AS2000-□-H, AS3000-□-H, AS4000-□-H, AS420-□-H, AS500-06-H, AS600-10-H, etc.
Low-temperature specification: the AS-□-L can be used from -30°C to 60°C.
Ex.) AS3000-□-L, AS4000-□-L, AS5000-□-L, AS420--L, AS500-06-L, AS600-10-L-, etc.
The AS series in-line type catalog can be found here.
Stations: 5 Stations, A, B Port: 06 (Side 3/4), SI Unit: QW (DeviceNet), P, R Port Size: 06 (3/4), P, R Port Location: D Side, Thread: T (NPTF)
Stations: 6 Stations, A, B Port: 06 (Side 3/4), SI Unit: QW (DeviceNet), P, R Port Size: 06 (3/4), P, R Port Location: D Side, Thread: T (NPTF)
Stations: 8 Stations, A, B Port: 06 (Side 3/4), SI Unit: QW (DeviceNet), P, R Port Size: 06 (3/4), P, R Port Location: D Side, Thread: T (NPTF)
Stations: 9 Stations, A, B Port: 06 (Side 3/4), SI Unit: QW (DeviceNet), P, R Port Size: 06 (3/4), P, R Port Location: D Side, Thread: T (NPTF)
Stations: 4 Stations, A, B Port: 06 (Side 3/4), SI Unit: 0 (w/o SI Unit), P, R Port Size: 06 (3/4), P, R Port Location: D Side, Thread: T (NPTF)
MB1 D-G5/K5/G5W/G5BA D-K59W, D-G59F, D-G5NT 20 to 100 D-C7/C8, D-C73C/C80C 20 to 63 CA2 CS1 Hs Hs CS2 24.5 16 A B B A D-B5/B6/B59W 20 to 100 D-H7/H7W D-H7NF/H7BA/D-H7C 20 to 63 Hs Hs 24.5 16 B A A B Auto Switch Mounting Height (mm) D-H7 D-H7W D-H7NF D-H7BA D-C7/C8 Auto switch model D-G5/K5 D-G5W D-K59W D-B5/B6 D-B59W D-M9(V) D-M9W(V) D-M9A(V) D-A9(V) D-G5NT D-G59F D-H7C D-G5BA D-C73C D-C80C
U side D side D D D D D D 3 2 1 Stations How to Order Solenoid Valve 10 SV 1 1 0 0 F 5 Note) Clean series Note) Available with manifold block for station additions. Refer to the WEB catalog.
) (in) D-B5 D-B6 D-C7 D-C80 D-C73C D-C80C D-B5 D-B6 D-C7 D-C80 D-C73C D-C80C D-B59W D-H7 D-H7C D-H7W D-H7BAL D-H7NF D-B59W D-H7 D-H7C D-H7W D-H7BAL D-H7NF D-H7LF D-G59 D-K59 D-H7LF D-G59 D-K59 Auto switch model Auto switch model B 0.42 0.31 0.52 0.51 0.56 0.83 B 0.86 0.59 0.76 0.85 0.75 1.20 A 0.94 0.78 1.00 1.23 1.13 1.58 A 0.94 0.78 1.00 1.23 1.13 1.58 B 0.50 0.39 0.60 0.59 0.64 0.91 B
D-H7W D-H7NF D-H7BA D-C7/C8 D-H7 D-H7C D-H7W D-H7BA D-H7NF D-G5/K5 D-G5W D-K59W D-B5/B6 D-B59W D-G5NT D-G59F D-H7C D-G5BA D-M9V D-M9WV D-M9AV D-A9V D-C7/C8 D-C73C D-C80C D-M9(V) D-M9W(V) D-M9A(V) D-C73C D-C80C D-B5 D-B6 D-B59W D-A9(V) A B A B A B A B A B A A B B 28.5 29 30.5 31 42.5 42.5 Hs 25.5 28 31.5 36 41.5 48.5 Hs 24.5 27 30.5 35 40.5 47.5 Hs 27 29.5 33 37.5 43 50 Hs 27.5 30
D-G5NTL 75 + 50 (n-2) 15 75 30.5 38 43 50 A B 0 (1) 0.5 2 2 D-A3 D-G3, D-K3 100 + 100 (n-2) 35 + 30 (n-2) 35 100 D-B5, D-B6 33.5 23.5 25 25 Approx. Hs 25.5 (28.5) 38 43.5 50.5 D-A4 35 + 30 (n-2) 50 + 50 (n-2) 35 55 A B 0 2 3.5 3.5 D-G5NTL 27 25 26.5 26.5 Approx. Hs 33.5 38 43.5 50.5 A B 0 1.5 1.5 D-A3 D-G3, D-K3 23 24.5 24.5 Approx.
