The 24 VDC supply to the BK RLS (lock release) is only required for the adjustment and the recovery in the emergency. 19 - 5.4 Stop circuits The controller can provide a controlled stopwhen the +24 VDC is removed from the EMG pin.
Prepare the switch (power supply voltage: 24 VDC, contact capacity: 35 mA or more, minimum load current: 5mA) and suitable connector cable. HRS Series 3.3 Installation 3-21 DOC1001322 Chapter 3 Transport and Setting Up 2. Wire the contact input / output signal connector as follows and connect it to this product.
Prepare the switch (power supply voltage: 24 VDC, contact capacity: 35 mA or more, minimum load current: 5mA) and suitable connector cable. HRL Series 3.3 Installation 3-21 HRX-OM-W060 Chapter 3 Transport and Setting Up 2. Wire the contact input / output signal connector as follows and connect it to this product.
Prepare the switch (power supply voltage: 24 VDC, contact capacity: 35 mA or more, minimum load current: 5mA) and suitable connector cable. HRL Series 3.3 Installation 3-21 HRX-OM-Y098 Chapter 3 Transport and Setting Up 2. Wire the contact input / output signal connector as follows and connect it to this product.
Prepare the switch (power supply voltage: 24 VDC, contact capacity: 35 mA or more, minimum load current: 5mA) and suitable connector cable. 3.3 Installation HRL Series 3-22 HRX-OM-X037 Chapter 3 Transport and Setting Up 2. Wire the contact input / output signal connector as follows and connect it to this product.
Table 1 Model Solenoid Valve (CV) Speed Controller Tubing AS1-M5 Note) Make sure to use speed controller CRB2BW40 0.1 to 0.2 4 / 2.5 In meter-out control. 5 4. Installation 4-1Air Supply Caution Filter and regulate air supplied to Rotary Actuator by using SMC Air Filter and Regulator (Series AR). Do not apply lubricant since this is non-lube type.
Solid sphere Position of rotational axis: Through the center of diameter r 2 2 r I = m5 29 - Kinetic energy Table 10 shows the allowable kinetic energy of the rotary table. Here, the angular speed can be found from the formula below.
Connect so that polarity is matched to the connectors (+), (-) and A, B and COM indicators, In the case of voltage specifications other than 12 or 24 VDC, take care to avoid mistaking polarity, as there is no diode to prevent reverse current. In the event that lead wires are connected in advance, they will be as shown below.
(Effective energizing time is over 40ms at 24 VDC.) Refer to the electrical power waveform as shown below.
Solid sphere Position of rotational axis: Through the center of diameter 2 2 r I = m5 27 - Kinetic energy Table (9) shows the allowable kinetic energy of the rotary actuator. The end angular speed is obtained by: Table 9.
based on SMC test conditions) is 10 million cycles or more.Orifice diameter of LVM11: 1.5mm, Orifice diameter of LVM10: 1.4mm , Available with power-saving circuit , 2 port N.C. or N.O. types; 3 port Universal type , Diaphragm choice of EPDM, FKM or Kalrez , Wetted part material: PEEK or PFA (body/plate), CHEMICAL VALVE, 2-P0RT, VALVE, LVM CHEMICAL VALVE, 2 PORT, AA, LVM BODY PORT, M5
D I N 'E Terminal 'T Conduit Temlnal 'H 24' Lead hing 01 %'(AXSrd.) t M5 NOM 10-32 ilanual Overrida _Recessed, Nonlocking (Std.)
Minimum unit setting Applicable fluid Power supply voltage Current consumption Switch output 0.0 to 101.0 kPa 10.0 to 105.0 kPa 500 kPa 0.1 kPa Air, Non-corrosive gas, Non-flammable gas ZSE30A-01-N-ML (NPN open collector 1 output) ZSE30A-01-P-ML (PNP open collector 1 output) ZSE30A-01-A-ML (NPN open collector 2 outputs) ZSE30A-01-B-ML (PNP open collector 2 outputs) IRV10 IRV20 12 to 24 VDC
Actuation: 1 (Normally Closed), Coil Specification: 0.35W, Voltage: 5 (24 VDC), Electrical Entry: L (L Plug Connector, w/Lead Wire 300 mm), Light/Surge Voltage Suppressor: Z (w/ Light/Surge Voltage Suppressor, DC, AC Specifications, Manual Override: Non-locking Push Type, Port Size: M5 (w/Sub-plate)
Actuation: 1 (Normally Closed), Coil Specification: 0.35W, Voltage: 5 (24 VDC), Electrical Entry: M (M Plug Connector w/Lead Wire 300 mm), Light/Surge Voltage Suppressor: Z (w/ Light/Surge Voltage Suppressor, DC, AC Specifications, Manual Override: Non-locking Push Type, Port Size: M5 (w/Sub-plate)
Actuation: 1 (Normally Closed), Coil Specification: 0.35W, Voltage: 5 (24 VDC), Electrical Entry: LO (L Plug Connector w/o Connector), Light/Surge Voltage Suppressor: w/o Light/Surge Voltage Suppressor, DC, AC Specifications), Manual Override: Non-locking Push Type, Port Size: M5 (w/Sub-plate)
Actuation: 2 (Normally Open), Coil Specification: 0.35W, Voltage: 5 (24 VDC), Electrical Entry: LO (L Plug Connector w/o Connector), Light/Surge Voltage Suppressor: w/o Light/Surge Voltage Suppressor, DC, AC Specifications), Manual Override: Non-locking Push Type, Port Size: M5 (w/Sub-plate)
Actuation: 2 (Normally Open), Voltage: 6 (12 VDC), Electrical Entry: L (L Plug Connector, w/Lead Wire 300 mm), Light/Surge Voltage Suppressor: U (w/ Light/Surge Voltage Suppressor, DC), Manual Override: Non-locking Push Type, Port Size: M5 (w/Sub-plate)