25 M For positive pressure ZSE30 01 25 M For vacuum/Low pressure Option 2 Piping specification R 1/8 (with M5 female thread) NPT 1/8 (with M5 female thread) 01 T1 None Bracket Nil A Output specification NPN output PNP output 1 to 5V output 4 to 20mA output 25 65 26 28 Panel mount B Unit specification Nil M With unit switching function Fixed SI unitI (International System of Units) Note)
High Filtration (0.3 m) Space-saving and easy piping. (For further information, Refer to Best Pneumatics Vol. 16.)
SERIES 15 FLOW CHARTS 400 400 1/32 1/32 3/64 3/64 1/16 1/16 3/32 3/32 1/8 1/8 ORIFICE-INCH ORIFICE-INCH 100 100 50 50 PRESSURE PRESSURE DROP ROP PSI PSI 10 10 5 01 01 02 02 05 05 1 2 5 WATER FLOW-GPM SERIES 50 FLOW CHARTS COAST PNEUMATICS 8055 E.
Cannot be used with M: Round pressure gauge (with color zone). Available by request for special.
CEP: 09950-350, Brasil TEL: 11-4051-1177 FAX: 11-4071-6636 GREECE (Distributor) S.Parianopoulos S.A. 7, Konstantinoupoleos Street 11855 Athens, Greece TEL: 01-3426076 FAX: 01-3455578 DENMARK SMC Pneumatik A/S Knudsminde 4 B DK-8300 Odder, Denmark TEL: 70252900 FAX: 70252901 COLOMBIA (Distributor) Airmatic Ltda. Calle 18 69-05 Apart.
Example: In case of 6 stations of air suction filter ZFA100-01 ZZFA1-06 1 pc. (Brackets for 6 stations) ZFA100-01 6 pcs.
LP-01 ML1C LC-01 25 32 40 Series Mounting position A B ML1C 177.5 128.5 152.5 123.5 147.5 172.5 D-M5 D-M5W D-M5T Lead wire cap Lead wire clamp Auto switch 14 11 Lead Wire Clamp/Lead Wire Cap (Option) 22 22 B A Lead wire clamp Lead wire cap Series LC-01 LP-01 ML1C (mm) 25 32 40 Mounting position Series A B 124.8 148.8 173.8 ML1C 113.2 137.2 162.2 Minimum Stroke for Auto Switch Mounting Operating
Knuckle pin (Common with double clevis pin) Rod end nut d d Dd9 C m L m l t t H B Metric Threads Metric Threads Bore size (mm) Bore size (mm) Snap ring d H B C t Dd9 l m Part No. Part No.
port) 2 x 18 (R1, R2 port) 1764 Series VFA3000 5 Port Air Operated Valve Dimensions: Body Ported 2 position double: VFA3230-01 02 2 x 18 (Pilot port) 2 x 4.3 (Mounting hole for manifold) Max. 3 Max. 3 2 x 4.2 (Mounting hole) 3 x , 14 18 (P , A, B port) 2-3 (Breathing port) 2 x 3 2 x 18 (R1, R2 port) SYA 3 position closed center/exhaust center/pressure center: VFA3 30-X1 3 4 5 01 02 SYJA
Note 3) Bowl assembly for AF30 to 60 models comes with a bowl guard (steel band material). 26 AF10 to 60 Dimensions L AF10, 20 AF50, 60 A G D Bracket (Option) L Bracket (Option) F D M G K K F M J J B E E B H OUT IN C OUT IN H C Port size OUT OUT Port size o s AF10: 25 AF20: 40 Drain A P Min. clearance for maintenance AF30, 40, 40-06 L Bracket (Option) A D G F M K J B E Drain Min. clearance
Optional Parts Clean Room Compliant (10-) 10-ARP20(K) 10-ARP30(K) 10-ARP40(K) Model Bracket assembly Note 1) ARP20P-270AS ARP30P-270AS ARP40P-270AS Set nut ARP20P-260S ARP30P-260S ARP40P-260S G49-4-01 G49-4-02 0.4 MPa G49-2-01 G49-2-02 0.2 MPa Round type Note 2) G49-7-01 G49-7-02 0.7 MPa Pressure gauge NPN output / Wiring bottom entry ISE35-N-25-MLA [ISE35-N-25-M (Switch body only)] NPN output
