This item is applicable U n i t N u m b e r M O D E < 0 only when multiple units are used. 2. Baud Rate B a u d R a t e M O D E < 1 2 0 0 b / s Setting range : 600, 1200, 2400, 4800, 9600, 19200b/s Indicated content : Baud rate (Ex. : 1200b/s) Function : Sets baud rate for communication. 3.
(305) 60 77 96 113 46 60 76 85 34 40 50 60 24 36 41 50 135 164.5 200 219 50 60 79 90 77 95.5 111 119 1 8 VNC 1 4 1 4 VNH Note) ( ): CE compliant product (-Q) VND Model J K L M N O P Q R S T U V VNH1 -10A A B VNH2 -15A A B VNH3 -20A A B VNH4 -25A A B M5 x 0.8 depth 5.5 M6 x 1 depth 6 M8 x 1.25 depth 6 M8 x 1.25 depth 6 202.5 232 267 286.5 29 36 48 51 25 30 35 38 30 40 50 56 37 43 50.5 58.5
B IN OUT 8-18 L E H A DIN terminal: D Conduit: C Approx. 280 N (N) J J (44) G 1/2 M M G 1/2 Cable 6 to 12 (Q) Conduit terminal: T J (N) 32 25 G 1/2 M (mm) Grommet Conduit DIN terminal Conduit terminal Electrical entry (AC/Class B coil) Model M 93 N 33 36 36 M 88 N 51.5 54 54 M 89 N 68.5 71 71 Q 56.5 59 59 M 88 N 103.5 Q 72.5 75 75 Normally closed VXD2272 VXD2382 VXD2392 Normally open VXD2270
-B 25 No.VQC1000V-OMM0001-B 26 No.VQC1000V-OMM0001-B 27 No.VQC1000V-OMM0001-B 28 No.VQC1000V-OMM0001-B 29 No.VQC1000V-OMM0001-B 30 No.VQC1000V-OMM0001-B When the valve is failing, use this flow chart to clarify the cause of the failure and take countermeasures appropriate for the cause.
K With air supply valve, Vacuum release valve Thread type Nil Rc T F NPTF G Table (1) Combination of Nozzle Diameter and Standard Supply Pressure Standard supply pressure (MPa) Nozzle diameter M (0.35) S (0.45) H (0.5) 0.5 0.7 1.0 1.3 1.5 Table (2) Lead wire with 4-wire connector P5022-6-1 (0.6 m) P5022-6-2 (3 m) 13-4-23 4 Series ZMA Model H M Standard supply pressure Nozzle diameter (mm)
Hs Ht A B Hs A B Hs A B Hs Ht B D-P4DW D-M9 D-M9W D-M9A 12 D-A9 Hs D-B54 Note) The above drawing is the switch band mounting example for the D-P4DWS.
Note) Component parts Aoolicable manifold base MBF261--3;-18 M a n i i o l d b l o c k O , C l a m p O ' O o r i n g O ' O ' O ' O Adapter O , Pin housing. Guide. Insertllug lead wire Plug-in type Connector lead wires o Manilold block assy ' :o-side ports A, B l-1l8 P A, B bottom 2-1l8 P, A, B bottom w/ (114 A, B side) MBF261.-3r-1A M a n i f o l d b l o c k O , C l a m p O , @ .
Note) Component parts Aoolicable manifold base MBF261--3;-18 M a n i i o l d b l o c k O , C l a m p O ' O o r i n g O ' O ' O ' O Adapter O , Pin housing. Guide. Insertllug lead wire Plug-in type Connector lead wires o Manilold block assy ' :o-side ports A, B l-1l8 P A, B bottom 2-1l8 P, A, B bottom w/ (114 A, B side) MBF261.-3r-1A M a n i f o l d b l o c k O , C l a m p O , @ .
