t Exhaust flow path OUT SUP y Inner valve Signal pressure enters the input chamber q and diaphragm A w and exerts a downward force on diaphragm B e.

B 0.2 A 0.2 Bore size [mm] A [mm] B [mm] Hexagon socket head cap screw 12 (10 x 2) 52 11 M3 x 0.5 16 (12 x 2) 57 11 M4 x 0.7 20 (16 x 2) 75 14 M4 x 0.7 25 (20 x 2) 84 17 M5 x 0.8 32 (25 x 2) 98 21 M6 x 1.0 40 (32 x 2) 107 27 M8 x 1.25 50 (40 x 2) 135 37 M8 x 1.25 63 (45 x 2) 146 40 M10 x 1.5 80 (56 x 2) 184 50 M12 x 1.75 100 (71 x 2) 219 62 M14 x 2 7.

Dimensions AS420 AS500 AS600 67.5 74 90 1/4, 3/8, 1/2 3/4 1 38 42 55 122 115 158 112 105 148 50 50 62 L1 L2 L4 Min.

106 2 2.3 3.2 6 7 10 8 8 10 10 12 15 40 50 55 66 80 88 84 100 110 28 34 50 5 5 9 26 32 37 37 37 37 108 155 221 13 16 19 20 22 25 1/4, 3/8 3/8, 1/2 1/2, 3/4 1in = 25.4mm 5

A IDFC60-23-TIDFC70-23-T IDFC80-23-TIDFC90-23-T M3.5 8.5mm M4.0 9.5mm [3.2.5 ] IDFC60/70/80/90 Series 11-3 IDX-OM-W095 T 11.5 IDFC60/70-23-T A B AC 230V50Hz CM OLR FM MC MC2 PRS ILS THR C01 C11 TB CN TDR GFCI EDV PE BK WH IDFC80/90-20-T GR SY A B AC 230V50Hz BU BR YE OR G/Y / IDFC60/70/80/90 Series 11-4 IDX-OM-W095 V 12 V V 12.1 0 () 12.2 ( 10m) (12mm)

25 4 x M8 x 1.25 Effective thread depth 12 NA CC0.1 ZZ + Stroke S + Stroke W K 25 2 TF TN Nil P (Piping port) R Model L K I D B CC ZZ X W S NA Q V 300.007 0.037 100 12-REA50 M8 x 1.25 32 58 55 180 G1/4 86 52.4 25 110 27.5 176 60 60 Rc1/4 NPT1/4 320.007 0.043 12-REA63 M10 x 1.5 38 65.4 72 26 122 69 34.5 188 70 70 192 Rc1/4 NPT1/4 G1/4 862 A Specific Product Precautions Be sure to read this

ZFA200 ZFA100 Nil T Rc B NPTF F G ZFA200 How to Order Manifold (2 to 10 stations) Symbol Indicate both the symbols for air suction filter and bracket part no.

Ammonia water (28%) 18 Alkalis Resistivity value (Mcm) 16 Formaldehyde (35%) Aldehyde Formaldehyde (35%) Methyl alcohol, butyl alcohol, ethyl alcohol, propyl alcohol Alcohol 14 Dioxane Ethyl ether Ether 12 Ethyl ether Hexane Benzene, toluene, hexane, xylene Benzene Hydrocarbon 10 Can be used depending on temperature conditions (please consult with SMC). 8 0 0 5 10 15 20 25 30 35 40 45 50 55

137 92 80 70 M5 x 0.8 x 8 M6 x 1.0 x8 M6 x 1.0 x10 12REA 50/63 0 -0.2 L NA 33 2-Rc, NPT, G 1/4 14 14 E(h8) E(h8) X D I 4-TC 14 14 Effective thread depth R 23 22 K W 23 25 2 4-M8 x 1.25 25 8-Q 14.5 C 0.1 + Effective thread depth 12 Effective thread depth R B S + Stroke 2 ZZ + Stroke Q x R S TC x R Model L 122 110 K 38 32 C 70 60 X ZZ NA E D B 72.2 58.2 I 70 60 W 12-REA63 12-REA50 100 86 66

Assy 3-4 3-5/ -1- 1) 2) (ISO/IEC) (JIS) *1) ISO 4414: Pneumatic fluid power -General rules relating to systems ISO 4413: Hydraulic fluid power -General rules relating to systems IEC 60204-1: Safety of machinery -Electrical equipment of machines (Part 1: General requirements) ISO 10218-1992: Manipulating industrial robots -Safety JIS B 8370: JIS B 8361: JIS B 9960-1: 1 ) JIS B 8433-1993

Note 1) ISO 4414: Pneumatic fluid power -Recommendations for the application of equipment to transmission and control systems Note 2) JIS B 8370: General Rules for Pneumatic Equipment Warning 1. The compatibility of pneumatic equipment is the responsibility of the person who designs the pneumatic system or decides its specifications.

