SMC Corporation of America
Elite Part Number Search
Search Results "ISE20B-X-P-01-WA2"

1 Quick Exhaust Valve Series AQ Model Excellent exhaust characteristics Large flow capacity Compact and lightweight A wide selection of models Port size Effective area (mm2) Weight (g) Model IN OUT OUT EXH M5 x 0.8 AQ1500-M5 AQ1510-01 AQ2000-01 AQ2000-02 AQ3000-02 AQ3000-03 AQ5000-04 AQ5000-06 2 4 25 35 40 60 105 135 2.8 5.8 25 40 42 70 115 180 25 45 110 105 215 205 690 650 1 8 1 8 1 4

With One-touch fitting Port size M3 M3 x 0.5 M5 x 0.8 10-32 UNF 1/8 1/4 3/8 1/2 Thread type M5 Metric thread (M3, M5) Unified thread (10-32 UNF) R NPT AS U10/32 01 02 03 04 Nil ASP N ASN Needle Valve/Flow Characteristics AQ AS1201F-M3, AS1211F-M3 AS1301F-M3, AS1311F-M3 AS1201F-M5-02, AS1211F-M5-02 AS1201F-M5, AS1211F-M5 AS1301F-M5, AS1311F-M5 AS2201F-01, AS2211F-01 AS2301F-01, AS2311F-01

Metric thread (M3, M5) Unified thread (10-32 UNF) R NPT M3 x 0.5 M5 x 0.8 10-32 UNF 1/8 1/4 3/8 1/2 ASN M5 Nil U10/32 01 02 03 04 AQ N ASV AK Needle Valve/Flow Characteristics Note) The flow characteristics are representative values.

/See 2.1 Specifications on p.9 /See 3.1 Specifications on p.12 Use within specification range. 3) Load/resistance more than /See 2.1 Specifications on p.9 specified range is being applied /See 3.1 Specifications on p.12 to the actuator.

Refer to p.0-26 and 0-27 for Safety Instructions and common precautions on the products mentioned in this catalog, and refer to p.1.0-1 and 1.0-2 for precautions on every series. Selection Warning qThe residual secondary pressure cannot be released by releasing the supply pressure. To release the residual pressure, contact SMC.

For vacuum/ compound pressure ISA2 ZSE30A 01 N M Option 3 Note) Calibration certificate Nil Y K T Note) Operation manual ISE35 Symbol Rated pressure range ZSE30A ZSE30AF 0 to 101 kPa 100 to 100 kPa PSE Piping specifications IS 01 Note) All texts in both English and Japanese.

Rated Vacuum Range: -101 to 0 kPa, Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: Unit Selection Function, Piping Specification: 01 (R1/8), Lead Wire: W (Lead Wire w/Connector, 5-core, 2m Lead Wire w/Waterproof Cover), Bracket: A2 [Bracket B (ZS-46-A2)]

Rated Vacuum Range: F (-100 to 100 kPa), Output Specification: T (PNP Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: 01 (R 1/8), Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof), Bracket: A2 (Bracket B, Horizontal Mounting)

Rated Vacuum Range: -101 to 0 kPa, Output Specification: Y (PNP Open Collector 2 Outputs + Copy Function), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: 01 (R 1/8), Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof), Bracket: A2 (Bracket B, Horizontal Mounting)

Rated Vacuum Range: -101 to 0 kPa, Output Specification: T (PNP Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: 01 (R 1/8), Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof), Bracket: A2 (Bracket B, Horizontal Mounting)

Rated Vacuum Range: -100 to 100 kPa, Output Specification: PNP Open Collector 2 Outputs + Analog Voltage Output, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: R 1/8, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof, Bracket: Bracket B, Horizontal Mounting, Operation Manual: -

Rated Vacuum Range: -101 to 0 kPa, Output Specification: PNP Open Collector 2 Outputs + Copy Function, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: R 1/8, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof, Bracket: Bracket B, Horizontal Mounting, Operation Manual: -

Rated Vacuum Range: -101 to 0 kPa, Output Specification: PNP Open Collector 2 Outputs + Analog Voltage Output, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: R 1/8, Lead Wire: Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof, Bracket: Bracket B, Horizontal Mounting, Operation Manual: -

Rated Vacuum Range: -101 to 0 kPa, Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: Unit Selection Function, Piping Specification: R1/8, Lead Wire: Lead Wire w/Connector, 5-core, 2m Lead Wire w/Waterproof Cover, Bracket: A2 [Bracket B (ZS-46-A2)], Operation Manual: -

Left IN1(P) Piping VHS500-06 VHS501-06 VHS400-04 VHS401-04 VHS400-03 VHS401-03 VHS400-02 VHS401-02 Right IN1(P) 3 4 1 2 3 8 1 4 Port size Effective area (mm2)(CV) Weight (kg) 93(5.22) 57(3.20) 35(1.97) 21(1.18) 105(5.90) 76(4.27) 54(3.03) 35(1.97) 0.29 1(P)2(A) 2(A)3(R) 0.34 0.25 0.27 Left or right to the front face of the handle.

Description Cover Case Gasket/Seal Element Material Zinc die-casted Aluminum die-casted NBR Polyester, ABS AMJ Element size (mm) 43 x 42 x 12 43 x 40 x 22 Applicable filter model Part no. EJ001H-030N EJ101H-030N ZFA100 ZFA200 Misc.

ZSE2-01-15CN1 pc. 3 m 30 ZS-10-5 A-501 pc. 5 m 50 780

Applicable filter model Element Size Set description EJ001H-030N ZFA100 43 x 42 x 12 Element EJ101H-030N ZFA200 43 x 40 x 22 Element < Replacement Gasket Part No. > Part No. Applicable filter model AL-204H ZFA100 AL-205H ZFA200 -10- 1. Stop operation and reduce the filter's internal pressure to atmosphere. 2. Loosen the stop pin and open the cover. 3.

Class Instance Attribute Description Value 01h (01) 01h (01) MAC ID (Node address) 0 to 63 03h 0: 125 kbps 1: 250 kbps 2: 500 kbps (DeviceNetTM) 01h (01) 02h (02) Baud_rate (Communication speed) : The address and communication speed set in SW mode will be kept even after the DeviceNetTM communication power supply to the SI unit is turned off.