Air Cylinder/Low Friction Type: Non-lube Type Series CS1Q Replacement Procedure is 125, 140 160 P.287 Construction Non-lube Actuators Modular F.R.L. Pressure Control Equipment Air Preparation Equipment Industrial Filters Replacement Procedure Actuators Modular F.R.L. Pressure Control Equipment Industrial Filters @6 @2 !8 @0@5 @3 @4 @1 !

CS2-125A-PS CS2-140A-PS CS2-160A-PS 125 140 160 !6 !7 !8 19 @0 21 Rod seal NBR Component part numbers: !6, !7, !8, @0. Cushion seal Urethane 19 and 21 are non-replaceable parts, so they are not included in the seal kit. Piston seal NBR Seal kit includes a grease pack (40 g). Order with the following part number when only the grease pack is needed.

Air Cylinder/Double Rod Construction Series CS2W 125, 140, 160 Replacement Procedure is P.287 Actuators Modular F.R.L. Pressure Control Equipment Air Preparation Equipment Industrial Filters Replacement Procedure Actuators Modular F.R.L. Pressure Control Equipment Industrial Filters !7 !4 !5 !8 !6 !

ZSE40 ISE40 3 0 3 0 3 0 ZSE10 ISE10 92 21 92 21 P P P T T T U U U E E E L L L S S S L L L 5.5 81 5.5 81 6 9 6 9 6 9 Setting dial ISE70 0.3 0.2 0.1 0.3 0.2 0.1 0.3 0.2 0.1 0 MPa 0.4 0 MPa 0.4 0 MPa 0.4 ZSE80 ISE80 12 12 12 Bracket ZSE ISE Plug Rc, NPT, G 1/8 SUP port 24 Pressure gauge L3 6.5 ZSP 24 36 36 PS n Stations 1 Left Right ISA2 ISA2 Stations L1 L2 L3 1 46 2 84 38 3 122 38 76 4 160

Circulating fluid flow rate [L/min] [m] [MPa] [m] [MPa] HRL300-Am-20 (CH1) HRL100/200/300-Am-20 (CH2) 0.9 0.6 90 60 0.8 80 0.5 50 0.7 70 Circulating fluid outlet 0.6 0.4 60 40 Usable flow rate range Circulating fluid outlet 0.5 50 0.3 30 0.4 40 0.3 0.2 30 20 Usable flow rate range 0.2 20 Circulating fluid return port Circulating fluid return port 0.1 10 0.1 10 0 0 0.0 0 0 20 40 60 80 100 120 140 160

Flow switch Refer to the Best Pneumatics No. 8 for details. 160 A Thermo-chiller Inverter Type HRSH Series Circulating Fluid Temperature Controller Communication function The serial communication (RS232C/RS485) and contact I/Os (2 inputs and 3 outputs) are equipped as standard. Communication with the users equipment and system construction are possible, depending on the application.

4 L2 35 L1 38 42 M plug connector (M) Air Preparation Equipment Pressure Control Equipment Flow Control Equipment Pressure Switches/ Pressure Sensors Stations 1 2 3 4 5 n D side U side Direct manual override (Non-locking) 24 15 43 L plug connector (L) n: Stations Dimensions n L 11 12 13 14 15 16 17 18 19 20 28 20 39 31 50 42 61 53 72 64 83 75 94 86 105 97 116 108 127 119 138 130 149 141 160

MPa) Delivery pressure (psig) 30 0.21 0.69 (17.5) 2.00 (50.8) 20 0.14 10 0.07 0.88 (22.4) 2 x 10-32 UNF depth 0.25 (6.3) (Mounting hole) 0 0.00 0 20 40 60 80 Flow rate (slpm, N2) AK1000HF 100 psig (0.69 MPa) 30 psig (0.21 MPa) Inlet pressure: 50 psig (0.34 MPa) 60 0.41 50 0.34 Delivery pressure (psig) Dlivery pressure (MPa) 40 0.28 30 0.21 20 0.14 10 0.07 0 0.00 0 20 40 60 80 100 120 140 160

66 17 10 218 80 22 10 218 80 19 10 241 90 25 10 241 90 21 10 277 100 30 10 334 150 40 13 13 16 16 19 19 22 22 32 100 63 113 76 119 76 145 90 151 90 166 106 173 106 200 122 253 160 8 12 6 40 66 84 28 5 2.0 27 37 1/4,3/8 172 AMH250 178 1/2 8 12 6 40 66 84 28 5 2.0 27 37 3/8, 1/2 204 AMH350 3/4 210 8 14 7 50 80 100 34 5 2.3 32 37 8 14 7 50 80 100 34 5 2.3 32 37 10 14 9 55 88 110 50 9 3.2 37