+ Stroke A + Stroke FA FB S HR E b a With front lock XAH7 c d e MO XB T-slot dimensions (mm) DM HN XAH7 XC XL Bore size (m) a b c d e End lock mechanism (locking type manual release ) 6.5 10.5 5.5 3.5 9.5 32 Section XX detailed diagram 6.5 10.5 5.5 4 11 40 8.5 13.5 7.5 4.5 13.5 50 11 17.8 10 7 18.5 63 LL With rear lock (mm) Standard strokes (mm) Bore size (mm) ML NN OA B C DA FA FB G GA GB

D-P74 auto switch is Dolarized when DC24V is used: white lead wire is positive and black lead wire is negative. lf connected in reverse the LED will not light 14 7a9{C Conversion Chart English to Metric (lvlultiply _ by _ To Obtain ) Metric to English (l\ilultiply _ by To Obtain ) Torque m m f t . l b m m f t . l b cm m Pressure in(H2O) 2.5357 x 1o-3kdcm2 in(Hg) 0.03518 kglcm2 mm2 psi 6.897

Note 2) JIS B 8370: General Rules for Pneumatic Equipment Warning 1. The compatibility of pneumatic equipment is the responsibility of the person who designs the pneumatic system or decides its specifications.

108 170 260 410 Nil A B * Air purication rating: JIS B 8392-1 (ISO8573-1) Quality Degree 4, 4, 2 or more Guide assembly Adjustment bolt assembly None 736

ZF ZFA100 Port size Symbol Model A B 18 20 28 ZFA200 1 8 1 4 ZP Manifold ZCU AMJ Misc.

D-P74 auto switch is Dolarized when DC24V is used: white lead wire is positive and black lead wire is negative. lf connected in reverse the LED will not light 14 7a9{C Conversion Chart English to Metric (lvlultiply _ by _ To Obtain ) Metric to English (l\ilultiply _ by To Obtain ) Torque m m f t . l b m m f t . l b cm m Pressure in(H2O) 2.5357 x 1o-3kdcm2 in(Hg) 0.03518 kglcm2 mm2 psi 6.897

VPA3 2 x Mounting hole Port size Rc (EXH port) Port size 2 x Rc (IN, OUT port) Port size Rc Model Mounting hole IN, OUT EXH A B C D E F G H J K L 3 8 1 2 3 4 VPA3145 71 3 4 8.5 85 14 52 55 93 32 87.4 36 71 80 3 4 VPA3165 82.6 1 4 8.5 1 110 17 68 75 118 45 113 36 71 95 1 1 4 1 1 1 1 4 1 2 VPA3185 118 13 2 132 14 80 95 140 52 140 41 81 105 2 1575

Specifications B B C C C Standard pressure dewpoint -40F Optional pressure dewpoint -100F Minimum working pressure 58 psig Maximum working pressure 232 psig A A Power supply 12VDC to 24VDC or 100VAC to 240VAC Minimum inlet temperature 35F Maximum inlet temperature 122F Minimum ambient temperature 41F IDW4N-IDW35N IDW45N-IDW365N Purge rate 20% IDW04N-IDW175N IDW215N-IDW365N Dryer correction

IZH IZH BEST DETECTING POSITION 50mm Sensor part 2 x 3.4 600 16.6 SMC 9 4.8 87.5 BEST DETECTING POSITION 50mm 13 8.8 0.5 6.5 7 (7.5) (175) 60 (12.3) BEST DETECTING POSITION 50mm 86 (55) (9.3) 21 519 IZH10 Series Names and Functions of Individual Parts LCD display Display of charged electricity Display of peak/bottom value Peak display P Bottom display b Measured Potential 20.0kV AUTO POWER-OFF