B A B B 45 45 2 x 10-32 UNF depth 0.25 (6.3) (Mounting hole) 2 x 10-32 UNF depth 0.25 (6.3) (Mounting hole) 1.0 (25.4) 1.0 (25.4) AP3650 AP3657 1.88 (47.8) 0.44 (11.2) 3.02 (76.7) 0.13 (3.3) 0.4 (10.2) 1.87 (47.5) A B B 0.44 (11.2) 3.6 (91.4) 45 1.0 (25.4) 2 x 10-32 UNF depth 0.25 (6.3) (Mounting hole) A B B Connections A B inch inch (mm) (mm) FV4 MV4 TW4 FV6 MV6 TW6 FV4 MV4 TW4 FV6 MV6 TW6
YP Edition B Safety Instructions Be sure to read the Handling Precautions for SMC Products (M-E03-3) and Operation Manual before use.
Altitude [m] 1. Max. ambient 2. Cooling capacity temp.
No.ZL3-OM00601-B 1.How to Order ZL3 M 06 1 K1 5 LO Z 1 E A M G 1 Without valve ZL3 M 06 1 K1 5 LO Z 1 E A M G 1 With valve Pressure switch ZL3 M 06 1 K1 5 LO Z 1 V A M W 1 with energy saving function 1) 2) 3) 4) 5) 6) 7) 8) 9) 10) 11) 12) 13) 14) 1) Max. suction flow 2) Standard supply pressure 4) Exhaust specifications 3 300L/min(ANR) M 0.35MPa Nil Exhaust through silencer H 0.50MPa
Altitude [m] q Upper limit of ambient temperature [C] w Cooling capacity coefficient Less than 1000 m 45 1.00 Less than 1500 m 42 0.85 Less than 2000 m 38 0.80 Less than 2500 m 35 0.75 Less than 3000 m 32 0.70 15. In locations where strong impacts or vibrations occur. 16.
Hs B 16 14 14 26 29 (36) D-C73C 8.5 A D-H7C 8.5 A Hs B B Hs 14 36.7 38.2 D-G5NT D-B5, B6 B A Hs Hs B A 24.5 24.5 13 33 13 33 Hs D-A3 D-G3, D-K3 B A 49 B Hs A 49 34 56 18 36 18 36 B D-A4 Hs A 34.5 56 18 36 Minimum Strokes for Auto Switch Mounting (mm) 1in = 25.4mm Minimum strokes are as follows based on the space required for mounting auto switches.
1 I/O cable length [m]*10 o Cable length [m]*6, *9 LEC Y Nil Without cable H Without cable (Connector only) 1 1.5 *9 The length of the encoder, motor and lock cables are the same. Nil Without cable 2 2 m 5 5 m A 10 m Nil: Left Motorless *10 When Without driver is selected for driver type, only Nil: Without cable can be selected. Refer to page 624 if I/O cable is required.
Please change the parameter in the initial setting. *3 The travel distance of the actuator per 1 pulse should be 10 [m/pulse]. 9 - [LECSC] LEJS40 LEJS63 LEJB40 LEJB63 Series Lead symbol H A B H A B T Lead 24 16 8 30 20 10 27 42 Parameter Para. No.
Option Symbol and Composition Fluid Name and Option Option symbol and body material Brass Stainless steel Option symbol Seal material Body material Support material (Driving parts) Standard A B G H J M (Non-leak) N P V (Non-leak) Fluid (Application) V M Silicon oil A H NBR FKM EPDM NBR FKM EPDM FKM FKM EPDM FKM Note 1) Note 1) Vacuum (up to 1.3 x 101 Pa) Fuel oil (up to 60C) Brass A H V M
B: Compliance Requirements: Caution added -Connection thread: R and NPT Changed notation of tightening method.
Mounting Front flange type Rear flange type Double clevis type B A L F G D Through hole (standard) Double end tapped Foot type Cushion/Rod end threads Bore size Action D Double acting Standard (rod end female threads) With rubber bumper Rod end male threads Nil C M Port thread type Nil TN TF 32 40 50 63 80 100 32mm 40mm 50mm 63mm 80mm 100mm Rc NPT G Combination of the above specifications