SMC Corporation of America
Elite Part Number Search
Search Results "10-SY113A-5MZ-M3"

Actuation: 2 Position Double Solenoid, Piping/EXH: Base Mount, 4 Port/Common Exhaust, Coil Specification: Standard, Voltage: 24 VDC, Electrical Entry: M Plug Connector, w/Lead Wire 300mm, Light/Surge Voltage Suppressor: w/ Light/Surge Voltage Suppressor, Manual Override: -, Port Size: -, Bracket: -

Actuation: Normally Closed, Piping: Base Mounted, Coil Specification: Standard, Voltage: 24 VDC, Electrical Entry: M Plug Connector, w/Lead Wire Length 300mm, Light/Surge Voltage Suppressor: w/Light/Surge Voltage Suppressor, Manual Override: -, Port Size: -, Thread: -, Bracket: -

Actuation: Normally Closed, Coil Specification: 0.1 W, w/Power Saving Circuit, 24, 12 VDC Only, Voltage: 24 VDC, Electrical Entry: M Plug Connector w/Lead Wire 300 mm, Light/Surge Voltage Suppressor: w/ Light/Surge Voltage Suppressor, DC, AC Specifications, Manual Override: -, Port Size: -

Actuation: Normally Closed, Coil Specification: 0.35W, Voltage: 24 VDC, Electrical Entry: M Plug Connector w/Lead Wire 300 mm, Light/Surge Voltage Suppressor: w/ Light/Surge Voltage Suppressor, DC, AC Specifications, Manual Override: -, Port Size: -

Actuation: Normally Closed, Piping: Standard, Base Mounted, Voltage: 24 VDC, Electrical Entry: M Plug Connector, w/Lead Wire Length 300 mm, Light/Surge Voltage Suppressor: w/Light/Surge Voltage Suppressor, Manual Override: -, Port: -, Bracket: -

Actuation: Normally Open, Piping: Standard, Base Mounted, Voltage: 24 VDC, Electrical Entry: M Plug Connector, w/Lead Wire Length 300 mm, Light/Surge Voltage Suppressor: w/Light/Surge Voltage Suppressor, Manual Override: -, Port: -, Bracket: -

, m3 x 103, ft3, ft3 x 103, ft3 x 1060.1 to 1.5 MPa2.25 MPa20 kPa (at maximum flow rate)0 to 9,999,999,999 l?

, m3 x 103, ft3, ft3 x 103, ft3 x 1060.1 to 1.5 MPa2.25 MPa20 kPa (at maximum flow rate)0 to 9,999,999,999 l?

, m3 x 103, ft3, ft3 x 103, ft3 x 1060.1 to 1.5 MPa2.25 MPa20 kPa (at maximum flow rate)0 to 9,999,999,999 l?

Measurement mode Power is supplied Installation Press the SET button between 3 and 5 seconds Mounting by panel mount adapter Fix the panel mount adapter to the Controller with the set screws M3 x 8L (2 pcs.) as attached.

L/min. or CFM(ft3/min.) x 10-2 are the selectable display units. To use for flow rate indication, select the sensor and units before setting the functions [F1], [F2], [F4]. The set values for [F1], [F2] and [F4] will be reset when the flow indication setting is changed.

Mounting by panel mount adapter Fix the panel mount adapter to the controller by the mounting screws M3 x 8 L (2 pcs.).

, m3 x 103, ft3, ft3 x 103, ft3 x 1060.1 to 1.5 MPa2.25 MPa20 kPa (at maximum flow rate)0 to 9,999,999,999 l?

, m3 x 103, ft3, ft3 x 103, ft3 x 1060.1 to 1.5 MPa2.25 MPa20 kPa (at maximum flow rate)0 to 9,999,999,999 l?

, m3 x 103, ft3, ft3 x 103, ft3 x 1060.1 to 1.5 MPa2.25 MPa20 kPa (at maximum flow rate)0 to 9,999,999,999 l?

, m3 x 103, ft3, ft3 x 103, ft3 x 1060.1 to 1.5 MPa2.25 MPa20 kPa (at maximum flow rate)0 to 9,999,999,999 l?

, m3 x 103, ft3, ft3 x 103, ft3 x 1060.1 to 1.5 MPa2.25 MPa20 kPa (at maximum flow rate)0 to 9,999,999,999 l?

, m3 x 103, ft3, ft3 x 103, ft3 x 1060.1 to 1.5 MPa2.25 MPa20 kPa (at maximum flow rate)0 to 9,999,999,999 l?

, m3 x 103, ft3, ft3 x 103, ft3 x 1060.1 to 1.5 MPa2.25 MPa20 kPa (at maximum flow rate)0 to 9,999,999,999 l?

, m3 x 103, ft3, ft3 x 103, ft3 x 1060.1 to 1.5 MPa2.25 MPa20 kPa (at maximum flow rate)0 to 9,999,999,999 l?