SMC Corporation of America
Elite Part Number Search
Search Results "ISE20A-V-01-A1"

Power and output connector pin numbers (on the lead wire) Wire colour Description Brown DC(+) Black OUT1 White OUT2 Grey Analogue output/External input Blue DC(-) -16No.PF-OMJ0018-F Internal circuit and wiring example PFM30 NPN (2 outputs) + Analogue (1 to 5 V) output type Max. 30 V, 80 mA Internal voltage drop: 1 V or less Analogue output: 1 to 5 V Output impedance: approx. 1 k PFM31 NPN

LQ LVN Table(1) Connection Size and Applicable Model Table(2) Rated Voltage-Electrical Entry-Electrical Option Insulation type Electrical entry Electrical option 1 (100 V) 2 (200 V) 3 (110 V) 4 (220 V) 7 (240 V) 8 (48 V) 5 (24 V) 6 (12 V) TI/ TIL Applicable model VXR2150-04 VXR2150-06 VXR2260-10 1 VXR2270-12 1 VXR2380-14 2 VXR2390-20 Size Class B Class H G PA 1 2 3 4 C D, T G, C T S L,

Input voltage 1 V 5 V The sensor input range can be set to the required value and displayed. (Voltage input: 1 to 5 V) Pressure switch/Flow switch can be displayed. M For Flow Sensor / PFMV5 Setting of the display for analog voltage A is displayed for 1 V. B is displayed for 5 V. The range can be set as required.

Designation Description 1 SV24 V +24 V for solenoid valve 2 SV0 V 0 V for solenoid valve 3 SI24 V +24 V for SI unit operation 4 SI0 V 0 V for SI unit operation 5 Unused The M12 connector cable has two types, SPEEDCON compatible and non-compatible.

Nil Without restrictor With restrictor S Digital flow switch ON/OFF valve Nil Without digital flow switch NPN open collector 1 output + Analog output (1 to 5 V) PNP open collector 1 output + Analog output (1 to 5 V) NPN open collector 2 outputs PNP open collector 2 outputs NPN open collector 1 output + Analog output (4 to 20 mA) PNP open collector 1 output + Analog output (4 to 20 mA) P1

motor power supply input terminal (U, V, W) to the driver power terminal (U, V, W) Connect the motor ground terminal to the driver ground terminal.

PSE532 PSE533 01 MPa 0-101 kPa 0101 kPa -101101 kPa -0.10 MPa 10.10 kPa -10.10 kPa 1.5 MPa 500 kPa DC1224 V10%(p-p)10%() 15 mA () DC15 V() DC0.61 V() 1 k (25 ) 2%F.S.(),5%F.S.() 1%F.S. 1%F.S.

Connecting a servo motor of the wrong axis to U, V, W, or CN2 of the driver may cause a malfunction. 12. The illustration of the 24 V DC power supply is divided between input signal and output signal for convenience. However, they can be configured by one. -6- (2) Using 1-phase 200 V AC to 240 V AC power supply for LECSN2-T Note 1. Between P3 and P4 is connected by default. 2.

power supply input terminal (U, V, W) to the driver power terminal (U, V, W) Connect the motor ground terminal to the driver ground terminal.

Alarm code Alarm message Operation status Main reason 01 Liquid deposits in the base of this unit.

Output Specification: V (PNP Open Collector 2 Outputs + Analog Current Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: M5 (Female Thread)

Output Specification: V (PNP Open Collector 2 Outputs + Analog Current Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: C4L (ø4 One-touch Fitting, Elbow Type)

Output Specification: V (PNP Open Collector 2 Outputs + Analog Current Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: N01 (NPT 1/8)

Output Specification: V (PNP Open Collector 2 Outputs + Analog Current Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: N7L (ø1/4" One-touch Fitting, Elbow Type)

Output Specification: V (PNP Open Collector 2 Outputs + Analog Current Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: N7H (ø1/4" One-touch Fitting, Straight Type)

Output Specification: V (PNP Open Collector 2 Outputs + Analog Current Output), Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: C6L (ø6 One-touch Fitting, Elbow Type)

Output Specification: PNP Open Collector 2 Outputs + Analog Current Output, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: Female Thread, Lead Wire: -, Bracket: -, Operation Manual: -

Output Specification: PNP Open Collector 2 Outputs + Analog Current Output, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: ø4 One-touch Fitting, Elbow Type, Lead Wire: -, Bracket: -, Operation Manual: -

Output Specification: PNP Open Collector 2 Outputs + Analog Current Output, Unit Specification: Unit Selection Function, Switches w/Unit Selection not Permitted for Use in Japan, Piping Specification: NPT 1/8, Lead Wire: -, Bracket: -, Operation Manual: -