, Operating Pressure Range(MPa): 0.2~1, Format: Shock absorber for high energies, Connection port location: Symmetrical type, Switch: A93, Lead wire(m): 0.5, Number Of Switches: 2 pcs., Port types: Rc 1/8, Connector Type: a: None, Specification: Standard type
Operating Pressure Range(MPa): 0.2~1, Format: Shock absorber for high energies, Connection port location: Symmetrical type, Switch: A93, Lead wire(m): 0.5, Number Of Switches: 2 pcs., Port types: Rc 1/8, Connector Type: a: None, Specification: Standard type
, Operating Pressure Range(MPa): 0.2~1, Format: Shock absorber for low energies, Connection port location: Standard type, Switch: A93, Lead wire(m): 0.5, Number Of Switches: 2 pcs., Port types: Rc 1/8, Connector Type: a: None, Specification: Standard type
, Operating Pressure Range(MPa): 0.2~1, Format: Shock absorber for low energies, Connection port location: Standard type, Switch: A93, Lead wire(m): 3, Number Of Switches: 2 pcs., Port types: Rc 1/8, Connector Type: a: None, Specification: Standard type
Operating Pressure Range(MPa): 0.2~1, Format: Shock absorber for low energies, Connection port location: Standard type, Switch: A93, Lead wire(m): 3, Number Of Switches: 2 pcs., Port types: Rc 1/8, Connector Type: a: None, Specification: Standard type
Operating Pressure Range(MPa): 0.2~1, Format: Shock absorber for low energies, Connection port location: Symmetrical type, Switch: A93, Lead wire(m): 3, Number Of Switches: 2 pcs., Port types: Rc 1/8, Connector Type: a: None, Specification: Standard type
: A93, Lead wire(m): 3, Number Of Switches: 2, Port types: Rc 1/8
, Switch: A93, Lead wire(m): 0.5, Number Of Switches: 2, Port types: Rc 1/8
Oscillation Angle A: [Arbitrary Setting Type] Free setting type, Type: Rotary Table 2-Point Stop, Main Body Shape: Block Shape, Operation Method: Double Rack, Rigidity Accuracy: Standard, Environment, Applications: Standard, Allowable Kinetic Energy (Range)(J): -, Valves: Not Provided, Allowable Kinetic Energy(J): 0.048, Format: Includes adjusting bolt, Size: 30, Switch: A93, Lead wire(m)
Oscillation Angle A: [Arbitrary Setting Type] Free setting type, Type: Rotary Table 2-Point Stop, Main Body Shape: Block Shape, Operation Method: Double Rack, Rigidity Accuracy: Standard, Environment, Applications: Standard, Allowable Kinetic Energy (Range)(J): -, Valves: Not Provided, Allowable Kinetic Energy(J): 0.048, Format: Includes adjusting bolt, Size: 30, Switch: A93, Lead wire(m)
: A93, Lead wire(m): 0.5, Number Of Switches: 2, Port types: Rc 1/8
: A93, Lead wire(m): 3, Number Of Switches: 2, Port types: Rc 1/8
: A93, Lead wire(m): 3, Number Of Switches: 2, Port types: NPT 1/8
Oscillation Angle A: [90°] 90°, Torque (Range)(N⋅m): Less than 1 / 1 to Less than 3 / 3 to Less than 6, Type: Rotary Actuator One Side Shaft Output, Main Body Shape: Block Shape, Operation Method: Single Rack, Rigidity Accuracy: Standard, Environment, Applications: Standard, Allowable Kinetic Energy (Range)(J): 0.1 to Less than 1, Tube Nominal Diameter: 30, Valves: Provided, Allowable Kinetic
Oscillation Angle A: [90°] 90°, Torque (Range)(N⋅m): Less than 1 / 1 to Less than 3 / 3 to Less than 6, Type: Rotary Actuator Both Sides Shaft Outputs, Main Body Shape: Block Shape, Operation Method: Single Rack, Rigidity Accuracy: Standard, Environment, Applications: Standard, Allowable Kinetic Energy (Range)(J): 0.01 to Less than 0.1, Tube Nominal Diameter: 30, Valves: Provided, Allowable
Oscillation Angle A: [180°] 180°, Torque (Range)(N⋅m): Less than 1 / 1 to Less than 3 / 3 to Less than 6, Type: Rotary Actuator Both Sides Shaft Outputs, Main Body Shape: Block Shape, Operation Method: Single Rack, Rigidity Accuracy: Standard, Environment, Applications: Standard, Allowable Kinetic Energy (Range)(J): 0.01 to Less than 0.1, Tube Nominal Diameter: 30, Valves: Provided, Allowable
Cylinder (Tube) Inner Diameter(φ): 16, Stroke(mm): 30, Cylinder Operation Method: [Double Acting] Double Acting, Rod Operation Method: Single Rods, Main Body Shape: Standard, Additional Function: Standard, Environment, Applications: Standard, Operating Temperature(°C): -, End Locking: No, Valves: No, Operating Pressure(MPa): 0.06~0.7, Cushion: Rubber cushion, Auto Switches: A93, Lead Wire
Operation Method: Move Turning, Cylinder Diameter(Ø): 12, Stroke S(mm): 30, Support Type: [Through Hole, Both Ends Tapped(Common)] Through Hole/Both Ends Tapped Commonly (Standard), Rod Tip Shape: [Others] Other, Rotation Angle θ: [90°] 90°±10°, Clamping Force(kN): 0.04, Max.
Operation Method: Move Turning, Cylinder Diameter(Ø): 16, Stroke S(mm): 30, Support Type: [Through Hole, Both Ends Tapped(Common)] Through Hole/Both Ends Tapped Commonly (Standard), Rod Tip Shape: Female Thread, Rotation Angle θ: [90°] 90°±10°, Clamping Force(kN): 0.075, Max.
Operation Method: Move Turning, Cylinder Diameter(Ø): 20, Stroke S(mm): 30, Support Type: [Through Hole, Both Ends Tapped(Common)] Through Hole/Both Ends Tapped Commonly (Standard), Rod Tip Shape: Female Thread, Rotation Angle θ: [90°] 90°±10°, Clamping Force(kN): 0.1, Max.