Size (Applicable vacuum pump) 100 (4B) JIS 10K FF flange Symbol Max. exhaust speed (L/min) 3 6 15 37 75 160 360 650 1,500 3,700 7,500 16,000 Specifications Oil mist removal Filtration Maximum operating temperature 99.5% or more 0.3 m (Trapping efficiency: 95%) 80C Model Model Connection R Max. air flow (L/min [ANR]) Applicable vacuum pump Max. exhaust speed (L/min) Weight (kg) Oil accumulation

151 6 131 122 188 179 7 150 141 216 207 8 169 160 244 235 9 188 179 272 263 10 207 198 300 291 L1 L2 L1 L2 ARM1000 PVQ ARM2000 VY1 VBA VBAT AP100 753

160, 180, 200, 250 0.7 AS800-12 1 4 35,400 1 540 38,500 586 1.4 AS900-14 1 2 52,000 1 792 47,500 724 300 3.3 AS900-20 57,800 2 880 60,800 926 3.3 Note) Flow rate values are measured at 0.5 MPa and 20C.

Bore sizes are available, depending on the series, from 20 to 160. Auto switches are available on most models.Tie-rod type low pressure hydraulic cylinder, Bore sizes *: 40, 50, 63, 80, 100, 125, 160, Standard strokes *: 25 to 1500, 3.5MPa, 8 mounting styles, Aluminum tube type is auto switch capable, CYL, HYDRAULIC, HYDRAULIC CYLINDER, CH, CC, HC

Bore sizes are available, depending on the series, from 20 to 160. Auto switches are available on most models.Tie-rod type low pressure hydraulic cylinder, Bore sizes *: 40, 50, 63, 80, 100, 125, 160, Standard strokes *: 25 to 1500, 3.5MPa, 8 mounting styles, Aluminum tube type is auto switch capable, CYL, HYDRAULIC, HYDRAULIC CYLINDER, CH, CC, HC

Air-hydro unit, series CC, Converter size (mm): 63, 100, 160, Small and large flow available, High cylinder operation speed, Air port size: 3/8 (63), 1/2 (100), 3/4 (160), Oil port size: 1/2 (63S, 100S), 3/4 (100L, 160L), AIR HYDRO UNIT, AIR HYDRO UNITS, CC, CCT, CCV

Bore sizes are available, depending on the series, from 20 to 160. Auto switches are available on most models.Tie-rod type low pressure hydraulic cylinder, Bore sizes *: 40, 50, 63, 80, 100, 125, 160, Standard strokes *: 25 to 1500, 3.5MPa, 8 mounting styles, Aluminum tube type is auto switch capable, ROD BOOT, CHA*50*K, HYDRAULIC CYLINDER, CH, CC, HC

Bore sizes are available, depending on the series, from 20 to 160. Auto switches are available on most models.Tie-rod type low pressure hydraulic cylinder, Bore sizes *: 40, 50, 63, 80, 100, 125, 160, Standard strokes *: 25 to 1500, 3.5MPa, 8 mounting styles, Aluminum tube type is auto switch capable, CYL, AIR-HYDRO, AUTO-SW, HYDRAULIC CYLINDER, CH, CC, HC

Bore sizes are available, depending on the series, from 20 to 160. Auto switches are available on most models.Tie-rod type low pressure hydraulic cylinder, Bore sizes *: 40, 50, 63, 80, 100, 125, 160, Standard strokes *: 25 to 1500, 3.5MPa, 8 mounting styles, Aluminum tube type is auto switch capable, CYL, HYDRAULIC, HYDRAULIC CYLINDER, CH, CC, HC

Air-hydro unit, series CC, Converter size (mm): 63, 100, 160, Small and large flow available, High cylinder operation speed, Air port size: 3/8 (63), 1/2 (100), 3/4 (160), Oil port size: 1/2 (63S, 100S), 3/4 (100L, 160L), AIR HYDRO UNIT, AIR HYDRO UNITS, CC, CCT, CCV

Air-hydro unit, series CC, Converter size (mm): 63, 100, 160, Small and large flow available, High cylinder operation speed, Air port size: 3/8 (63), 1/2 (100), 3/4 (160), Oil port size: 1/2 (63S, 100S), 3/4 (100L, 160L), AIR HYDRO UNIT, AIR HYDRO UNITS, CC, CCT, CCV