How to Order 6N 1 1 D B 25 50 LEY X5 R o Made to Order: Dust-tight/ Water-jet-proof q w e r t y u i !0 !1 !2 !
Rc 1/8 R, Rc 1/4 R, Rc 3/8 R, Rc 1/2 R, Rc 3/4 Symbol M5 01 02 03 04 06 Symbol 23 04 06 08 10 12 16 Symbol 50 60 65 80 85 110 Applicable tubing O.D. mm 3.2 4 6 8 10 12 16 Applicable hose I.D.
M M5 M5 x 0.8 01 02 03 04 00 04 06 08 10 12 R 1/8 R 1/4 R 3/8 R 1/2 Thread connection H/DL L/LL KC Applicable tubing O.D. Same dia. tubing 4 6 8 10 12 04 06 08 10 12 4 6 8 10 12 KK Tubing (rod) connection Different dia. tubing (plug-in reducer) KK130 DM Construction KDM KB KR KA KQG2 KG KFG2 MS KKA M5 type Male connector KP KP Description Material Component Parts LQ No.
1.3 x 108 1.3 x 109 B w, e 1.3 x 108 1.3 x 109 C r 1.3 x 1010 (FKM) 1.3 x 109 D w 1.3 x 108 1.3 x 1011 (FKM) E w, r 1.3 x 108 1.3 x 109 Sealmaterial Symbol Seal material Compound no.
For details, refer to 6.13 P r o d u c t I n f o r m a t i o n Display. (2) Related Parameter Set the following parameter to use backlash compensation. Backlash Compensation Direction Set the direction in which to apply backlash compensation. Parameter Function When Enabled Classification n. 0 [Factory setting] Compensates with a reference in the forward direction.
For details, refer to 6.13 P r o d u c t I n f o r m a t i o n Display. (2) Related Parameter Set the following parameter to use backlash compensation. Backlash Compensation Direction Set the direction in which to apply backlash compensation. Parameter Function When Enabled Classification n. 0 [Factory setting] Compensates with a reference in the forward direction.
FA 3m 27 (M230) 2 O 1 No.ZB-OM00301 Assy ZB1ZS A M G A E 0.0~-101.0KPa G (2m) F -100.0~100KPa ZS-39-5G A NPN2 B PNP2 1) M SI2) P (psi)1) 1) (M230) 2 2)kPa O 1 V Assy 45 2 V Assy 45 (V Assy ) A ) 28 - No.ZB-OM00301 A R R Nm 0.0540.08 R R ON OFF R 29 - No.ZB-OM00301 3 P911 Nm 0.075~0.096 M2 / 3 Assy Assy / / O (/) O 30 - No.ZB-OM00301 [L/min(ANR)] V
.: AMX-OMX0018-B PRODUCT NAME Line filter MODEL / Series / Product Number AFF20-(F, N)01 ~ (F, N)02(B, C)(-2, 6, C, J, L, R, Z)-D AFF30-(F, N)02 ~ (F, N)03(B, C, D)(-2, 6, 8, J, L, R, W, Z)-D AFF40-(F, N)02 ~ (F, N)04(B, C, D)(-2, 6, 8, J, L, R, W, Z)-D Contents Page 1. Safety Instructions 2 to 7 2. Application 8 3. Standard specifications 8 4. How to order 9 5.
.: AMX-OMX0019-C PRODUCT NAME Mist Separator MODEL / Series / Product Number AM20-(F, N)01 ~ (F, N)02(B, C)(-2, 6, C, J, L, R, Z)-D AM30-(F, N)02 ~ (F, N)03(B, C, D)(-2, 6, 8, J, L, R, W, Z)-D AM40-(F, N)02 ~ (F, N)04(B, C, D)(-2, 6, 8, J, L, R, W, Z)-D Contents Page 1. Safety Instructions 2 to 7 2. Application 8 3. Standard specifications 8 4. How to order 9 5.
.: AMX-OMX0020-B PRODUCT NAME Micro Mist Separator MODEL / Series / Product Number AM20-(F, N)01 ~ (F, N)02(B, C)(-2, 6, C, J, L, R, Z)-D AM30-(F, N)02 ~ (F, N)03(B, C, D)(-2, 6, 8, J, L, R, W, Z)-D AM40-(F, N)02 ~ (F, N)04(B, C, D)(-2, 6, 8, J, L, R, W, Z)-D Contents Page 1. Safety Instructions 2 to 7 2. Application 8 3. Standard specifications 8 4. How to order 9 5.
AMX-OMY0038-A PRODUCT NAME Activated Carbon Filter MODEL / Series / Product Number AMK20-(F, N)01 ~ (F, N)02(B)(-2, 6, C, R, Z)-D AMK30-(F, N)02 ~ (F, N)03(B)(-2, 6, R, Z)-D AMK40-(F, N)02 ~ (F, N)04(B)(-2, 6, R, Z)-D Contents Page 1. Safety Instructions 2 to 7 2. Application 8 3. Standard specifications 8 4. How to order 9 5. Construction / Options / Replacement parts 10 6.
Leakage voltage Take note that the leakage voltage will increase when a resistor is used in parallel with switching element or a C-R circuit (surge voltage suppressor) is used for protecting a switching device because of the passing leakage voltage through the C-R circuit. The suppressor residual leakage voltage should be as follows. Should be3% or less of rated voltage.
-2VT307N-OMV0001 / *3) 1 1.5 *3)1 1 () [] -3VT307N-OMV0001 VT307 3 / / () () ( ) () C-R ( ) C-R DC 3% , () ( AC 15% ) (SSR)AC 1) (C-R ) OFF 2)() 1V ,-10 1 DC N.O.() 3 4 No.VT307N-OMV0001 VT307 3 / () DC 30N 1) 2)1 ()ISO VG32 (SDS) 1 Nm Rc 1/8 35 Rc 1/4 812 5 No.VT307N-OMV0001 VT307 3 / () () 30 ( ) , 1 ()ISO VG32 6 No.VT307N-OMV0001 VT307 Series/ DIN 1) ()
( ) C-R DC 2% AC 15% (SSR (SSR (SSR (SSR ) ) ) ) AC AC AC AC 1 (C-R ) OFF 2)() 1V -10 () () ( ( ( ( ) ) ) ) () 1 DC N.O.() 3 () 4 VT325-OMT0001 VT325 Ser VT325 Ser VT325 Ser VT325 Series ies ies ies 3 3 3 3 / / / / ( ( ( ( ) ) ) ) DC 1 ()ISO VG32 (MSDS) 1 Rc Rc Rc Rc 1 Nm Rc 1/4 12 14 Rc 3/8 22 24 5 VT325-OMT0001 VT325 Series VT325 Series VT325 Series VT325 Series 3 3 3
JIS B 8370: JIS B 8361: JIS B 9960-1: 1 ) JIS B 8433-1993: *2) 1. 2. 3. 1. 2. 3. 4. 2 VT315**-OMH0005-A / / / / 1 1 1 1 1.5 1.5 1.5 1.5 *3) *3) *3) *3) * * * *3) 3) 3) 3) 1 1 1 1 1 1 1 1 () 3 VT315**-OMH0005-A VT315 Series VT315 Series VT315 Series VT315 Series 3 3 3 3 / / / / / / / / 3 () C-R ( )C-R DC 5% () () () ( ( ( ( ) ) ) ) () AC 15% (SSR (SSR (SSR (SSR ) ) ) ) AC AC AC