Type Applicable cylinder series Auto switch model Applicable magnetic field Electrical entry Wiring (Pin no. in use) Lead wire length Applicable load Indicator light Load voltage D-P3DWASC D-P3DWASE D-P3DWA D-P3DWAL D-P3DWAZ D-P4DWSC D-P4DWSE D-P4DWL D-P4DWZ D-P79WSE D-P74L D-P74Z 2-wire (34) Pre-wired connector 0.3 m 2-wire (14) 0.5 m AC magnetic field (Single-phase AC welding magnetic field
D-G5NTL 75 + 50 (n-2) 15 75 30.5 38 43 50 A B 0 (1) 0.5 2 2 D-A3 D-G3, D-K3 100 + 100 (n-2) 35 + 30 (n-2) 35 100 D-B5, D-B6 33.5 23.5 25 25 Approx. Hs 25.5 (28.5) 38 43.5 50.5 D-A4 35 + 30 (n-2) 50 + 50 (n-2) 35 55 A B 0 2 3.5 3.5 D-G5NTL 27 25 26.5 26.5 Approx. Hs 33.5 38 43.5 50.5 A B 0 1.5 1.5 D-A3 D-G3, D-K3 23 24.5 24.5 Approx.
(Including band and screw) MVGQ Bore size (mm) 20 25 32 40 50 63 80 100 CC Applicable auto switch RB D-C7, D-C80 D-C73C, D-C80C Reed J BMA2-020 BMA2-032 BMA2-040 BMA2-050 BMA2-063 BMA2-025 D-H7/H7C D-H7W D-H7NF/H7BAL Solid state DD-B5, D-B64, D-B59W Reed -X D-G5/K59/G5W/K59W BA-04 BA-32 BA-05 BA-06 BA-01 BA-08 BA-10 BA-02 Solid state 20D-G5NTL, D-G5BAL D-A3, D-A44 Reed BD1-04M BD1-02 BD1
If 12VDC specifications are required, enter "12" at the end of the assembly part number. 1 2 1 2 P N D side SZ3000-40-6A-D For flat cable 20 pins SZ3000-40-5A-D 1 2 P N 1 2 D side SZ3000-40-8A-D For flat cable 10 pins SZ3000-40-7A-D A connector block assembly can be shipped as an assembly only in the case of double wiring.
A r-ll B T-l I t# r. r-1 zK 9K Flg. 8.25 Two cylinder cascade- P N E U M A T I C T E C H N O L O G Y APPENDIX SYMBOLS T H E S Y M B O L S F O R F L U I D P O W E R S Y S T E M S A N D C O M P O N E N T S A R E S T A N D A B D T Z E D I N I S O 1 2 1 9 . T H E S T A N D A R D C O M B T N E S H Y D R A U L I C A N D P N E U M A T I C C O M P O N E N T S .
Auto Switch Mounting Bore size Auto switch D-S5/S6/SS9W BA-04 SA-OS D-G5D IK59/G5 DWIK59W SA-OS SA-OB BA-lO 50 40 63 80 100 D-A5/A6IA59W D-FS D/JS D/FS DW/JS9W BT-04 BT-04 ST-06 ST-OB BT-OB D-FSNTL, FSSAL, FS9F O-A3/A44/G39/K39 BD1-04M BD1 -0SM SD1-0SM SOl-0BM SD1 -l0M D-GSSAUG59F/GSNTL D-A3 DC/A44C/G39CIK39C BA3-0S0 SA3-040 BA3-063 SA3-0BO BA3-100 D-A3 DCfA.44CfG39C/K39C: come With mounting
M a n i f o l d m o u n t e d v e r s i o n s o f t h e V YH y r e g a r e a v a i l a b l e .
A r-ll B T-l I t# r. r-1 zK 9K Flg. 8.25 Two cylinder cascade- P N E U M A T I C T E C H N O L O G Y APPENDIX SYMBOLS T H E S Y M B O L S F O R F L U I D P O W E R S Y S T E M S A N D C O M P O N E N T S A R E S T A N D A B D T Z E D I N I S O 1 2 1 9 . T H E S T A N D A R D C O M B T N E S H Y D R A U L I C A N D P N E U M A T I C C O M P O N E N T S .
G D G 24V 0V Power supply{ 24V 0V D G D G 24V 0V 24V 0V Power supply{ 24V 0V Power supply{ G D 0V 24V G D 0V 24V G D 0V 24V G D 0V 24V Transmission line Transmission line Black White Brown Blue Crimped connector SL-J1A Main transmission line Transmission line 24V 0V Power supply{ 24V 0V Power supply{ 24V 0V D G D G 24V 0V 24V 0V D G D G 24V 0V 24V 0V Power supply{ 24V 0V Power supply{ Special