Piping Specifications: NPT1/8 Piping Adapter, Side Ported, Output Specifications: PNP Open Collector 2 Outputs, Unit Specifications: Unit Switching Function (Not Allowed for Use in Japan), Lead Wire: G [Lead Wire w/Connector (2m Lead Wire Length)+Connector Cover], Adapter: None, Calibration Certification: w/Certificate
Piping Specifications: NPT1/8 Piping Adapter, Side Ported, Output Specifications: PNP Open Collector 2 Outputs, Unit Specifications: Unit Switching Function, Initial Value psi, Not Allowed for Use in Japan, Lead Wire: G [Lead Wire w/Connector (2m Lead Wire Length)+Connector Cover], Adapter: None, Calibration Certification: w/Certificate
Piping Specifications: M5 Female Thread/Side Piping Port, Output Specifications: PNP Open Collector 2 Outputs, Unit Specifications: Fixed SI Unit, kPa, Lead Wire: No Lead Wire, Adapter: R [DIN Rail Adapter (DIN Rail to be Prepared by Customer)], Calibration Certification: -
Piping Specifications: M5 Female Thread/Side Piping Port, Output Specifications: PNP Open Collector 2 Outputs, Unit Specifications: Unit Switching Function (Not Allowed for Use in Japan), Lead Wire: No Lead Wire, Adapter: None, Calibration Certification: w/Certificate
Piping Specifications: M5 Female Thread/Rear Piping Port, Output Specifications: PNP Open Collector 2 Outputs, Unit Specifications: Unit Switching Function (Not Allowed for Use in Japan), Lead Wire: G [Lead Wire w/Connector (2m Lead Wire Length)+Connector Cover], Adapter: Panel Mount Adapter+Front Protective Cover, Calibration Certification: w/Certificate
Piping Specifications: M5 Female Thread/Side Piping Port, Output Specifications: PNP Open Collector 2 Outputs, Unit Specifications: Unit Switching Function, Initial Value psi, Not Allowed for Use in Japan, Lead Wire: G [Lead Wire w/Connector (2m Lead Wire Length)+Connector Cover], Adapter: None, Calibration Certification: w/Certificate
Piping Specifications: M5 Female Thread/Side Piping Port, Output Specifications: PNP Open Collector 2 Outputs, Unit Specifications: Fixed SI Unit, kPa, Lead Wire: G [Lead Wire w/Connector (2m Lead Wire Length)+Connector Cover], Adapter: Panel Mount Adapter+Front Protective Cover, Calibration Certification: -
Piping Specifications: M5 Female Thread/Rear Piping Port, Output Specifications: PNP Open Collector 2 Outputs, Unit Specifications: Fixed SI Unit, kPa, Lead Wire: G [Lead Wire w/Connector (2m Lead Wire Length)+Connector Cover], Adapter: Panel Mount Adapter+Front Protective Cover, Calibration Certification: -
NPN 1 output ISE30A-01-N-ML Digital pressure PNP 1 output ISE30A-01-P-ML NPN 1 output/ Voltage output ISE30A-01-C-ML switch Note 3) NPN 1 output/ Current output ISE30A-01-D-ML Note 1) This is an assembly of the bracket and resin panel nut. Note 2) l in part numbers for a round type pressure gauge indicates a type of connection thread.
The output goes OFF when "B" is turned ON in condition 2. Interlock circuit When either "A" or "B" are ON, output 3 does not go ON even if "C" is turned ON. Output 3 goes ON if "C" is turned ON, only when both "A" and "B" are OFF. OR circuit The cylinder operates if either "A" or "B" is ON.
The output goes OFF when "B" is turned ON in condition 2. Interlock circuit When either "A" or "B" are ON, output 3 does not go ON even if "C" is turned ON. Output 3 goes ON if "C" is turned ON, only when both "A" and "B" are OFF . OR circuit The cylinder operates if either "A" or "B" is ON.
Body Size: 20, Thread: Rc (Rc: for Sizes 20, 25, 30, 40; M5: for Size 10), Port Size: 01 (1/8), Option: BM (B + M), Semi-Standard: R (Flow Direction: Right to Left)
Body Size: 20, Thread: N (NPT), Port Size: 01 (1/8), Option: BM (B + M), Semi-Standard: Z (Name Plate & Pressure Gauge in Imperial Units: psi, °F)
Rated Vacuum Range: -101 to 0 kPa, Output Specification: S (NPN Open Collector 2 Outputs + Analog Current Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: 01 (R 1/8), Lead Wire: J (Lead Wire w/Connector, 5-core, 2 m Lead Wire), Bracket: A2 (Bracket B, Horizontal Mounting)
Controller Mounting: D (DIN Rail Mouting), Cable Length: 1 (1 m), Inlet Port Silencer: B (ANB1-01, 55 dB)
Indicator: S, Control Range: M (1 to 50mm/s), Control Method: E (Meter-out), Stud Position: B (Left Side), Tube Diameter: 03 (ø5/32"), Thread: N (NPT), Port Size: 01 (1/8), Seal Method: S (w/Sealant)
Output Specification: T (PNP Open Collector 2 Outputs + Analog Voltage Output), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: 01 (R 1/8), Lead Wire: J (Lead Wire w/Connector, 5-core, 2 m Lead Wire), Bracket: B (Panel Mount Adapter), Operation Manual: K (Operation Manual, Calibration Certificate)
Output Specification: V (PNP Open Collector 2 Outputs + Analog Current Output), Unit Specification: P (Unit Selection Function, Initial value psi), Piping Specification: 01 (R 1/8), Lead Wire: W (Lead Wire w/Connector, 5-core, 2 m Lead Wire, Waterproof), Bracket: B (Panel Mount Adapter)
Type of Actuation: 2 (2 Position Double), Manifold Type: 40 (Base Mounted Non Plug-in Single/Stacking Base, Plug-in Stacking Base), Pilot: Internal Pilot, Specifications: Standard, Voltage: 5 (24VDC), Electrical Entry: MO (M Plug w/o Connector), Lead Wire Length: None, Surge Suppressor: Z (Light & Surge Suppressor), Manual Override: Non-locking Push Style, A, B Port Size: 01 (Base Mounted
Type of Actuation: 1 (2 Position Single), Manifold Type: 20 (Body Ported Plug-in Integrated), Pilot: Internal Pilot, Specifications: Standard, Voltage: 6 (12VDC), Electrical Entry: MN (M Plug Connector w/o Lead Wire), Lead Wire Length: None, Surge Suppressor: None, Manual Override: Non-locking Push Style, A, B Port Size: 01 (Body Ported 1/8), Thread: N (NPT)