SMC Corporation of America
Elite Part Number Search
Search Results "ZSE20-P-P-C6H-L"

OK OK NG OK OK 17 4-2 W (N) WeN) () V m/s) () Va (m/s) L (m) M (Nm) E (J) g (m/s) (9.8m/ ) (N) W1 (Nm) V=1.4Va MFL F (V=0.) 1 L <> W1.VaW10 M2F2L2 F2 M= WeL =5VaWL 3 2 L W2 M3F3L3 F3 an= F Fmax 3 L F W4 Fmax : () W Ek= W V 2g (V=0.

L k Imaginary stroke L' = (Stroke) + k + L k: Distance between the center and end of the plate 6 (Example) q When using CXSJM6-10 and L = 15 mm: Imaginary stroke L' = 10 + 2.75 + 15 = 27.75 Therefore, the graph used for your model selection should be the one for CXSJM6-30 6 ). 2.75 mm 10 4 mm 15 5 mm 20 6 mm 25 w When using CXSJL25-50 and L = 10 mm: Imaginary stroke L' = 50 + 6 + 15 = 71

Temperature specifications Symbol Nil M9N (L) M9P (L) M9B (L) A90 (L) A93 (L) M9// Symbol Nil H0 Temperature range 5 to 60C 5 to 150C Without auto switch (without built-in magnet) Remarks Auto switch D-M9N (L) D-M9P (L) D-M9B (L) D-A90 (L) D-A93 (L) Solid state switch 6. No. of auto switches/Detecting position Quantity Without auto switch 2 pcs. 1 pc. 1 pc.

control Port 1 0: L+ ON, 1: L+ OFF 1 L+ control Port 2 0: L+ ON, 1: L+ OFF 5 2 L+ control Port 3 0: L+ ON, 1: L+ OFF 3 L+ control Port 4 0: L+ ON, 1: L+ OFF 4..7 Reserved 0 -105No.EX-OMX1011 Configuration format (EX600-LAB1 / EX600-LBB1) Byte 6 to 45 EX600-LAB1 / EX600-LBB1 (46 byte) Byte Bit Parameter Setting value PortConfig Port 1 0: Deactivated 1: IOL_Manual 2: IOL_Autostart 3:

Components listed as polysulfone are made of Amoco UDEL P-1700 Polysulfone #937 (black).

Port size L M (F) (E) (B) J K (C) Port size: Size 14 A ( 52) (20) Silencer (Option) Pilot port 1/8, 1/4 (Rc, NPT, G) H Exhaust port 3/8 2 x P Port size (F) L M (G) (E) (B) J K 20 (C) Dimension in ( ) shows the dimension after tightening.

The clip is commonly used to secure the manifold block and fittings. q 1) Vacuum release application Use 3 (R) port for vacuum pressure and 1 (P) port for vacuum release pressure. The pressure differential between 3 (R) and 1 (P) is the maximum operating pressure differential for each type.

B: Locking style (Slotted) : Non-locking push style (Flush) VP 4 1 (P) 3 (R) VQ VQZ Body style 2 Body ported Electrical entry VZ G: Grommet (DC Specification) L: L plug connecor with lead wire M: M plug connecor with lead wire MO: M plug terminal without connector LO: L plug terminal without connector VS Function Symbol Specification DC AC (1.0W) (3) Standard (1) High pressure (Metal seal

Flat bracket Dimensions L-bracket Description Part no.

Note) $1, %4 will not be required for the one without rear plate. 9-4-6 7 Fine Lock Cylinder with Guide Series MLGC Dimensions Basic style: With rear plate MLGCB--R4-F through Counterbore G Back side 4-H 2-O through Rear plate P Head side cylinder port BP Unlocking port Unlocked when pressurized CL CL1 P Rod side cylinder port MLGC W U A' CNG MNB Courtesy of Steven Engineering, Inc.-230

Stroke adjustment unit mounting diagram Stroke adjustment unit Stroke Adjustment Unit Symbol Right side stroke adjustment unit Intermediate fixing spacer Example of L6L7 attachment Left side Right side L: With low load shock absorber + Adjustment bolt L unit Short spacer L unit Long spacer Without unit With short spacer With long spacer SL L L6L L7L SL6 LL6 L6 L7L6 SL7 LL7 L6L7 L7 Without

Note) $1, %4 will not be required for the one without rear plate. 9-4-6 7 Fine Lock Cylinder with Guide Series MLGC Dimensions Basic style: With rear plate MLGCB--R4-F through Counterbore G Back side 4-H 2-O through Rear plate P Head side cylinder port BP Unlocking port Unlocked when pressurized CL CL1 P Rod side cylinder port MLGC W U A' CNG MNB BP Lock port for pressure lock (Plug with

SP ZCUK Max.660 L/min (ANR) 5,40,80 m AMJ Large flow capacity Nominal filtration rating AFJ AFJ AMV Large flow type (P=4 kPa) Elements can be reused by washing them. For 40 m and 80 m ZH -X185 Related Products Water drops can be removed. Water drop removal ratio: 80%. At recommended flow rate (representative values).

The voltage (across P-N or P+-N-) of the main circuit converter is displayed. 0 to 900 V -79- 6. CC-Link setting CC-Link function of the driver. Wiring and PLC setting must to satisfy the specifications.

M~-ill w". w r: L-+. !ill! L 3() same side I HI 49 65.5 55 5 SeIIh, Itrokt end within ::/-1.5mm or less ollhe above specIfied positioning order to mulmlzt the high magnetic fielll reslstabilhy. L, ' N X NZ NX NZ L, P i A A 0ND. o oNDI1'o A, U, NX bJ AppI bore size A ., E, 11 MM 'R, U. -. . No. CQ2 Single Rod Clevis (mm) C02 Double Rod Clevis (mm) ;1 AppI bon ...

[mg/L] 70 or less 200 or less Calcium hardness [mg/L] 50 or less 150 or less Ion silica [mg/L] 30 or less 50 or less Iron [mg/L] 0.3 or less 1.0 or less Copper [mg/L] 0.1 or less 0.3 or less Sulfide ion [mg/L] Not detected Not detected Referential Ammonium ion [mg/L] 0.1 or less 1.0 or less item Residual chlorine [mg/L] 0.3 or less 0.3 or less Separation carbonic acid [mg/L] 4.0 or less

.: XT13-406-X200) Note) Applicable to special manifold, too. 644 Valve for Water and Chemical Base Fluids (2/3 Port Air Operated Valve) VCC Series VCC Series I N D E X P.646 How to Order P.648 Specifications/Weight P.650 Dimensions Single valve unit P.651 Manifold P.652 SUS316L Stainless steel fittings P.654 Special Tools VNA VNB Disassembly/Assembly/ Maintenance Procedure P.656 SGC