Optional Parts Clean Room Compliant (10-) 10-ARP20(K) 10-ARP30(K) 10-ARP40(K) Model Bracket assembly Note 1) ARP20P-270AS ARP30P-270AS ARP40P-270AS Set nut ARP20P-260S ARP30P-260S ARP40P-260S G49-4-01 G49-4-02 0.4 MPa G49-2-01 G49-2-02 0.2 MPa Round type Note 2) G49-7-01 G49-7-02 0.7 MPa Pressure gauge NPN output / Wiring bottom entry ISE35-N-25-MLA [ISE35-N-25-M (Switch body only)] NPN output
only)] G36-7-01 G46-7-02 Round type Note 2) 0.7 MPa Pressure gauge Square embedded type Note 3) GC3-7AS [GC3P-010AS (Pressure gauge cover only)] ISE35-N-25-MLA [ISE35-N-25-M (Switch body only)] NPN output / Wiring bottom entry ISE35-R-25-MLA [ISE35-R-25-M (Switch body only)] NPN output / Wiring top entry Note 4) Digital type ISE35-N-65-MLA [ISE35-N-65-M (Switch body only)] PNP output / Wiring
only)] G36-7-01 G46-7-02 Round type Note 2) 0.7 MPa Pressure gauge Square embedded type Note 3) GC3-7AS [GC3P-010AS (Pressure gauge cover only)] ISE35-N-25-MLA [ISE35-N-25-M (Switch body only)] NPN output / Wiring bottom entry ISE35-R-25-MLA [ISE35-R-25-M (Switch body only)] NPN output / Wiring top entry Note 4) Digital type ISE35-N-65-MLA [ISE35-N-65-M (Switch body only)] PNP output / Wiring
Lead Wire Clamp/Lead Wire Cap (Option) CNS Series Lead wire clamp LC-01 Lead wire cap LP-01 ML1C CLS Lead Wire Clamp/Lead Wire Cap (Option) (mm) CLQ 25 32 40 Mounting position Series Series Lead wire clamp Lead wire cap A 124.8 148.8 173.8 LP-01 ML1C LC-01 ML1C MLGP B 113.2 137.2 162.2 25 32 40 Series Mounting position RLQ ML1C 177.5 A 128.5 152.5 B 123.5 147.5 172.5 MLU Operating Range Minimum
Grommet: G Conduit: C Approx. 300 Approx. 280 D D Q F Q F C C G (PF) 1/2 R R E E A H 2-P Port size 2-M B B A H 2-P Port size 2-M L L K K DIN connector: D Conduit terminal: T Cable 6.8 to 10 27.5 F F Q (Q) S 34 25 U R C R C (44) G (PF) 1/2 E B A H D 2-P Port size (S) E G (PF) 1/2 B A H D 2-M 2-P Port size 2-M L L K K N.C.
Grommet: G Conduit: C Approx. 300 Approx. 280 D D Q F Q F C C G (PF) 1/2 R R E E A H 2-P Port size 2-M B B A H 2-P Port size 2-M L L K K DIN connector: D Conduit terminal: T Cable 6.8 to 10 27.5 F F Q (Q) S 34 25 U R C R C (44) G (PF) 1/2 E B A H D 2-P Port size (S) E G (PF) 1/2 B A H D 2-M 2-P Port size 2-M L L K K N.C.
Lead Wire Clamp/Lead Wire Cap (Option) CNS Series Lead wire clamp LC-01 Lead wire cap LP-01 ML1C CLS Lead Wire Clamp/Lead Wire Cap (Option) (mm) CLQ 25 32 40 Mounting position Series Series Lead wire clamp Lead wire cap A 124.8 148.8 173.8 LP-01 ML1C LC-01 ML1C MLGP B 113.2 137.2 162.2 25 32 40 Series Mounting position RLQ ML1C 177.5 A 128.5 152.5 B 123.5 147.5 172.5 MLU Operating Range Minimum
AK Applicable tubing O.D. d L2 L3 M Inch size ASS ASR D2 L1 ASF T2 L4 H1 H1 (Hexagon width across flats) (Hexagon width across flats) H2 H2 (He (Hexagon width across flats) xagon width across flats) (Hexagon width across flats) D3 A1 L5 D1 A2 T1 Inch Size L4 Weight (g) d T1 D1 A2 A1 D3 M L3 L2 L1 H1 H2 D2 Max. Min.
Withstand pressure V, 1 minute, AC 1000 Special wiring specifications (options) Insulation resistance M/km, 20C 5 or more Note) The minimum bending radius for D-sub connector cables is 20mm. (For 25P) Mixed single and double wiring are available as options. The maximum number of manifold stations is determined by the number of solenoids.