Inset the signal cable through the hole and fit the nipple A, nipple B and lock nut. Then fit the cap A, cap B and rubber bushing. Recommended cable diameter: 6 to 13 mm Signal cable entry For option B Signal cable entry Lock nut Nipple A Rubber bush Nipple B Cap B Cap A Fig. 3-9 Mounting to the cable gland Fit the nipple A and nipple B closely until it clicks.
Table b.2 Condition that the file can be loaded The caution screen, when the file cannot be loaded.
VFR VP450 VP470 VP4 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com 82 (3 position: 98.5) 129 VZS 71(95.5) VFS 139.5 B A B A VS4 VQ7 (External pilot port) 1/8 (External pilot port) 1/8 EVS VFN A B B A B B B A EA P EB P EA EB ( ): Port size 3/4, 1 Dimensions: Port
x 103 M Yaw moment M3 = m x g x (L + A) x 103 M Roll moment M2 = m x g x (L + B) x 103 (mm) Model CYP15 CYP32 A 16.5 27.0 B 25.5 48.0 L B L B L A M1, 2, 3 : Moment [Nm] m : Load mass [kg] L : Distance to load center of gravity [mm] A, B : Distance to guide shaft [mm] g : Gravitational acceleration [9.8m/s] M2 M1 M3 m x g m x g Guide shaft mounting surface m x g Guide central axis Cylinder
x 103 M Yaw moment M3 = m x g x (L + A) x 103 M Roll moment M2 = m x g x (L + B) x 103 (mm) Model CYP15 CYP32 A 16.5 27.0 B 25.5 48.0 L B L B L A M1, 2, 3 : Moment [Nm] m : Load mass [kg] L : Distance to load center of gravity [mm] A, B : Distance to guide shaft [mm] g : Gravitational acceleration [9.8m/s] M2 M1 M3 m x g m x g Guide shaft mounting surface m x g Guide central axis Cylinder
06 10 14 B 3 4 1B 1 8 N.C. auto-drain N.O. auto-drain Drain guide Accessory 02 03 B 1 4 B 3 8 04 B 1 2 1 B 1 2 20 2B 1 4 B IN-OUT reversal direction T Element service indicator Option AMD800 to AMD1000 Self-standing type AMD801/901 Piping support type 20 01 AMD 8 20 00 AMD 8 Port size Body size Port size Body size 8 8 20 2B flange 30 3B flange 20 2B flange 30 3B flange 9 9 10 40 4B flange
(ASME B40.1 Grade B or better) psig/bar 4) (No code) Accuracy Cleanliness No oil ASME B40.1 level IV No oil Brass Polycarbonate Brass Phosphor bronze B Case Window Socket Bourdon tube Material MPa MPA 1.14 (29) 2.28 (58) 2.1 (53.5) 2.12 (54) NPT 1/4 0.42 (10.5) inch (mm) 3) Part number of pressure gauge itself.
Male thread nozzle High efficiency nozzle 600 400 KN-R02-250 KNH-R02-200 350 Flow rate [l/min (ANR)] Flow rate [l/min (ANR)] 500 300 400 KN-R02-200 250 KNH-R02-150 200 300 KN-R02-150 150 200 KNH-R02-100 100 KN-R02-100 100 50 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1 Supply pressure [MPa] Supply pressure [MPa] Low noise nozzle with male thread Copper extension
x 103 Yaw moment M3 = m x g x (L + A) x 103 Roll moment M2 = m x g x (L + B) x 103 (mm) Model CYP15 CYP32 A 16.5 27.0 B 25.5 48.0 L B L B L A M1, 2, 3 : Moment [Nm] m : Load mass [kg] L : Distance to load center of gravity [mm] A, B : Distance to guide shaft [mm] g : Gravitational acceleration [9.8m/s] M2 M1 M3 m x g m x g Guide shaft mounting surface m x g Guide central axis Cylinder
A B Easy manual unlocking Locked Unlocked Locking direction can be selected. Extension lock B A W Retraction lock W A B Various mounting brackets to accommodate wide range of applications.
(B contact) 3-2-3. Wiring of the AC adapter Make sure to ground the F.G. cable (green) with a resistance of 100 ohms or less. F.G. cable is the standard electric potential for static electricity neutralization. If the F.G. cable is not grounded properly, an optimal offset voltage (ion balance) cannot be obtained, and it may damage this product and connected power supply.
