SMC Corporation of America
Elite Part Number Search
Search Results "ISE20B-L-P-M5-A2"

](mgCaCO3/L) 100 or less 50 or less 50 or less Total hardness (mgCaCO3/L) 200 or less 70 or less 70 or less Calcium hardness (mgCaCO3/L) 150 or less 50 or less 50 or less Ionic state silica (mgSiO2/L) 50 or less 30 or less 30 or less Iron (mg/L) 1.0 or less 0.3 or less 1.0 or less Copper (mg/L) 0.3 or less 0.1 or less 1.0 or less Reference items Sulfide ions (mg/L) Shall not be detected.

](mgCaCO3/L) 100 or less 50 or less 50 or less Total hardness (mgCaCO3/L) 200 or less 70 or less 70 or less Calcium hardness (mgCaCO3/L) 150 or less 50 or less 50 or less Ionic state silica (mgSiO2/L) 50 or less 30 or less 30 or less Iron (mg/L) 1.0 or less 0.3 or less 1.0 or less Copper (mg/L) 0.3 or less 0.1 or less 1.0 or less Reference items Sulfide ions (mg/L) Shall not be detected.

x 0.8 depth 7.5 M5 x 0.8 depth 6 Width across flats 8 length 3.5 M10 x 1.25 27 25 8 6.5 M5 x 0.8 32 17.5 15 17 20 10 18 0 0.1 2 24 6 M5 x 0.8 depth 8 M5 x 0.8 depth 6 Width across flats 8 length 3.5 M10 x 1.25 34.5 32 12 6.5 M5 x 0.8 40 23.5 20.5 22 24 14 24 0 0.1 2 30 8 M6 x 1 depth 10 M6 x 1 depth 7 Width across flats 12 length 3.5 M14 x 1.5 42.5 40 13 6.5 M8 x 1.25 [mm] [mm] Port Thread

D-A9V/M9V/M9WV/D-M9A(V)L types cannot be mounted. Do not indicate suffix N for no lead wire on D-A3/A44/G39/K39 models. Lead wire length symbols: 0.5 mNil (Example) M9NW 1 m M (Example) M9NWM 3 m L (Example) M9NWL 5 m Z (Example) M9NWZ None N (Example) H7CN -X Individual -X Since there are other applicable auto switches than listed, refer to page 1214 for details.

min or less 12 L/min or less 22 L/min or less Power supply voltage 24 VDC 10%, Ripple(p-p) 10% or less (with power supply polarity protection) Current consumption 25 mA or less Switch output 1 output (NPN or PNP) Max. load current 10 mA Max. applied voltage 26.4 V Residual voltage 1 V or less (at 10 mA) Short circuit protection Provided Repeatability 0.005 mm or less 0.010 mm or less 0.020

B Counter bore depth C 4-LD Thread depth M QW PB N A E depth EK Q + Stroke Z + Stroke G A A LW Stroke adjustment screw (inner cover) Note 2) Note 3) Note 2) Operating direction Plug [P (port g)] Plug [P (port h)] P (port a) P (port b) 0.5 0.5 Plug [P (port c)] Plug [P (port e)] Left Right Auto switch mounting groove HI HP H HL HG HT HS HB HA HB HA HG HT HI Note 3) Plug [P (port d)] Plug [

Note 2) Contact P/A if a stroke greater than the maximum stroke is desired.

4 20: M5 x 0.8 x 6 25, 32: M6 x 1 x 6 40: M8 x 1.25 x 8 Nickel plated Carbon steel Hexagon socket head cap screw !5 20, 25: M5 x 0.8 x 6 32, 40: M6 x 1 x 8 Carbon steel Hexagon socket head set screw !6 Nickel plated !7 Plate Special resin !8 Cushion seal NBR !9 Piston seal Replacement Parts Resin @0 Wear ring NBR Bore size (mm) Kit no.

Refer to Chapter 3, Product Specific Precautions 3 (P. 7 to 8) and Chapter 5, Construction and Dimensions (P. 11) for maintenance parts. Parts with the indication of "Maintenance part" can be replaced. 4. SMC specified parts should be used for service. Refer to the Construction / Maintenance parts table. 5.

A B d H Model H A SN-015A M14 x 1 19 21.9 5 ZPNA-M16 M16 x 1.5 22 25.4 6 ZPNA-M18 M18 x 1.5 27 31.2 9 ZPNA-M22 M22 x 1.5 30 34.6 8 Bolts (Hexagonal Socket Head Cap Screw) Dimensions d B (mm) A B d L 8 11 5.5 M3 x 0.5 L 8 12 7 M4 x 0.7 A 10 15 8.5 M5 x 0.8 13-11-96

VCB F N G Coil type NPT G Grommet / Tape winding W Grommet / Molded VCL Port size VCS Port size Symbol Series 20 p p 30 10 p VCW M5 01 02 p p M5 1/8 (6A) 1/4 (8A) Magnet wire protection: Tape winding Magnet wire protection: Resin Molded Orifice diameter F Faston terminal / Molded Orifice diameter (mm ) Symbol Series 1 2 1 2 3 2 3 4 1 10 1.6 1.6 2.3 20 3.2 2 Magnet wire protection:

Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: P [Units Selection Function (Initial Value psi)], Under New Measurement Act Selection Function not Permitted for use in Japan, Piping Specification: N01 (NPT1/8), Connector Type: S (M12 Connector Type), Bracket: None, Operation Manual: Y (w/o Operation Manual, w/o Calibration Certificate)

Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: P [Units Selection Function (Initial Value psi)], Under New Measurement Act Selection Function not Permitted for use in Japan, Piping Specification: N01 (NPT1/8), Lead Wire: W (Lead Wire w/Connector, 5-core, 2m Lead Wire w/Waterproof Cover)

Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: P [Units Selection Function (Initial Value psi)], Under New Measurement Act Selection Function not Permitted for use in Japan, Piping Specification: N01 (NPT1/8), Lead Wire: w/o Lead Wire, Bracket: A1 [Bracket A, Vertical Mounting (ZS-46-A1)]

Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: P [Units Selection Function (Initial Value psi)], Under New Measurement Act Selection Function not Permitted for use in Japan, Piping Specification: N01 (NPT1/8), Lead Wire: W (Lead Wire w/Connector, 5-core, 2m Lead Wire w/Waterproof Cover), Bracket: A1 [Bracket A, Vertical Mounting (ZS-46-A1)]

Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: P [Units Selection Function (Initial Value psi)], Under New Measurement Act Selection Function not Permitted for use in Japan, Piping Specification: N01 (NPT1/8), Lead Wire: W (Lead Wire w/Connector, 5-core, 2m Lead Wire w/Waterproof Cover), Bracket: A2 [Bracket B, Horizontal Mounting (ZS-46-A2)]

Output Specification: IO-Link/Switch: 1 Output, PNP or NPN, Unit Specification: P [Units Selection Function (Initial Value psi)], Under New Measurement Act Selection Function not Permitted for use in Japan, Piping Specification: N01 (NPT1/8), Lead Wire: W (Lead Wire w/Connector, 5-core, 2m Lead Wire w/Waterproof Cover), Bracket: B [Panel Mount Adapter, (ZS-46-B)]