0.31 0.26 0.27/0.33 0.29/0.41 0.35 0.42 0.36/0.34 0.29/0.30 0.29 0.23 0.18/0.23 0.19/0.18 b 0.34 0.27 0.31/0.30 0.31/0.25 0.41 0.43 0.36/0.41 0.41/0.42 0.36 0.25 0.27/0.27 0.26/0.28 b 0.47 0.40 0.38/0.40 0.57/0.21 0.34 0.36 0.30/0.26 0.17/0.14 0.31 0.22 0.25/0.24 0.24/0.23 b 0.38 0.28 0.37/0.37 0.25/0.23 0.42 0.43 0.35/0.32 0.22/0.21 0.36 0.29 0.25/0.24 0.22/0.24 VP342 (Body ported) 1/8 1
4 2 6 10 8 14 12 16 34 20 18 24 22 26 30 28 32 36 40 38 Input/output connector (CS0) 3 1 5 9 7 13 11 15 19 17 23 21 33 25 29 27 31 35 39 37 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 Power supply terminal block 108 109 110 111 112 113 114 115 100 101 102 103 104 105 106 107 2 6 4 8 10 12 14 16 18 20 Input/output connector (CS1) 1 5 3 7 11 9 15 13 17 19 Green Red F E D C B A 9 8 7 6 5 4 3 2 1
E For vacuum 0 to -101 kPa 0 -101 kPa 10.1 kPa For compound -100 kPa to 100 kPa -100 kPa 100 kPa For low pressure 0 to 100 kPa 0 100 kPa -10 kPa 0 to 1 MPa 0 1 MPa -0.1 MPa For positive pressure 0 to 500 kPa 0 500 kPa -50 kPa Range Rated pressure range C D F For low differential pressure 0 to 2 kPa 0 2 kPa -0.2 kPa -32No.PS-OMG0002-G Dimensions Body dimensions Mounting using mounting option
capacity [cm3] 8 25 45 Bowl material Polycarbonate Bowl guard Standard (Polycarbonate) 5 m 80 100 180 230 200 310 370 Water drop removal type (-S) 40 m 100 130 210 340 230 390 500 80 m Recommended flow rate Note 5) [L/min (ANR)] 5 m 100 140 190 250 210 350 440 Large flow type (-T) 40 m 120 180 230 380 250 480 660 80 m Weight [kg] 0.08 0.18 0.36 Note 1) The size of solid particles collectable
Normal output Reversed output P_1 = A (A B)/4 n_1 = B + (A B)/4 A = Maximum pressure H_1 = (A B)/2 H_1 = (A B)/2 B = Minimum pressure In the OUT2 setting, the above P_1, n_1 and H_1 will be P_2, n_2 and H_2 respectively.
If using other screws, switch may be damaged. 12-13-16 17 Solid State Switch Direct Mounting Style D-Y59 /D-Y69 /D-Y7P(V) A B A B For details about certified products conforming to international standards, visit us at www.smcworld.com.
If using other screws, switch may be damaged. 12-13-16 17 Solid State Switch Direct Mounting Style D-Y59 /D-Y69 /D-Y7P(V) A B A B For details about certified products conforming to international standards, visit us at www.smcworld.com.
fluid power -General rules relating to systems IEC 60204-1: Safety of machinery -Electrical equipment of machines (Part 1: General requirements) ISO 10218-1992: Manipulating industrial robots-Safety JIS B 8370: JIS B 8361: JIS B 9960-1: -1) JIS B 8433-1993: *2) 1. 2. 3. 1. 2. 3. 4. 3 A / 1 1.5 *3) *3)1 1 () 4 IP8000ExdBT5 1. 1 IP8000 IP8100 420mADC()*1 23515(420mADC) 0.140.7MPa
P-1 = A (A B) / 4 H-1 = (A B) / 2 A = Maximum pressure value B = Minimum pressure value For low differential pressure For low pressure For compound pressure PSE533 PSE543 PSE563 For positive pressure For vacuum Pressure range C Display calibration function This function eliminates slight differences in the output values and allows uniformity in the numbers displayed.